Name: | CREATIVE MODELING & DESIGN, LLC |
Jurisdiction: | Rhode Island |
Entity type: | Domestic Limited Liability Company |
Status: | Activ |
Date of Organization in Rhode Island: | 05 Dec 2008 (16 years ago) |
Identification Number: | 000487681 |
ZIP code: | 02919 |
County: | Providence County |
Principal Address: | 16 SUNNYSIDE AVENUE, JOHNSTON, RI, 02919, USA |
Mailing Address: | 16 SUNNYSIDE AVENUE, JOHNSTON, RI, 02917, USA |
Purpose: | MANUFACTURING AND SALE OF PRODUCTS IN METAL FORM |
NAICS
339999 All Other Miscellaneous ManufacturingThis U.S. industry comprises establishments primarily engaged in miscellaneous manufacturing (except medical equipment and supplies, jewelry and flatware, sporting and athletic goods, dolls, toys, games, office supplies (except paper), musical instruments, fasteners, buttons, needles, pins, brooms, brushes, mops, and burial caskets). Learn more at the U.S. Census Bureau
Name | Role | Address |
---|---|---|
JEAN FALLAGO, ESQ. | Agent | 132B PLEASANT VIEW AVENUE, SMITHFIELD, RI, 02917, USA |
Number | Name | File Date |
---|---|---|
202451299060 | Annual Report | 2024-04-17 |
202334515920 | Annual Report | 2023-04-28 |
202211386250 | Annual Report | 2022-02-22 |
202104382730 | Annual Report | 2021-11-01 |
202071881010 | Annual Report | 2020-10-29 |
201925658680 | Annual Report | 2019-10-25 |
201880457920 | Annual Report | 2018-10-29 |
201753913720 | Annual Report | 2017-11-24 |
201611377950 | Annual Report | 2016-10-28 |
201579733030 | Annual Report | 2015-09-18 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340496116 | 0112300 | 2015-03-27 | 16 SUNNYSIDE AVENUE, JOHNSTON, RI, 02919 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 972094 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100217 B04 I |
Issuance Date | 2015-09-18 |
Current Penalty | 1200.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-10-05 |
Nr Instances | 3 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals: (a) Mechanical Power Press Area: The foot pedal mechanisms on three presses were not provided with adequate protection to prevent unintended operation. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19100217 B06 I |
Issuance Date | 2015-09-18 |
Current Penalty | 1200.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-10-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.217(b)(6)(i): Two hand trip(s) on mechanical power press(es) using full revolution clutches did not have the individual operator's hand controls arranged by design and construction and/or separation to require the use of both hands to trip the press: (a) Mechanical Power Press Area: The two hand trips on the Federal Press number 2 were not adequately arranged in distance so that both hand were needed to trip in that they were 23 inches apart allowing one hand to operate both buttons. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19100217 C03 I E |
Issuance Date | 2015-09-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-10-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.217(c)(3)(i)(e): The location of the hand controls did not allow a safe distance from the point of operation so that the slide completes the downward travel or stops before the operator can reach into the point of operation with his hands: (a) Mechanical Power Press Area: The location of the two hand trip controls on Press number 2 did not allow a safe distance from the point of operation in that they were only 14 1/2 inches from the point of operation and the operator could reach the point of operation during the downward travel of the slide. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100217 C01 I |
Issuance Date | 2015-09-18 |
Current Penalty | 1680.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-10-05 |
Nr Instances | 4 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es): (a) Mechanical Power Press Area: On or about 03/27/2015, the four mechanical power presses being run in the continuous mode were not provided with adequate point of operation guarding and/or guarding devices. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100217 E01 I |
Issuance Date | 2015-09-18 |
Abatement Due Date | 2015-10-13 |
Current Penalty | 1680.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-10-05 |
Nr Instances | 4 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: (a) Mechanical Power Press Area: On or about 03/27/2015, the employer had not established nor implemented a program of periodic and regular inspection for all of the mechanical power presses within the establishment. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8253507105 | 2020-04-15 | 0165 | PPP | 16 SUNNYSIDE AVE, JOHNSTON, RI, 02919 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 13 Oct 2024