Search icon

S&A Holdings, Inc.

Company Details

Name: S&A Holdings, Inc.
Jurisdiction: Rhode Island
Entity type: Domestic Profit Corporation
Status: Activ
Date of Organization in Rhode Island: 28 Aug 2009 (16 years ago)
Identification Number: 000509826
ZIP code: 02888
County: Kent County
Principal Address: 221 JEFFERSON BOULEVARD, WARWICK, RI, 02888, USA
Purpose: SIGNS AND AWNINGS MANUFACTURE AND SERVICE Title: 7-1.2-1701
Fictitious names: MID-CITY Wholesale Signs (trading name, 2014-03-20 - 2023-07-19)
Signs & Awnings (trading name, 2013-10-03 - 2023-07-19)
Darlington Awning & Neon (trading name, 2013-10-03 - 2023-07-19)
Centredale Sign (trading name, 2013-10-03 - 2023-07-19)
AA Thrifty Sign & Awning (trading name, 2013-10-03 - 2023-07-19)
AA Thrifty Sign and Awning (trading name, 2010-04-09 - 2011-07-22)
Awning Factory (trading name, 2010-04-09 - 2023-07-19)
Historical names: Signs & Awnings, Inc.

Industry & Business Activity

NAICS

339999 All Other Miscellaneous Manufacturing

This U.S. industry comprises establishments primarily engaged in miscellaneous manufacturing (except medical equipment and supplies, jewelry and flatware, sporting and athletic goods, dolls, toys, games, office supplies (except paper), musical instruments, fasteners, buttons, needles, pins, brooms, brushes, mops, and burial caskets). Learn more at the U.S. Census Bureau

Agent

Name Role Address
JAMES R SIMMONS, ESQ. Agent 4 RICHMOND SQUARE SUITE 102, PROVIDENCE, RI, 02906, USA

PRESIDENT

Name Role Address
GEORGE C. DAUBMANN PRESIDENT 8897 S.E. MARINA BAY DRIVE HOBE SOUND, FL 33455 USA

Events

Type Date Old Value New Value
Name Change 2011-07-22 Signs & Awnings, Inc. S&A Holdings, Inc.

Filings

Number Name File Date
202445831520 Annual Report 2024-02-07
202342833500 Statement of Change of Registered/Resident Agent Office 2023-11-20
202339598270 Statement of Abandonment of Use of Fictitious Business Name 2023-07-19
202339598090 Statement of Abandonment of Use of Fictitious Business Name 2023-07-19
202339597660 Statement of Abandonment of Use of Fictitious Business Name 2023-07-19
202339597570 Statement of Abandonment of Use of Fictitious Business Name 2023-07-19
202339597200 Statement of Abandonment of Use of Fictitious Business Name 2023-07-19
202339596690 Statement of Abandonment of Use of Fictitious Business Name 2023-07-19
202327746270 Annual Report 2023-02-07
202213010810 Annual Report 2022-03-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343302386 0112300 2018-07-17 221 JEFFERSON BOULEVARD, WARWICK, RI, 02888
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2018-07-17
Emphasis L: CRANE
Case Closed 2020-11-13

Related Activity

Type Complaint
Activity Nr 1358742
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100107 B01
Issuance Date 2018-10-22
Abatement Due Date 2020-03-31
Current Penalty 1108.75
Initial Penalty 3696.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(1): The spray booth was not substantially constructed of steel, securely and rigidly supported, or of concrete or masonry. Facility: On or about July 17, 2018 and at times prior thereto the spray booth was constructed of wall board and not substantially constructed of steel, concrete or masonry.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100107 B05 I
Issuance Date 2018-10-22
Abatement Due Date 2020-03-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(5)(i): The spraying operations (except electrostatic spraying operations) were not designed, installed and maintained such that the average air velocity over the open face of the booth (or booth cross section during spraying operations) was not less than 100 linear feet per minute. Visible gauges or audible alarms or pressure activated devices were not installed to indicate or insure that the required air velocity was maintained. Filter rolls were not inspected to insure proper replacement of filter media. Facility: On or about July 17, 2018 the employer did not ensure the spray booth system's effectiveness in controlling the airborne hazards from spray painting operations: (1) Air flow measurements indicated that the cross-sectional air flow during spray painting operations in the dry type spray paint booth was less than the 100 linear feet per minute. Measurements taken on August 29, 2018 indicated that the average air velocity across the face of the booth was 10.5 linear feet per minute (fpm). (2) The employer did not ensure visible gauges or audible alarms or pressure activated devices were installed to indicate or insure that the required air velocity was maintained.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100107 B05 IV
Issuance Date 2018-10-22
Abatement Due Date 2020-03-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: Facility: On or about July 17, 2018 the space within the spray booth on the downstream side of the filters did not have automatic sprinklers installed to protect employees from fire hazards.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100107 D11
Issuance Date 2018-10-22
Abatement Due Date 2020-03-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(d)(11): Air intake openings to rooms containing spray finishing operations were not adequate for the efficient operation of exhaust fans and were not located as to minimize the creation of dead air pockets: Facility: On or about July 17, 2018 the employer did not ensure air intake openings to rooms containing spray finishing operations were adequate for the efficient operation of exhaust fans and were located as to minimize the creation of dead air pockets.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100132 D01
Issuance Date 2018-10-22
Abatement Due Date 2019-10-15
Current Penalty 1108.75
Initial Penalty 3696.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): Facility: On or about July 17, 2018 the employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE) such as gloves for employees that use Cooley Magic which contains methylene chloride.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100132 D02
Issuance Date 2018-10-22
Abatement Due Date 2019-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 23
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: Facility: On or about July 17, 2018 employees working throughout the facility were exposed to hazards including but not limited to welding, methylene chloride and spray painting operations and the employer had not certified that a workplace hazard assessment had been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19101052 D02
Issuance Date 2018-10-22
Abatement Due Date 2019-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1052(d)(2): The employer did not perform initial monitoring to determine each employee's exposure to methylene chloride: Facilty: On or about July17, 2018 the employer did not perform initial monitoring to determine each employee's exposure to methylene chloride for the employees that use Cooley Magic which contains methylene chloride at greater than 60%.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2018-10-22
Abatement Due Date 2019-10-15
Current Penalty 1108.75
Initial Penalty 3696.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Facility: On or about July 17, 2018 the employer did not establish and implement a written respiratory protection program in accordance with 29 CFR 1910.134(c)(l) that would describe or include at least the following: 1) Procedures for selecting respirators; 2) Worksite specific procedures; 3) Medical evaluations; 4) Fit testing procedures; 5) Procedures for proper use of respirators in routine and reasonably foreseeable emergency; 6) Procedures and schedules for cleaning, storing, inspecting, repairing and discarding respirators; 7) Employee training regarding respiratory hazards they are exposed to, proper use and limitations of respirators; and 8) Procedures for regularly evaluating the effectiveness of the respirator program The employer required of the employee(s) assigned to painting operations to wear respiratory protection. The painter used elastomeric half-faced 3M 7500 series respirator equipped with Organic Vapor/ P100 cartridges. The employer did not ensure that where respirators were required, a written respiratory protection program was established, implemented and maintained.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100134 F02
Issuance Date 2018-10-22
Abatement Due Date 2019-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: Facility: On or about July 17, 2018 the employer did not ensure that fit tests were completed at least annually for employees that wear respirators for protection from inhalation hazards while spray painting and welding.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19100134 K01
Issuance Date 2018-10-22
Abatement Due Date 2019-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: Facility: On or about July 17, 2018 the employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary for employees that work in the painting department and wear a 3M 7503 half-faced respirator for painting operations.
Citation ID 01003D
Citaton Type Serious
Standard Cited 19100134 K06
Issuance Date 2018-10-22
Abatement Due Date 2019-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: Facility: On or about July 17, 2018 the employer did not provide the basic advisory information to an employee in the fabrication area on respirators used while welding, as presented in Appendix D of 29 CPR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100141 G02
Issuance Date 2018-10-22
Abatement Due Date 2019-10-15
Current Penalty 1108.75
Initial Penalty 3696.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(g)(2): Employees were permitted to consume food or beverage in area(s) exposed to toxic materials: Facility: On or about July 17, 2018 the employer permitted employees to consume food or beverage in the paint preparation area(s) exposed to toxic materials such as paint and paint related materials including but not limited to Matthews Accelerator 287437SP, Matthews Catalyst 43270SP, Matthews Reducer 45280SP and Matthews Blue N920SP which could effect the central nervous system.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2018-10-22
Abatement Due Date 2019-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Facility: On or about July 17, 2018 and at times prior thereto, the employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met for chemicals used by employees in the shop area, such as but not limited to methylene chloride and toluene which target the central nervous system.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19101200 G01
Issuance Date 2018-10-22
Abatement Due Date 2019-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: Facility: On or about July 17, 2018 and at times prior thereto the employer did not have a material safety data sheet for each hazardous chemical in use such as AMTECH 600-1 and 5 Star Xtreme High Build 2K DTM Primer/Filler/Sealer.
Citation ID 02001A
Citaton Type Other
Standard Cited 19261412 F01
Issuance Date 2018-10-22
Abatement Due Date 2019-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1412(f)(1): 29 CFR 1926.1412(f)(1): The equipment was not inspected at least every 12 months by a qualified person in accordance with paragraph (d) of this section. Facility: On or about July 17, 2018 the annual inspection of cranes including but not limited to the Elliott L60 was not performed in accordance with standard. All required inspections were not performed and documented.

Date of last update: 14 Oct 2024

Sources: Rhode Island Department of State