Search icon

Vemaline Products Inc.

Company Details

Name: Vemaline Products Inc.
Jurisdiction: Rhode Island
Entity type: Domestic Profit Corporation
Status: Activ
Date of Organization in Rhode Island: 19 Nov 2009 (15 years ago)
Identification Number: 000519131
ZIP code: 02910
County: Providence County
Principal Address: 200 1ST AVENUE, CRANSTON, RI, 02910, USA
Purpose: THE DESIGN, MANUFACTURE AND SALE OF PULLS, HANDLES AND KNOBS. Title: 7-1.2-1701
Fictitious names: Vemaline (trading name, 2009-12-31 - )
Handles Unlimited (trading name, 2009-12-31 - )
Historical names: Vemaline Products Inc.
Vemaline Products Acquisition Inc.

Industry & Business Activity

NAICS

339999 All Other Miscellaneous Manufacturing

This U.S. industry comprises establishments primarily engaged in miscellaneous manufacturing (except medical equipment and supplies, jewelry and flatware, sporting and athletic goods, dolls, toys, games, office supplies (except paper), musical instruments, fasteners, buttons, needles, pins, brooms, brushes, mops, and burial caskets). Learn more at the U.S. Census Bureau

Agent

Name Role Address
JEFFREY B. CIANCIOLO, ESQ. Agent 148 WEST RIVER STREET SUITE 1E, PROVIDENCE, RI, 02904, USA

PRESIDENT

Name Role Address
JEFFREY PANEK PRESIDENT 112 DILLABUR AVENUE NORTH KINGSTOWN, RI 02852 USA

SECRETARY

Name Role Address
JEFFREY PANEK SECRETARY 112 DILLABUR AVENUE NORTH KINGSTOWN, RI 02852 USA

TREASURER

Name Role Address
JEFFREY PANEK TREASURER 112 DILLABUR AVENUE NORTH KINGSTOWN, RI 02852 USA

Events

Type Date Old Value New Value
Name Change 2009-12-31 Vemaline Products Acquisition Inc. Vemaline Products Inc.
Name Change 2009-11-23 Vemaline Products Inc. Vemaline Products Acquisition Inc.

Filings

Number Name File Date
202450154720 Annual Report 2024-04-04
202333328080 Annual Report 2023-04-19
202216104480 Annual Report 2022-04-28
202192630980 Annual Report 2021-02-23
202035247850 Annual Report 2020-02-26
201985876130 Annual Report 2019-02-04
201858867810 Annual Report 2018-02-23
201734469060 Annual Report 2017-02-21
201692679220 Annual Report 2016-02-18
201555106230 Annual Report 2015-02-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347592412 0112300 2024-06-18 200 1ST AVENUE, CRANSTON, RI, 02910
Inspection Type Unprog Rel
Scope Partial
Safety/Health Health
Close Conference 2024-06-18
Emphasis L: R1Noise, N: DUSTEXPL
Case Closed 2025-02-04

Related Activity

Type Inspection
Activity Nr 1741431
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2024-12-11
Abatement Due Date 2025-01-13
Current Penalty 2212.2
Initial Penalty 3687.0
Final Order 2025-01-06
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line Section 5(a)(l) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm, including severe burns, to employees in that employees were exposed to fire, flash fire, deflagration, or explosion hazards from an improperly maintained dust collection system and duct work for combustible metal materials located inside a building : (a) In the Polishing Area - On or about June 18, 2024: (1) Accumulations of metal dusts were not removed promptly from horizontal surfaces adjacent to the dust collection systems including electrical conduit and boxes on walls and equipment. (2) The dust collection system's nonmetallic dust collection duct work was not properly grounded.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100305 G01 IV A
Issuance Date 2024-12-11
Abatement Due Date 2025-01-13
Current Penalty 2212.2
Initial Penalty 3687.0
Final Order 2025-01-06
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) In the Polishing Area: On or about June 18, 2024, the employer was relying on electrical extension cords run through building walls to power strips to provide electricity to cell phone chargers and refrigerators.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100307 C
Issuance Date 2024-12-11
Abatement Due Date 2025-01-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2025-01-06
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: (a) In the Polishing Area: On or about June 18, 2024, where aluminum parts are buffed and polished on powered equipment, electrical outlet boxes, switches, refrigerators, extension cords and power strips were not rated as intrinsically safe, approved for a Class II, Division II location, or safe for a Class II, Division II location.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100094 B05 V
Issuance Date 2024-12-11
Abatement Due Date 2025-01-13
Current Penalty 2212.2
Initial Penalty 3687.0
Final Order 2025-01-06
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.94(b)(5)(v): Hoods for polishing and buffing and scratch-brush wheels were not constructed to conform as closely to figure G-4 as the nature of the work will permit. (a) In the Polishing Area: On or about June 18, 2024, the hood on the left-hand side pedestal polishing unit did not completely enclose the sides of the polishing wheel, exposing employees to the rotating shaft of the polishing unit.
347414310 0112300 2024-04-16 200 1ST AVENUE, CRANSTON, RI, 02910
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2024-04-16
Emphasis L: R1Noise

Related Activity

Type Complaint
Activity Nr 2149112
Health Yes
Type Inspection
Activity Nr 1759241
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100095 D01
Issuance Date 2024-10-07
Abatement Due Date 2025-01-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-11-04
Nr Instances 1
Nr Exposed 15
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(d)(1): When information indicated that any employee's exposure to noise equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: (a) Facility-wide: On or about April 16, 2024, the employer did not develop and implement a noise monitoring program.
Citation ID 01002
Citaton Type Other
Standard Cited 19100134 D01 III
Issuance Date 2024-10-07
Abatement Due Date 2024-12-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-11-04
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (a) Throughout the Establishment: On or about April 16, 2024, the employer did not identify and evaluate the respiratory hazard(s) in the workplace, including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form for employee exposure to respirable metals, which is contained in the Stainless Steel and Aluminum products when polishing finished goods.
347252033 0112300 2024-02-02 200 1ST AVENUE, CRANSTON, RI, 02910
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2024-02-02
Emphasis N: AMPUTATE

Related Activity

Type Complaint
Activity Nr 2124237
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2024-07-23
Abatement Due Date 2024-08-09
Current Penalty 3226.0
Initial Penalty 6452.0
Final Order 2024-08-19
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Production Floor: On or about 2/2/24, the employer did not ensure that the Rotomat was properly guarded. The light curtains that were mounted around the parameter of the Rotomat were inoperable and the electrical connections were not connected. b) Production Floor: On or about 2/2/24, the employer did not ensure that the Brother TC-32A, CNC Tapping Center, SER. No. 111138, was properly guarded. The door safety interlocks were bypassed. c) Production Floor: On or about 2/2/24, the employer did not ensure that the Brother TC-32A, CNC Tapping Center, SER. No. 111222, was properly guarded. The door safety interlocks were bypassed. d) Production Floor: On or about 2/2/24, the employer did not ensure that the Kitamura MYCENTER 4XV, SERIAL NO. 39344, was properly guarded. The door safety interlocks were bypassed.
343913083 0112300 2019-04-05 112 DILLABUR AVENUE, NORTH KINGSTOWN, RI, 02852
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2019-04-05
Emphasis L: FORKLIFT, N: AMPUTATE
Case Closed 2020-06-26

Related Activity

Type Complaint
Activity Nr 1442249
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100132 D01
Issuance Date 2019-04-22
Abatement Due Date 2019-06-06
Current Penalty 2082.0
Initial Penalty 3031.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): (a) Worksite On or about 4/5/2019, the employer did not ensure that a hazard assessment for personal protective equipment (PPE) was completed and certified, and that the necessary PPE was selected and provided to employees for tasks such as cleaning out machines and handling metal chips.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100147 C04 II
Issuance Date 2019-04-22
Abatement Due Date 2019-06-28
Current Penalty 2612.0
Initial Penalty 3789.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section. (a) Worksite On or about 4/5/2019, the employer did not ensure that the energy control procedures addressed machine specific energy sources and techniques required during the Lockout/Tag-out process.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100147 C07 I A
Issuance Date 2019-04-22
Abatement Due Date 2019-06-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. (a) Worksite On or about 4/5/2019, the employer did not ensure that employees authorized to perform Lockout/Tag-out were trained in the application of the energy control procedure.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100147 C07 I B
Issuance Date 2019-04-22
Abatement Due Date 2019-06-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: (a) Worksite On or about 4/5/2019, the employer did not ensure that machine operators and tool room personnel who are affected by Lockout/Tag-out were trained in the energy control procedure.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100178 L04 III
Issuance Date 2019-04-22
Abatement Due Date 2019-06-06
Current Penalty 2612.0
Initial Penalty 3789.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: (a) Worksite On or about 4/5/2019, the employer did not ensure that each forklift operator underwent a skills evaluation at least once every three years.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2019-04-22
Abatement Due Date 2019-06-28
Current Penalty 2612.0
Initial Penalty 3789.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. (a) Worksite On or about 4/5/2019, the employer did not ensure that machine guarding was provided on the following machines: Vertical Milling Machines, Lathe, Snow Drills, Bending Machines, Belt Sander and Bench Grinder.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100212 B
Issuance Date 2019-04-22
Abatement Due Date 2019-06-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-09
Nr Instances 3
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machines designed for fixed locations were not securely anchored to prevent walking or moving: (a) Worksite On or about 4/5/2019, the employer did not ensure that floor and bench mounted pedestal drill presses were secured from movement.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 2019-04-22
Abatement Due Date 2019-06-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: (a) Worksite On or about 4/5/2019, the employer did not ensure that a bench grinder was being used with work rests adjusted to within one eight inch, to support offhand grinding.
Citation ID 01004D
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2019-04-22
Abatement Due Date 2019-06-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Worksite On or about 4/5/2019, the employer did not ensure that the bench grinder was equipped with tongue guards that were adjusted to within one fourth inch from the abrasive wheel.
Citation ID 01005
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2019-04-22
Abatement Due Date 2019-06-06
Current Penalty 2082.0
Initial Penalty 3031.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Worksite On or about 4/5/2019, the employer did not ensure that all employees working with chemical products underwent hazard communication training when they initially began their assignment with the company, or at any time after that.
Citation ID 02001
Citaton Type Other
Standard Cited 19100178 A04
Issuance Date 2019-04-22
Abatement Due Date 2019-06-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of a powered industrial truck were performed by the employer without the manufacturer's prior written approval. (a) Worksite On or about 4/5/2019, the employer did not ensure that the forklift data plate reflected the rated capacity change from using a boom attachment for offloading metal stock from box trucks.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
6303307006 2020-04-06 0165 PPP 200 1st Ave, CRANSTON, RI, 02910-5029
Loan Status Date 2021-01-14
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 241000
Loan Approval Amount (current) 241000
Undisbursed Amount 0
Franchise Name -
Lender Location ID 120245
Servicing Lender Name Bank Rhode Island
Servicing Lender Address One Turks Head Place, PROVIDENCE, RI, 02903-2219
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address CRANSTON, PROVIDENCE, RI, 02910-5029
Project Congressional District RI-02
Number of Employees 23
NAICS code 339999
Borrower Race White
Borrower Ethnicity Not Hispanic or Latino
Business Type Subchapter S Corporation
Originating Lender ID 120245
Originating Lender Name Bank Rhode Island
Originating Lender Address PROVIDENCE, RI
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 242626.75
Forgiveness Paid Date 2020-12-21

U.S. Small Business Administration Profile

Status User ID Name of Firm Trade Name UEI Address
Active P2194982 VEMALINE PRODUCTS INC HANDLES UNLIMITED XLW5JS7LHFK8 200 1ST AVE, CRANSTON, RI, 02910-5029
Capabilities Statement Link -
Phone Number 401-667-7870
Fax Number -
E-mail Address jeff@handlesunlimited.com
WWW Page www.handlesunlimited.com
E-Commerce Website http://www.handlesunlimited.com
Contact Person JEFFREY PANEK
County Code (3 digit) 007
Congressional District 02
Metropolitan Statistical Area 6480
CAGE Code 08730
Year Established 2010
Accepts Government Credit Card Yes
Legal Structure Subchapter S Corporation
Ownership and Self-Certifications Self-Certified Small Disadvantaged Business
Business Development Servicing Office RHODE ISLAND DISTRICT OFFICE (SBA office code 0165)
Capabilities Narrative In business for over 60 years, Handles Unlimited is an ISO 9001 compliant manufacturer of standard and custom handles, pulls and knobs for use in the commercial, military, electronics, medical and food service industries. Our handles and knobs are manufactured in the USA with durable materials including aluminum, brass and DFARS compliant stainless steel with a variety of finishes. We specialize in engineered solutions for custom designs, with metric equivalents and mil spec/RoHs compliance, while keeping many standard products in stock.
Special Equipment/Materials custom bending and forming equipment. CNC Swiss Screw Machines. Vertical CNC with pallet change. Hard alloys including A286ss and 17-4ph ss
Business Type Percentages Manufacturing (100 %)
Keywords manufacturer of standard and custom handles, pulls and knobs for use in the commercial, military, electronics, medical and food service industries
Quality Assurance Standards ISO-9000 Series
Electronic Data Interchange capable -

Current Principals

Name Jeffrey Panek
Role President

SBA Federal Certifications

HUBZone Certified No
Women Owned Certified No
Women Owned Pending No
Economically Disadvantaged Women Owned Certified No
Economically Disadvantaged Women Owned Pending No
Veteran-Owned Small Business Certified No
Veteran-Owned Small Business Joint Venture No
Service-Disabled Veteran-Owned Small Business Certified No
Service-Disabled Veteran-Owned Small Business Joint Venture No

Bonding Levels

Description Construction Bonding Level (per contract)
Level $0
Description Construction Bonding Level (aggregate)
Level $0
Description Service Bonding Level (per contract)
Level $0
Description Service Bonding Level (aggregate)
Level $0

NAICS Codes with Size Determinations by NAICS

Primary Yes
Code 332510
NAICS Code's Description Hardware Manufacturing
Buy Green Yes

Export Profile (Trade Mission Online)

Exporter Yes
Export Business Activities Manufacturer
Exporting to Brazil; Canada; Ireland; France; Germany; Hong Kong; Israel; Italy; Japan; Mexico; Netherlands; Singapore; Spain; Sweden; United Kingdom
Desired Export Business Relationships Direct export sales
Description of Export Objective(s) increase export sales

Date of last update: 14 Oct 2024