347993537
|
0112300
|
2025-01-23
|
500 HIGH STREET, CENTRAL FALLS, RI, 02863
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2025-01-23
|
Emphasis |
N: AMPUTATE, L: FORKLIFT, P: AMPUTATE
|
|
345522791
|
0112300
|
2021-09-10
|
500 HIGH STREET, CENTRAL FALLS, RI, 02863
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-09-10
|
Emphasis |
L: FORKLIFT, N: AMPUTATE
|
Case Closed |
2021-09-20
|
Related Activity
Type |
Complaint |
Activity Nr |
1806785 |
Safety |
Yes |
|
|
344064183
|
0112300
|
2019-06-07
|
500 HIGH STREET, CENTRAL FALLS, RI, 02863
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-06-07
|
Emphasis |
L: EISAOF, L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2019-10-07
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2019-06-18 |
Abatement Due Date |
2019-07-05 |
Current Penalty |
2536.0 |
Initial Penalty |
5072.0 |
Final Order |
2019-07-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) Worksite: On or about 6/7/2019, the employer did not ensure that a cut-off-saw positioned on a bench in the tool room was secured from movement. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19101200 F06 |
Issuance Date |
2019-06-18 |
Abatement Due Date |
2019-07-05 |
Current Penalty |
2027.0 |
Initial Penalty |
4057.0 |
Final Order |
2019-07-05 |
Nr Instances |
4 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section: (a) Worksite: On or about 6/7/2019, the employer did not ensure that each secondary container of lubricants and cleaning solutions was labeled to identify its contents, hazards and precautionary measures. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C06 I |
Issuance Date |
2019-06-18 |
Abatement Due Date |
2019-08-02 |
Current Penalty |
286.0 |
Initial Penalty |
569.0 |
Final Order |
2019-07-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Worksite: On or about 6/7/2019, the employer did not ensure that the energy control procedures were inspected annually, which would include an evaluation of the steps to be followed in each written procedure. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 I A |
Issuance Date |
2019-06-18 |
Abatement Due Date |
2019-08-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-07-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: (a) Worksite - Maintenance Department: On or about 6/7/2019, the employer did not maintain a three foot space in front of a live circuit breaker box. |
|
|
343471488
|
0112300
|
2018-09-19
|
500 HIGH STREET, CENTRAL FALLS, RI, 02863
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-09-19
|
Case Closed |
2018-11-29
|
Related Activity
Type |
Referral |
Activity Nr |
1382527 |
Safety |
Yes |
|
|
338951452
|
0112300
|
2013-03-12
|
175 DUPONT DRIVE, PROVIDENCE, RI, 02907
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-09-06
|
Emphasis |
L: EISAOF, L: FORKLIFT, N: AMPUTATE
|
Case Closed |
2013-12-02
|
Related Activity
Type |
Referral |
Activity Nr |
808500 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
782242 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
895124 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100036 D |
Issuance Date |
2013-09-09 |
Abatement Due Date |
2013-10-01 |
Current Penalty |
0.0 |
Initial Penalty |
3570.0 |
Final Order |
2013-09-20 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(d): Exit doors were locked: a) Adjacent to the Gun Barrel Manufacturing Department: During the second and third shifts, the second exit route was locked for security purposes leaving employees working with only one exit route. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100178 Q07 |
Issuance Date |
2013-09-09 |
Abatement Due Date |
2013-10-01 |
Current Penalty |
1487.5 |
Initial Penalty |
2975.0 |
Final Order |
2013-09-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(q)(7): Industrial trucks were not examined, at least daily or before each shift if used on a round-the clock basis, before being placed into service: a) Throughout the Establishment: The TCM FCG25 powered industrial truck used by employees working on two shifts, was not inspected daily, and at the the start of each shift, before being placed in service. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100332 B03 |
Issuance Date |
2013-09-09 |
Abatement Due Date |
2013-10-01 |
Current Penalty |
1487.5 |
Initial Penalty |
2975.0 |
Final Order |
2013-09-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.332(b)(3): Employees were not trained in and familiar with the safety related work practices required by 29 CFR 1910.331 through 29 CFR 1910.335 that pertained to their respective job assignments: a) Throughout the Establishment: Employees were performing electrical testing with equipment such as, but not limited to, Fluke meter and volt meter when ensuring absence of voltage, and had not been trained in safety related work practices of this standard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C06 I |
Issuance Date |
2013-09-09 |
Abatement Due Date |
2013-10-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-09-20 |
Nr Instances |
1 |
Nr Exposed |
20 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Throughout the Establishment: At the time of the inspection, the employer had not conducted a periodic inspection at least annually of the energy control procedures to ensure that they were being followed. |
|
|
337822423
|
0112300
|
2012-12-13
|
175 DUPONT DR, PROVIDENCE, RI, 02907
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2013-05-07
|
Case Closed |
2014-04-01
|
Related Activity
Type |
Inspection |
Activity Nr |
895881 |
Health |
Yes |
|
Type |
Complaint |
Activity Nr |
699471 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
895145 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 D01 |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-07-30 |
Current Penalty |
1190.0 |
Initial Penalty |
2380.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(d)(1): Flights of stairs having four or more risers were not equipped with a standard railing as specified in paragraphs (d)(1)(i) through (v) of this section: Workplace: On or about December 13, 2012 the exterior stairs for the north side exit on the loading dock had five risers and was not provided with standard stair railings. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100038 B |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-08-29 |
Current Penalty |
1190.0 |
Initial Penalty |
2380.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
38 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review: Workplace: On or about December 19, 2012 the employer had not established a written emergency action plan. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100132 D02 |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-07-30 |
Current Penalty |
1785.0 |
Initial Penalty |
3570.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
38 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2): Workplace: On or about December 19, 2012 the employer had not certified that the required workplace hazard assessment had been performed. Employees are exposed to foot, hand, arm, upper body and face hazards from corrosive chemicals , heavy objects, sharp edges and metal fragments . Abatement Note: Once the PPE Hazard Assessment is completed you shall: 1) Certify that the hazard assessment has been performed through a written certification in accordance with 1910.132 (d) (2), 2) Provide training to affected employees in proper use of required PPE (1910.132 (f) (1)), and 3) Verify that the training of each affected employee has been completed and documented through a written certification in accordance with 1910.132 (d) (4). Guidance on conducting and documenting a PPE Hazard Assessment can be found on OSHA's website at: http://www.osha.gov/SLTC/personalprotectiveequipment |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100132 F01 |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-07-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
38 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment: Workplace: On or about December 19, 2012 the employer had not ensured that employees were trained in proper use of PPE. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-06-07 |
Current Penalty |
1487.0 |
Initial Penalty |
2975.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: Workplace: On or about December 13, 2012 the employer had not ensured that employees using corrosive chemicals, including Flexiclean, were provided with adequate eye and facial protection. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-07-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Workplace: On or about December 13, 2012 the employer had not ensured that employees using corrosive chemicals including Flexiclean were provided with suitable facilities for the flushing of the eyes. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100303 G01 |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-05-30 |
Current Penalty |
1190.0 |
Initial Penalty |
2380.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
38 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Workplace: On or about December 13, 2012 the employer had not ensured that the electrical switching panels on the north and south walls of the Rosco production area had sufficient access and working space provided. |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 I |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-08-26 |
Current Penalty |
2450.0 |
Initial Penalty |
4900.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
38 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet: Workplace: On or about December 19, 2012 the employer's Hazard Communication Program did not include a listing of the hazardous chemicals used in this workplace. |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19101200 F05 II |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-06-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
38 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: Workplace: On or about December 13, 2012 the employer did not ensure that containers of hazardous materials, including spray bottles of Stone Cleaner and a bucket of diluted Flexiclean, were labeled with appropriate hazard warnings. |
|
Citation ID |
01006C |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-07-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
38 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: Workplace: On or about December 19, 2012 the employer did not maintain copies of the material safety data sheets in an area accessible to employees on the second and third shifts. MSDS were maintained in the Safety and Health Manager's Office. |
|
Citation ID |
01006D |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-07-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
38 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Workplace: On or about December 19, 2012 the employer had not trained employees when they were initially hired on the hazardous chemicals that they use in their workplaces. Employees work with several hazardous chemicals including Castrol's Flexiclean and Rustilio DWX 30. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100037 A03 |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-06-07 |
Current Penalty |
298.0 |
Initial Penalty |
595.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
38 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: Workplace: On or about December 19, 2012 the emergency exit door landing on the north side of the loading dock area was partially obstructed by a parked truck. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100095 D01 |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-08-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
38 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: Workplace: On or about December 13, 2012 the employer had implemented a hearing conservation program based on incomplete test data in that the monitoring was less than 3 hours. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100134 D01 III |
Issuance Date |
2013-05-30 |
Abatement Due Date |
2013-08-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
15 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: Workplace: On or about December 13, 2012 the employer had not conducted air quality monitoring in the production area to determine if employees were exposed to respiratory hazards. Employees regularly work with metal working fluids and corrosion inhibitors. |
|
|