343575171
|
0112300
|
2018-11-01
|
1466 BROAD STREET, PROVIDENCE, RI, 02905
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-11-01
|
Emphasis |
L: FALL
|
Case Closed |
2018-12-12
|
Related Activity
Type |
Complaint |
Activity Nr |
1396968 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2018-11-13 |
Current Penalty |
0.0 |
Initial Penalty |
5691.0 |
Final Order |
2018-11-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) Worksite On or about 11/1/2018, an employee was not protected from overhead hazards while working below roofers. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260252 A |
Issuance Date |
2018-11-13 |
Abatement Due Date |
2018-11-16 |
Current Penalty |
0.0 |
Initial Penalty |
5691.0 |
Final Order |
2018-11-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s): (a) Worksite On or about 11/1/2018, an enclosed chute was not used where materials were dropped approximately 21.7 feet outside the building. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260502 H01 V |
Issuance Date |
2018-11-13 |
Current Penalty |
0.0 |
Initial Penalty |
5691.0 |
Final Order |
2018-11-20 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(h)(1)(v): The safety monitor had other responsibilities which could take the monitor's attention from the monitoring function: (a) Worksite On or about 11/1/2018, the safety monitor was observed throwing materials off the roof into a dumpster below with his back towards employees he was supposed to be monitoring that were working along the edge of the roof approximately 21.7 feet above the lower level. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260502 H02 |
Issuance Date |
2018-11-13 |
Abatement Due Date |
2018-11-16 |
Current Penalty |
2844.0 |
Initial Penalty |
0.0 |
Final Order |
2018-11-20 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(h)(2): Mechanical equipment was used and stored in an area where a safety monitoring system was used to protect employees who were involved in roofing operations: (a) Worksite On or about 11/1/2018, the employer used a safety monitor system as the means for fall protection on a roof surface approximately 21.7 feet above the lower level where mechanical roof strippers were used and stored. |
|
|
342329521
|
0112300
|
2017-05-16
|
26 SHIP STREET, PROVIDENCE, RI, 02903
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-05-16
|
Emphasis |
L: EISAOF, L: FALL
|
Case Closed |
2017-08-07
|
Related Activity
Type |
Complaint |
Activity Nr |
1214816 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1232985 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2017-05-30 |
Current Penalty |
1600.0 |
Initial Penalty |
3386.0 |
Final Order |
2017-08-07 |
Nr Instances |
1 |
Nr Exposed |
9 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Worksite - Roof hatch: On or about 5/16/2017, employees were not protected from falling while using a ladder that did not extend at least three feet above the upper landing surface. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261053 B16 |
Issuance Date |
2017-05-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-08-07 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: (a) Worksite: On or about 5/16/2017, a portable ladder that was damaged was not withdrawn from service. |
|
|
340591320
|
0112300
|
2015-04-28
|
2232 MIDDLE ROAD, PORTSMOUTH, RI, 02871
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-04-28
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2019-01-25
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2015-08-04 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-08-27 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Worksite: Employees were not using fall protection while exposed to fall hazards of more than 6 feet. |
|
|
339913568
|
0112300
|
2014-08-20
|
677 BOSTON NECK ROAD, NARRAGANSETT, RI, 02879
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-08-20
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2016-06-23
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2015-01-15 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-02-20 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure: Worksite: The employer did not ensure the use of personal fall protection when employees were performing roofing activities, and were exposed to falls in excess of 6 feet above ground level. |
|
|