342748969
|
0112300
|
2017-11-02
|
801 GREENWICH AVE., WARWICK, RI, 02886
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-11-03
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-01-11
|
Related Activity
Type |
Complaint |
Activity Nr |
1280769 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2017-11-21 |
Current Penalty |
2000.0 |
Initial Penalty |
3803.0 |
Final Order |
2017-12-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: (a) Roof of the Crown Plaza Hotel: On or about 11/2/2017, employees engaged in activities on a low-slope roof with unprotected sides and edges 6 feet or more above the lower level were not protected by a guardrail system, safety net system, personal fall arrest system or a safety monitoring system. |
|
|
341123610
|
0112300
|
2015-12-16
|
1414 ATWOOD AVENUE, JOHNSTON, RI, 02919
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-12-16
|
Emphasis |
L: EISAOF, L: FALL
|
Case Closed |
2016-02-03
|
Related Activity
Type |
Complaint |
Activity Nr |
1046535 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19260502 F01 I |
Issuance Date |
2015-12-18 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2016-01-07 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(f)(1)(i): When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roofs edge: (a) Worksite - Roof: On or about 12/16/2015, employees were exposed to fall hazards while working on a flat commercial roof 26 to 41 feet above the lower level, where the stanchions and warning lines were set up approximately four feet from the roof's edge. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19260502 F02 II |
Issuance Date |
2015-12-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-01-07 |
Nr Instances |
3 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface: (a) Worksite - Roof: On or about 12/16/2015, employees were exposed to fall hazards while working on a flat commercial roof 26 to 41 feet above the lower level, where the warning lines sagged below 34 inches in height from the roof's surface. |
|
|