339657777
|
0112300
|
2014-03-21
|
45 READ AVENUE, COVENTRY, RI, 02816
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-03-21
|
Emphasis |
L: RESCON, L: FALL
|
Case Closed |
2014-10-16
|
Related Activity
Type |
Complaint |
Activity Nr |
877501 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-07-17 |
Current Penalty |
3000.0 |
Initial Penalty |
6160.0 |
Final Order |
2014-08-18 |
Nr Instances |
2 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: Jobsite: On, or about, 03/21/2014 Employees were performing construction activities on the roof of residential structures and were not protected by a guardrail system, net system, or personal fall protection in the following instances: House structure: Two employees were applying asphalt shingles to the porch roof and were exposed to a fall of approximately 10 feet. Shed: An employee was applying asphalt shingles to the porch roof and was exposed to a fall of approximately nine feet. The DePietro Roofing, Inc.was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13) which was contained in OSHA inspection number 312346299, citation number 1, item number 2 and was affirmed as a final order on 07/08/2010, with respect to a workplace located at 657 Knotty Oak Road, Coventry, RI. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2014-07-17 |
Current Penalty |
1000.0 |
Initial Penalty |
4400.0 |
Final Order |
2014-08-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: Jobsite, Porch roof structure: Employees were using the Louisville portable extension ladder to access the porch roof whereby the ladder side rails did not extend a minimum of three (3) feet above the upper landing surface. The DePietro Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926. 1053(b)(1), which was contained in OSHA inspection number 312342041, citation number 1, item number 3 and was affirmed as a final order on 06/10/2009, with respect to a workplace located at 672 Washington Street, Coventry, RI. |
|
|
314916255
|
0112300
|
2011-02-17
|
767 TIOGUE AVE., COVENTRY, RI, 02816
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-02-17
|
Emphasis |
S: RESIDENTIAL CONSTR, L: FALL, S: FALL FROM HEIGHT
|
Case Closed |
2011-03-02
|
Related Activity
Type |
Complaint |
Activity Nr |
208124404 |
Safety |
Yes |
|
|
312346299
|
0112300
|
2010-06-11
|
657 KNOTTY OAK RD, COVENTRY, RI, 02816
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-06-11
|
Emphasis |
L: FALL, S: ELECTRICAL, S: RESIDENTIAL CONSTR, L: RESCON, S: FALL FROM HEIGHT
|
Case Closed |
2010-07-19
|
Related Activity
Type |
Complaint |
Activity Nr |
207641630 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260416 A01 |
Issuance Date |
2010-06-24 |
Abatement Due Date |
2010-06-29 |
Current Penalty |
500.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2010-06-24 |
Abatement Due Date |
2010-06-30 |
Current Penalty |
1400.0 |
Initial Penalty |
2800.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2010-06-24 |
Abatement Due Date |
2010-07-20 |
Current Penalty |
500.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
|
312342041
|
0112300
|
2009-06-02
|
672 WASHINGTON STREET, COVENTRY, RI, 02816
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2009-06-02
|
Emphasis |
L: RESCON, L: EISA, L: FALL
|
Case Closed |
2009-07-06
|
Related Activity
Type |
Complaint |
Activity Nr |
207158163 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2009-06-05 |
Abatement Due Date |
2009-06-10 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2009-06-05 |
Abatement Due Date |
2009-06-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260252 A |
Issuance Date |
2009-06-05 |
Abatement Due Date |
2009-06-10 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2009-06-05 |
Abatement Due Date |
2009-06-10 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
03 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040001 A01 |
Issuance Date |
2009-06-05 |
Abatement Due Date |
2009-08-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
00 |
|
|