Name: | JDI Construction, Inc. |
Jurisdiction: | Rhode Island |
Entity type: | Domestic Profit Corporation |
Status: | Activ |
Date of Organization in Rhode Island: | 17 Dec 2003 (21 years ago) |
Identification Number: | 000136604 |
ZIP code: | 02865 |
County: | Providence County |
Principal Address: | 32 HARRIS AVE, LINCOLN, RI, 02865, USA |
Purpose: | TO PROVIDE MASONRY, CONSTRUCTION, PLOWING AND MAINTENANCE SERVICES TO THE RESIDENTIAL, COMMERCIAL, INDUSTRIAL AND PUBLIC SECTIONS. |
NAICS
238140 Masonry ContractorsThis industry comprises establishments primarily engaged in masonry work, stone setting, bricklaying, and other stone work. The work performed may include new work, additions, alterations, maintenance, and repairs. Learn more at the U.S. Census Bureau
Name | Role | Address |
---|---|---|
JON D. ISRAEL | Agent | 32 HARRIS AVENUE, LINCOLN, RI, 02865, USA |
Name | Role | Address |
---|---|---|
JON D ISRAEL | PRESIDENT | 32 HARRIS AVE LINCOLN, RI 02865 USA |
Name | Role | Address |
---|---|---|
JON ISRAEL | OTHER OFFICER | 32 HARRIS AVE LINCOLN, RI 02865 UNI |
Number | Name | File Date |
---|---|---|
202448642060 | Annual Report | 2024-03-15 |
202329102290 | Annual Report | 2023-02-22 |
202212247370 | Annual Report | 2022-03-06 |
202192495020 | Annual Report | 2021-02-22 |
202190415750 | Statement of Change of Registered/Resident Agent | 2021-02-08 |
202189929990 | Revocation Notice For Failure to Maintain a Registered Office | 2021-02-04 |
202189360540 | Registered Office Not Maintained | 2021-01-15 |
202032155130 | Annual Report | 2020-01-13 |
201988172860 | Annual Report | 2019-03-05 |
201755076450 | Annual Report | 2017-12-14 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
335240982 | 0112300 | 2012-08-06 | 33 STIMSON AVENUE, PROVIDENCE, RI, 02906 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 441710 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 A01 |
Issuance Date | 2012-10-02 |
Abatement Due Date | 2012-10-07 |
Current Penalty | 250.0 |
Initial Penalty | 2800.0 |
Final Order | 2012-10-30 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(a)(1): Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it: a. Jobsite: On or about July, 11, 2012, an employee was injured when the chimney roof bracket failed to support at least 4 times the maximum intended load. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260451 C01 |
Issuance Date | 2012-10-02 |
Abatement Due Date | 2012-10-07 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-10-30 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph: a. Jobsite: The scaffold was not restrained from tipping by guying, tying, bracing or equivalent means. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2012-10-02 |
Abatement Due Date | 2012-10-07 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-10-30 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Variance |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a. Jobsite: Employees were not provided with ladders or equivalent when accessing the scaffold. |
Citation ID | 01001D |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2012-10-02 |
Abatement Due Date | 2012-10-07 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-10-30 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. Jobsite: On or about July 11, 2012, an employee working from the chimney roof bracket fell to the ground. The employee was not provided with adequate fall protection. |
Citation ID | 01001E |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2012-10-02 |
Abatement Due Date | 2012-10-07 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-10-30 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a. Jobsite: The employer did not have a qualified person train each employee to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2008-11-13 |
Emphasis | S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT, L: FALL, L: EISA |
Case Closed | 2013-12-06 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260416 A01 |
Issuance Date | 2008-11-20 |
Abatement Due Date | 2008-11-25 |
Current Penalty | 750.0 |
Initial Penalty | 1500.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
Citation ID | 01002A |
Citaton Type | Other |
Standard Cited | 19260453 B02 IV |
Issuance Date | 2008-11-20 |
Abatement Due Date | 2008-11-25 |
Initial Penalty | 750.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 03 |
Citation ID | 01002B |
Citaton Type | Other |
Standard Cited | 19260453 B02 V |
Issuance Date | 2008-11-20 |
Abatement Due Date | 2008-11-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 03 |
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2506734 | Interstate | 2025-02-06 | 10000 | 2024 | 1 | 1 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 0 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 0 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 0 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Date of last update: 11 Apr 2025
Sources: Rhode Island Department of State