Search icon

DCS CONSTRUCTION, LLC

Company Details

Name: DCS CONSTRUCTION, LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Dissolved
Date of Organization in Rhode Island: 30 Jan 2004 (21 years ago)
Date of Dissolution: 03 Aug 2021 (4 years ago)
Date of Status Change: 03 Aug 2021 (4 years ago)
Identification Number: 000137677
ZIP code: 02838
County: Providence County
Principal Address: 315 OLD RIVER ROAD UNIT 8, MANVILLE, RI, 02838, USA
Purpose: CONCRETE STONE MASONARY

Industry & Business Activity

NAICS

238140 Masonry Contractors

This industry comprises establishments primarily engaged in masonry work, stone setting, bricklaying, and other stone work. The work performed may include new work, additions, alterations, maintenance, and repairs. Learn more at the U.S. Census Bureau

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
D C S CONSTRUCTION L L C 401(K) PROFIT SHARING PLAN & TRUST 2009 200664371 2011-08-15 DCS CONSTRUCTION LLC No data
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2007-01-01
Business code 541990
Sponsor’s telephone number 4016921667
Plan sponsor’s mailing address PO BOX 337, WOONSOCKET, RI, 02895
Plan sponsor’s address PO BOX 337, WOONSOCKET, RI, 02895

Plan administrator’s name and address

Administrator’s EIN 200664371
Plan administrator’s name DCS CONSTRUCTION LLC
Plan administrator’s address PO BOX 337, WOONSOCKET, RI, 02895
Administrator’s telephone number 4016921667

Agent

Name Role Address
LESZEK PRZYBYLKO Agent 315 OLD RIVER ROAD UNIT 8, MANVILLE, RI, 02838, USA

Manager

Name Role Address
LESSEX PRZYBYLKO Manager 315 OLD RIVER ROAD MANVILLE, RI 02838 USA

Filings

Number Name File Date
202199865150 Articles of Dissolution 2021-08-03
202195626340 Annual Report 2021-04-09
202194440820 Revocation Notice For Failure to File An Annual Report 2021-03-16
201918740510 Annual Report 2019-09-06
201881845230 Annual Report 2018-11-28
201872309680 Statement of Change of Registered/Resident Agent Office 2018-07-12
201866490080 Annual Report 2018-05-21
201866490170 Statement of Change of Registered/Resident Agent Office 2018-05-21
201865602790 Revocation Notice For Failure to File An Annual Report 2018-05-15
201608482010 Annual Report 2016-09-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341200251 0112300 2016-01-25 369 PARK EAST DRIVE, WOONSOCKET, RI, 02895
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2016-01-25
Emphasis L: FALL
Case Closed 2017-04-12

Related Activity

Type Inspection
Activity Nr 1120078
Safety Yes
Type Complaint
Activity Nr 1056566
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2016-02-18
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2016-03-22
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) Worksite: On or about 1/25/2016, employees were not protected from overhead hazards while working in close proximity to masons laying concrete block from a scaffold system.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2016-02-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-22
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: (a) Worksite: On or about 1/25/2016, eye and face protective equipment was not used when employees worked with cement and hand power tools, such as a drill, rotary hammer and a circular saw.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260416 E01
Issuance Date 2016-02-18
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2016-03-22
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) Worksite: On or about 1/25/2016, employees were not protected from electric shock and burns from an electrical cord that was worn and frayed.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2016-02-18
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-03-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a) Worksite: On or about 1/25/2016, an employee was not protected from falling while working from a scaffold platform that was not fully planked.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2016-02-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-22
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) Worksite: On or about 1/25/2016, employees were not protected from falling while working from a scaffold that was greater than 10 feet above a lower level.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2016-02-18
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2016-03-22
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladder was used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Worksite: On or about 1/25/2016, employees were not protected from falling while using a ladder that did not extend at least three feet above the upper landing surface.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2016-02-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-22
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder was used for purposes other than the purpose for which it was designed: (a) Worksite: On or about 1/25/2016, an extension ladder was separated into two single sections and used by employees to access a scaffold system.

Date of last update: 11 Apr 2025