Name: | South Beach Construction, Inc. |
Jurisdiction: | Rhode Island |
Entity type: | Domestic Profit Corporation |
Status: | Activ |
Date of Organization in Rhode Island: | 20 Jun 2000 (25 years ago) |
Identification Number: | 000113110 |
ZIP code: | 02903 |
County: | Providence County |
Principal Address: | 350 SOUTH MAIN STREET, PROVIDENCE, RI, 02903, USA |
Purpose: | CONSTRUCTION SERVICES |
Historical names: |
SO BEACH CONSTRUCTION INC |
NAICS
236116 New Multifamily Housing Construction (except For-Sale Builders)This U.S. industry comprises general contractor establishments primarily responsible for the construction of new multifamily residential housing units (e.g., high-rise, garden, town house apartments, and condominiums where each unit is not separated from its neighbors by a ground-to-roof wall). Multifamily design-build firms and multifamily housing construction management firms acting as general contractors are included in this industry. Learn more at the U.S. Census Bureau
Name | Role | Address |
---|---|---|
DAVID C. TAPALIAN, ESQ. | Agent | 350 SOUTH MAIN STREET, PROVIDENCE, RI, 02903, USA |
Name | Role | Address |
---|---|---|
HAIG CHARLES TAPALIAN | PRESIDENT | 44 DAVIS STREET SEEKONK, MA 02771 USA |
Name | Role | Address |
---|---|---|
DAVID TAPALIAN | OTHER OFFICER | 350 SOUTH MAIN STREET PROVIDENCE, RI 02903 UNI |
Type | Date | Old Value | New Value |
---|---|---|---|
Name Change | 2000-11-17 | SO BEACH CONSTRUCTION INC | South Beach Construction, Inc. |
Number | Name | File Date |
---|---|---|
202447510180 | Annual Report | 2024-02-29 |
202328462160 | Annual Report | 2023-02-15 |
202208417130 | Annual Report | 2022-01-21 |
202195954740 | Annual Report | 2021-04-26 |
202035893390 | Annual Report - Amended | 2020-03-05 |
202031116600 | Annual Report | 2020-01-06 |
201986337630 | Annual Report | 2019-02-11 |
201857662920 | Statement of Change of Registered/Resident Agent Office | 2018-02-06 |
201857062720 | Annual Report | 2018-01-30 |
201857060690 | Statement of Change of Registered/Resident Agent Office | 2018-01-30 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345001234 | 0112300 | 2020-10-27 | 700 GREENVILLE AVE BOULDER FARM VILLAS, JOHNSTON, RI, 02919 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1755086 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1500097 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2021-04-21 |
Current Penalty | 3901.0 |
Initial Penalty | 3901.0 |
Final Order | 2021-05-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) Trench on jobsite On or about 10/27/20, an employee was not protected from overhead danger by way of a protective helmet, while working along the base of a trench over five feet in depth. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260651 J02 |
Issuance Date | 2021-04-21 |
Current Penalty | 5461.0 |
Initial Penalty | 5461.0 |
Final Order | 2021-05-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. (a) Trench on jobsite On or about 10/27/20, protection was not provided to prevent materials or equipment from falling or rolling into excavations by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2021-04-21 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-05-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). (a) Jobsite On or about 10/27/20, an employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2021-04-21 |
Current Penalty | 5461.0 |
Initial Penalty | 5461.0 |
Final Order | 2021-05-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access and the ladder was not secured at its top to a rigid support: (a) Jobsite On or about 10/27/20, the ladder side rails on a stepladder did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access to and from the base of the trench. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2021-04-21 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-05-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) Jobsite On or about 10/27/20, an employee utilized a stepladder as a means of access to and from a trench while in the folded closed position. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8476347004 | 2020-04-08 | 0165 | PPP | P.O. BOX 6684, PROVIDENCE, RI, 02940 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|