Name: | B.E. LOPEZ CONSTRUCTION LLC |
Jurisdiction: | Rhode Island |
Entity type: | Domestic Limited Liability Company |
Status: | Revoked Entity |
Date of Organization in Rhode Island: | 10 Mar 2006 (19 years ago) |
Date of Dissolution: | 14 Feb 2022 (3 years ago) |
Date of Status Change: | 14 Feb 2022 (3 years ago) |
Identification Number: | 000154482 |
ZIP code: | 02920 |
County: | Providence County |
Principal Address: | 9 BAILEY STREET, CRANSTON, RI, 02920, USA |
Purpose: | CARPENTRY, REMODELING, VINYL SIDING AND RENOVATIONS |
NAICS
236116 New Multifamily Housing Construction (except For-Sale Builders)This U.S. industry comprises general contractor establishments primarily responsible for the construction of new multifamily residential housing units (e.g., high-rise, garden, town house apartments, and condominiums where each unit is not separated from its neighbors by a ground-to-roof wall). Multifamily design-build firms and multifamily housing construction management firms acting as general contractors are included in this industry. Learn more at the U.S. Census Bureau
Name | Role | Address |
---|---|---|
EDUARDO A. LOPEZ | Agent | 9 BAILEY STREET, CRANSTON, RI, 02920, USA |
Number | Name | File Date |
---|---|---|
202210228470 | Revocation Certificate For Failure to File the Annual Report for the Year | 2022-02-14 |
202106194980 | Revocation Notice For Failure to File An Annual Report | 2021-12-03 |
202050000940 | Annual Report | 2020-08-26 |
202050000670 | Annual Report | 2020-08-26 |
202045386510 | Revocation Notice For Failure to File An Annual Report | 2020-07-20 |
201993900780 | Annual Report | 2019-05-22 |
201992616600 | Revocation Notice For Failure to File An Annual Report | 2019-05-13 |
201753904070 | Annual Report | 2017-11-24 |
201611152070 | Annual Report | 2016-10-25 |
201587626980 | Annual Report | 2015-11-09 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340871524 | 0112300 | 2015-08-25 | 118 EUSTIS AVE., NEWPORT, RI, 02840 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2015-10-15 |
Current Penalty | 2100.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-11-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: Worksite: Working platform area was not fully planked for the width of the scaffold. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260451 G01 VII |
Issuance Date | 2015-10-15 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-11-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Worksite: Guardrails or fall protection was not provided for employees working from the scaffold. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 C02 II |
Issuance Date | 2015-10-15 |
Current Penalty | 0.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-11-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(c)(2)(ii): Unstable objects shall not be used to support scaffolds or platform units. Worksite: The fabricated framed scaffold being used had wheels set on unstable wood blocks. |
Inspection Type | Complaint |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2010-02-22 |
Emphasis | L: FALL, L: RESCON, S: FALL FROM HEIGHT, S: RESIDENTIAL CONSTR |
Case Closed | 2010-05-14 |
Related Activity
Type | Complaint |
Activity Nr | 207463522 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2010-05-11 |
Abatement Due Date | 2010-05-21 |
Current Penalty | 750.0 |
Initial Penalty | 1500.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2010-05-11 |
Abatement Due Date | 2010-05-21 |
Current Penalty | 400.0 |
Initial Penalty | 800.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 02 |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B07 |
Issuance Date | 2010-05-11 |
Abatement Due Date | 2010-05-21 |
Current Penalty | 400.0 |
Initial Penalty | 800.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 02 |
Date of last update: 10 Oct 2024