Search icon

KC & Son Unlimited LLC

Company Details

Name: KC & Son Unlimited LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Activ
Date of Organization in Rhode Island: 27 Oct 2022 (2 years ago)
Identification Number: 001747499
ZIP code: 02860
County: Providence County
Principal Address: 88 SENECA AVENUE, PAWTUCKET, RI, 02860, USA
Purpose: CONSTRUCTION CONTRACTOR

Agent

Name Role Address
KENNETH CORSI Agent 88 SENECA AVENUE, PAWTUCKET, RI, 02860, USA

Filings

Number Name File Date
202457629500 Annual Report 2024-07-05
202456247480 Revocation Notice For Failure to File An Annual Report 2024-06-18
202339714210 Annual Report 2023-07-24
202337099580 Revocation Notice For Failure to File An Annual Report 2023-06-16
202224189080 Articles of Organization 2022-10-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346822729 0112300 2023-07-11 63-65 WYNDHAM AVENUE, PROVIDENCE, RI, 02908
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2023-07-11
Emphasis N: FALL
Case Closed 2023-10-12

Related Activity

Type Complaint
Activity Nr 2052084
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 A01
Issuance Date 2023-09-19
Abatement Due Date 2023-11-03
Current Penalty 2812.8
Initial Penalty 4688.0
Final Order 2023-09-28
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(1): Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. (a) Worksite - Side of the building: On or about 07/11/2023, the employer allowed employees to utilize non-scaffold-grade planks as the walking/working surface of the scaffold.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2023-09-19
Abatement Due Date 2023-11-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-09-28
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation. (a) Worksite - Side of the building: On or about 07/11/2023, the employer allowed employees to assemble and use a pump jack scaffold system with 4 of the uprights resting on the ground, not bearing on base plates and mud sills, or another adequate firm foundation.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2023-09-19
Abatement Due Date 2023-11-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-09-28
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. (a)Worksite - Side of the building: On or about 07/11/2023, the employer allowed employees to assemble and use a pump jack scaffold system without supervision by a competent person qualified in scaffold erection in that the scaffold was missing a mid-rail, base plates, mud sills, and fall protection.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2023-09-19
Abatement Due Date 2023-11-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-09-28
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section. (a)Worksite - Side of the building: On or about 07/11/2023, the employer allowed employees to assemble and use a pump jack scaffold system, at a height of approximately 16 feet above the lower level, without any means of fall protection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260452 J02
Issuance Date 2023-09-19
Abatement Due Date 2023-11-03
Current Penalty 2812.8
Initial Penalty 4688.0
Final Order 2023-09-28
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. (a) Worksite - Side of the building: On or about 07/11/2023, the employer allowed employees to assemble and use a pump jack scaffold system with 4 upright poles not secured to the bottom of the structure by rigid triangular bracing or equivalent, thus exposing employees to scaffold collapse and fall hazards.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260452 J07
Issuance Date 2023-09-19
Abatement Due Date 2023-11-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-09-28
Nr Instances 2
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(j)(7): When two by fours are spliced to make a pole, mending plates shall be installed at all splices to develop the full strength of the member. (a) Worksite - Side of the building: On or about 07/11/2023, the employer allowed employees to assemble and use a pump jack scaffold system with 4 upright poles constructed from two-by-four lumber that was spliced together without mending plates installed at all splices, thus exposing employees to scaffold collapse and fall hazards.

Date of last update: 28 Oct 2024