Search icon

Specialty Roofing and Metal Work LLC

Company Details

Name: Specialty Roofing and Metal Work LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Revoked Entity
Date of Organization in Rhode Island: 30 Aug 2022 (3 years ago)
Date of Dissolution: 09 Oct 2024 (6 months ago)
Date of Status Change: 09 Oct 2024 (6 months ago)
Identification Number: 001745474
ZIP code: 02919
County: Providence County
Principal Address: 515 GREENVILLE AVENUE, JOHNSTON, RI, 02919, USA
Mailing Address: 206 UNIVERSITY AVE, PROVIDENCE, RI, 02919, USA
Purpose: METAL ROOFING, COPPER WORK, AND CUSTOM SHOP FABRICATION

Agent

Name Role Address
JESSE JAMES BRELOS Agent 6 EVERGREEN COURT, COVENTRY, RI, 02816, USA

Filings

Number Name File Date
202460534970 Revocation Certificate For Failure to File the Annual Report for the Year 2024-10-09
202458528370 Revocation Notice For Failure to File An Annual Report 2024-08-02
202458772340 Registered Office Not Maintained 2024-06-19
202456252880 Revocation Notice For Failure to File An Annual Report 2024-06-18
202339094790 Annual Report 2023-07-06
202337105920 Revocation Notice For Failure to File An Annual Report 2023-06-16
202222553540 Articles of Organization 2022-08-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346665110 0112300 2023-04-28 17 SYLVAN STREET, NEWPORT, RI, 02840
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2023-04-28
Emphasis P: FALL, L: FALL, N: CTARGET

Related Activity

Type Inspection
Activity Nr 1666529
Safety Yes
Type Inspection
Activity Nr 1666546
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2023-05-17
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-06-16
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift. Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated. a) Rear of the Carriage House: On or about 4/28/2023, an employee was permitted to perform work while utilizing an aerial lift without any means of fall protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-05-17
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-06-16
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection measure under another provision of paragraph 1926.501(b). a) Jobsite: On or about 4/28/2023, the employer did not ensure that an employee engaged in residential roofing activities, at heights of approximately 18 feet above the lower level, was protected from fall hazards.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2023-05-17
Abatement Due Date 2023-07-05
Current Penalty 376.0
Initial Penalty 376.0
Final Order 2023-06-16
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record. a) Jobsite: On or about 4/28/2023, the employer did not create a written certification record verifying that an employee received adequate fall protection training for employees exposed to fall hazards.
Citation ID 03001A
Citaton Type Other
Standard Cited 19030019 C01
Issuance Date 2023-08-24
Abatement Due Date 2023-09-27
Current Penalty 376.0
Initial Penalty 376.0
Final Order 2023-09-20
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: (a) Establishment: As of August 24, 2023, the employer had not certified to OSHA that the abatement had been completed for Citation 2, Item 1 from inspection number 1666511, issued on 5/17/2023, with a final order date of 6/16/2023.
Citation ID 03001B
Citaton Type Other
Standard Cited 19030019 D01
Issuance Date 2023-08-24
Abatement Due Date 2023-09-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-09-20
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(d)(1):The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: (a) Establishment: As of August 24, 2023, the employer had not provided the required abatement documentation to OSHA for Citation 2, Item 1 from inspection number 1666511 issued on 5/17/2023, with a final order date of 6/16/2023.

Date of last update: 28 Oct 2024

Sources: Rhode Island Department of State