Search icon

NDL Landscaping LLC

Company Details

Name: NDL Landscaping LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Revoked Entity
Date of Organization in Rhode Island: 14 Jan 2022 (3 years ago)
Date of Dissolution: 17 Sep 2024 (7 months ago)
Date of Status Change: 17 Sep 2024 (7 months ago)
Identification Number: 001734441
ZIP code: 02908
County: Providence County
Principal Address: 186 ADMIRAL STREET, PROVIDENCE, RI, 02908, USA
Purpose: LANDSCAPING

Industry & Business Activity

NAICS

561730 Landscaping Services

This industry comprises (1) establishments primarily engaged in providing landscape care and maintenance services and/or installing trees, shrubs, plants, lawns, or gardens and (2) establishments primarily engaged in providing these services along with the design of landscape plans and/or the construction (i.e., installation) of walkways, retaining walls, decks, fences, ponds, and similar structures. Learn more at the U.S. Census Bureau

Agent

Name Role Address
NEHEMIAS DE LEON Agent 186 ADMIRAL STREET, PROVIDENCE, RI, 02908, USA

Filings

Number Name File Date
202459823500 Revocation Certificate For Failure to File the Annual Report for the Year 2024-09-17
202456576120 Revocation Notice For Failure to File An Annual Report 2024-06-18
202339086560 Annual Report 2023-07-05
202337492570 Revocation Notice For Failure to File An Annual Report 2023-06-16
202207991550 Articles of Organization 2022-01-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347527269 0112300 2024-06-05 350 SMITH STREET, CRANSTON, RI, 02905
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-06-05
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2024-07-24
Current Penalty 1659.0
Initial Penalty 2765.0
Final Order 2024-08-23
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns. a) Jobsite: On or about 6/5/2024, two employees were not protected, by helmets, from flying or falling objects, while working below another employee standing on a residential roof.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-07-24
Current Penalty 1659.0
Initial Penalty 2765.0
Final Order 2024-08-23
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) Jobsite: On or about 6/5/2024, employees were not wearing protective eyewear while exposed to flying particles from stripping building materials off the side of a residential structure.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 A01
Issuance Date 2024-07-24
Current Penalty 2903.4
Initial Penalty 4839.0
Final Order 2024-08-23
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(1): Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. a) Jobsite: On or about 6/5/2024, the employer did not ensure that the ladder-jack scaffold components were capable of supporting the weight transmitted to it.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260451 A06
Issuance Date 2024-07-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-23
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person. a) Jobsite, left side of house: On or about 6/5/2024, the employer did not ensure that the scaffold system was designed by a qualified person for the intended load. b) Jobsite, right side of house: On or about 6/5/2024, the employer did not ensure that the scaffold system was designed by a qualified person for the intended load.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19260451 B05 II
Issuance Date 2024-07-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-23
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a) Jobsite: On or about 6/5/2024, employees were exposed to fall hazards while working from scaffold platforms where the planks extended approximately 3 feet beyond their support.
Citation ID 01003D
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2024-07-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-23
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) Jobsite: On or about 6/5/2024, proper access within 2 feet of a ladder-jack scaffold platform was not provided.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260452 K01
Issuance Date 2024-07-24
Current Penalty 2903.4
Initial Penalty 4839.0
Final Order 2024-08-23
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(k)(1): Ladder jack scaffold platforms exceeded a height of 20 feet (6.1 m). a) Jobsite: On or about 6/5/2024, employees were exposed to fall hazards while working from a ladder-jack scaffold system that was approximately 24 feet above the ground level. b) Jobsite: On or about 6/5/2024, an employee was exposed to fall hazards while working from a ladder-jack scaffold system that was approximately 20 feet 9 inches above the ground level.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-07-24
Current Penalty 2903.4
Initial Penalty 4839.0
Final Order 2024-08-23
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a) Roof: On or about 6/5/2024, an employee was exposed to fall hazards of greater than 21 feet while performing residential roofing work without any means of fall protection.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19260502 D17
Issuance Date 2024-07-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-23
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head. a) Jobsite: On or about 6/5/2024, the employer did not ensure that personal fall arrest lanyards were connected to the center of the harness wearer's back.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2024-07-24
Current Penalty 2488.8
Initial Penalty 4148.0
Final Order 2024-08-23
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed. a) Jobsite: On or about 6/5/2024, employees were using a ladder as a scaffold platform.
Citation ID 01006B
Citaton Type Serious
Standard Cited 19261053 B09
Issuance Date 2024-07-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-23
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(9): The area around the top and/or bottom of (a) ladder(s) was not kept clear. a) Jobsite: On or about 6/5/2024, the employer did not ensure the area around the base of the ladder was kept clear.
Citation ID 02001
Citaton Type Other
Standard Cited 19260454 A
Issuance Date 2024-07-24
Abatement Due Date 2024-09-09
Current Penalty 232.8
Initial Penalty 388.0
Final Order 2024-08-23
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Jobsite: On or about 6/5/2024, the employer did not ensure that employees were trained to recognize the hazards associated with working on scaffolds.
Citation ID 02002
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2024-07-24
Abatement Due Date 2024-09-09
Current Penalty 232.8
Initial Penalty 388.0
Final Order 2024-08-23
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) Jobsite: On or about 6/5/2024, the employer did not create a written certification record verifying that employees received adequate fall protection training when exposed to fall hazards.

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
4237647 Interstate 2024-05-08 - - 1 1 Private(Property)
Legal Name NDL LANDSCAPING LLC
DBA Name -
Physical Address 186 ADMIRAL ST APT 3 , PROVIDENCE, RI, 02908-2640, US
Mailing Address 186 ADMIRAL ST APT 3 , PROVIDENCE, RI, 02908-2640, US
Phone (401) 699-7093
Fax -
E-mail NEHENIASDLU95@GMAIL.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 1
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 3
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 1
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 20
Number of inspections with at least one Driver Fitness BASIC violation 1
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 1
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 1

Inspections

Unique report number of the inspection 00DP003952
State abbreviation that indicates the state the inspector is from RI
The date of the inspection 2024-06-27
ID that indicates the level of inspection Driver-Only
State abbreviation that indicates where the inspection occurred RI
Time weight of the inspection 3
Number of Out-Of-Service violations related to Driver 1
Number of Out-Of-Service violations related to vehicle 0
Number of violations related to Hazardous Materials 0
Total number of Out-Of-Service violations 1
Total number of Out-Of-Service violations related to Hazardous Materials 0
Description of the type of the main unit STRAIGHT TRUCK
Description of the make of the main unit FORD
License plate of the main unit 1NJ366
License state of the main unit RI
Vehicle Identification Number of the main unit 1FDRF3HT2GEA87205
Description of the type of the secondary unit SEMI-TRAILER
Description of the make of the secondary unit TRLR
License plate of the secondary unit 3N804
License state of the secondary unit RI
Vehicle Identification Number of the secondary unit HMT55441813N804
Unsafe Driving BASIC inspection Y
Hours-of-Service Compliance BASIC inspection Y
Driver Fitness BASIC inspection Y
Controlled Substances/Alcohol BASIC inspection Y
Total number of BASIC violations 2
Number of Unsafe Driving BASIC violations 1
Number of Hours-of-Service Compliance BASIC violations 0
Number of Driver Fitness BASIC violations 1
Number of Controlled Substances/Alcohol BASIC violations 0
Number of Vehicle Maintenance BASIC violations 0
Number of Hazardous Materials Compliance BASIC violations 0

Violations

The date of the inspection 2024-06-27
Code of the violation 39282A1
Name of the BASIC Unsafe Driving
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 10
The time weight that is assigned to a violation 3
The description of a violation Using a hand-held mobile telephone while operating a CMV
The description of the violation group Phone Call
The unit a violation is cited against Driver
The date of the inspection 2024-06-27
Code of the violation 39141A1FPC
Name of the BASIC Driver Fitness
The violation is identified as Out-Of-Service violation Y
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 2
The severity weight that is assigned to a violation 1
The time weight that is assigned to a violation 3
The description of a violation Operating a property-carrying vehicle without possessing a valid medical certificate. Previously Cited on [DATE]
The description of the violation group Medical Certificate
The unit a violation is cited against Driver

Date of last update: 28 Oct 2024

Sources: Rhode Island Department of State