Search icon

CUENCA CONSTRUCTION INC

Company Details

Name: CUENCA CONSTRUCTION INC
Jurisdiction: Rhode Island
Entity type: Foreign Corporation
Status: Activ
Date of Organization in Rhode Island: 04 Aug 2021 (4 years ago)
Identification Number: 001727738
ZIP code: 02888
County: Kent County
Place of Formation: MASSACHUSETTS
Principal Address: 222 JEFFERSON BLVD, WARWICK, RI, 02888, USA
Purpose: CONSTRUCTION SERVICES

Industry & Business Activity

NAICS

238190 Other Foundation, Structure, and Building Exterior Contractors

This industry comprises establishments primarily engaged in building foundation and structure trades work (except poured concrete, structural steel, precast concrete, framing, masonry, glass and glazing, roofing, and siding). The work performed may include new work, additions, alterations, maintenance, and repairs. Learn more at the U.S. Census Bureau

Agent

Name Role Address
PARASEARCH, INC. Agent 222 JEFFERSON BOULEVARD SUITE 200, WARWICK, RI, 02888, USA

TREASURER

Name Role Address
ROLAND O YUNGA MOROCHO TREASURER 30 NEWPORT ST FALL RIVER , MA 02720 USA

SECRETARY

Name Role Address
ROLAND O YUNGA MOROCHO SECRETARY 30 NEWPORT ST FALL RIVER , MA 02720 USA

PRESIDENT

Name Role Address
ROLAND O. YUNGA MOROCHO PRESIDENT 30 NEWPORT STREET FALL RIVER, MA 02720 USA

DIRECTOR

Name Role Address
ROLAND O YUNGA MOROCHO DIRECTOR 30 NEWPORT ST FALL RIVER Q, MA 02720 USA

Filings

Number Name File Date
202342703830 Annual Report 2023-11-11
202225416950 Annual Report 2022-12-21
202208449230 Annual Report 2022-01-22
202199879120 Application for Certificate of Authority 2021-08-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345683445 0112300 2021-12-07 221 WATERMAN ST., PROVIDENCE, RI, 02906
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2022-03-03
Emphasis L: FALL
Case Closed 2024-12-02

Related Activity

Type Complaint
Activity Nr 1840102
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B03
Issuance Date 2022-04-26
Abatement Due Date 2022-05-13
Current Penalty 2175.5
Initial Penalty 4351.0
Contest Date 2022-08-12
Final Order 2022-11-02
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling: a) Jobsite: On or about 12/7/21, while four employees were working at height of approximately 20-25 feet, the employer did not ensure that the work platforms of the Alum-A-Pole scaffold were 14" or less from the face of the building.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B04
Issuance Date 2022-04-26
Abatement Due Date 2022-05-13
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2022-08-12
Final Order 2022-11-02
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(4): Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm) a) Jobsite: On or about 12/7/21,while four employees were working at height of approximately 20-25 feet, the employer did not ensure that the work platforms of the Alum-A-Pole scaffold extended at least six inches (6") past the centerline of support.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 B10
Issuance Date 2022-04-26
Abatement Due Date 2022-05-13
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2022-08-12
Final Order 2022-11-02
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(10): Scaffold components manufactured by different manufacturers were intermixed such that the components fit together with force and the scaffold's structural integrity was not maintained by the user: a) Jobsite: On or about 12/7/21,while four employees were working at height of approximately 20-25 feet, the employer did not ensure that the components of the Alum-A-Pole scaffold were compatible and erected properly. The scaffold was erected with chains, ropes, lumber, and Werner extension ladders.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2022-04-26
Abatement Due Date 2022-05-13
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2022-08-12
Final Order 2022-11-02
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: a) Jobsite: On or about 12/7/21, while four employees were working at height of approximately 20-25 feet, the employer did not ensure that the Alum-A-Pole scaffold was erected with base plates. The scaffolding was rested on the dirt ground.
Citation ID 01001E
Citaton Type Serious
Standard Cited 19260452 J02
Issuance Date 2022-04-26
Abatement Due Date 2022-05-13
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2022-08-12
Final Order 2022-11-02
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Jobsite: On or about 12/7/21, while four employees were working at height of approximately 20-25 feet, the employer did not ensure that the Alum-A-Pole scaffold was secured to the building with intermediate braces. The scaffold was about thirty feet (30') in height and only braced at the top of the building.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2022-04-26
Abatement Due Date 2022-05-13
Current Penalty 2175.5
Initial Penalty 4351.0
Contest Date 2022-08-12
Final Order 2022-11-02
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) Jobsite: On or about 12/7/21, while four employees were working at height of approximately 20-25 feet, the employer did not ensure that the Alum-A-Pole scaffold system was inspected daily by a competent person. The scaffold was erected with chains, ropes, lumber, and Werner extension ladders.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2022-04-26
Abatement Due Date 2022-05-13
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2022-08-12
Final Order 2022-11-02
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) Jobsite: On or about 12/7/21, while four employees were working at height of approximately 20-25 feet, the employer did not ensure that employees who erected the Alum-A-Pole scaffold were adequately trained and were working under the supervision or direction of a competent person.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2022-04-26
Abatement Due Date 2022-05-13
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2022-08-12
Final Order 2022-11-02
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Jobsite: On or about 12/7/21, while four employees were performing siding work, the employer did not ensure that the four employees working from the Alum-A-Pole scaffold, at a height greater than twenty-five feet (25'), were utilizing fall arrest systems or guardrail systems.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2022-04-26
Abatement Due Date 2022-05-13
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2022-08-12
Final Order 2022-11-02
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) Jobsite: On or about 12/7/21, while four employees were performing siding work, the employer did not ensure that these employees working at over twenty-five feet (25') in height, from an Alum-A-Pole Scaffold, were provided training in the hazards associated with this type of scaffold.
307575027 0112300 2005-09-13 WEST MAIN RD, PORTSMOUTH, RI, 02871
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2005-09-13
Emphasis L: FALL
Case Closed 2005-10-28

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2005-10-06
Abatement Due Date 2005-10-12
Current Penalty 750.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 2
Gravity 03
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2005-10-06
Abatement Due Date 2005-10-12
Current Penalty 750.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 2
Gravity 03