Search icon

J & G CONSTRUCTION, LLC

Company Details

Name: J & G CONSTRUCTION, LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Revoked Entity
Date of Organization in Rhode Island: 16 Sep 2020 (5 years ago)
Date of Dissolution: 11 Jan 2022 (3 years ago)
Date of Status Change: 11 Jan 2022 (3 years ago)
Identification Number: 001712872
ZIP code: 02860
County: Providence County
Principal Address: 657 WEEDEN ST, PAWTUCKET, RI, 02860, USA

Agent

Name Role Address
JOSE FERMIN ARIAS Agent 657 WEEDEN ST, PAWTUCKET, RI, 02860, USA

Filings

Number Name File Date
202207836860 Revocation Certificate For Failure to Maintain a Registered Office 2022-01-11
202102530250 Revocation Notice For Failure to Maintain a Registered Office 2021-10-04
202102375400 Registered Office Not Maintained 2021-09-24
202055319290 Articles of Organization 2020-09-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338076615 0112300 2013-01-02 1601 MINERAL SPRING, NORTH PROVIDENCE, RI, 02904
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2013-01-02
Emphasis L: FALL, P: FALL
Case Closed 2017-01-24

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-01-17
Current Penalty 2520.0
Initial Penalty 2520.0
Final Order 2013-02-12
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. Worksite: Fall protection was not used where employees were exposed to fall hazards.
307577965 0112300 2006-06-30 668 PARK AVENUE, CRANSTON, RI, 02910
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2006-06-30
Emphasis L: FALL
Case Closed 2016-04-12

Related Activity

Type Complaint
Activity Nr 205772973
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2006-07-13
Abatement Due Date 2006-07-19
Current Penalty 1500.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 4
Gravity 10
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2006-07-13
Abatement Due Date 2006-07-19
Nr Instances 1
Nr Exposed 4
Gravity 10
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260452 K01
Issuance Date 2006-07-13
Abatement Due Date 2006-07-19
Current Penalty 750.0
Initial Penalty 750.0
Nr Instances 2
Nr Exposed 4
Gravity 03
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2006-07-13
Abatement Due Date 2006-07-19
Nr Instances 2
Nr Exposed 4
Gravity 03

Date of last update: 28 Oct 2024