Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-03-22
|
Emphasis |
L: FALL, P: FALL
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2023-04-13 |
Current Penalty |
1992.2 |
Initial Penalty |
2846.0 |
Final Order |
2023-05-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns. a) Jobsite located at 153 Transit Street, Providence, RI 02906: On or about 3/22/2023, employees were not wearing protective helmets while working below individuals, on a pumpjack scaffold system, who were using power tools and wood overhead. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2023-04-13 |
Current Penalty |
3281.6 |
Initial Penalty |
4688.0 |
Final Order |
2023-05-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above a lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Jobsite located at 153 Transit Street, Providence, RI 02906: On or about 3/22/2023, the employer allowed an employee to work on a pump jack scaffold, approximately 30 feet above the lower level, without fall protection. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260452 J02 |
Issuance Date |
2023-04-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-05-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Jobsite located at 153 Transit Street, Providence, RI 02906: On or about 3/22/2023, the employer and an employee were working from a pump jack scaffold system without bottom bracing installed. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260454 A |
Issuance Date |
2023-04-13 |
Abatement Due Date |
2023-05-30 |
Current Penalty |
263.2 |
Initial Penalty |
376.0 |
Final Order |
2023-05-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Imminent Danger |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Jobsite located at 153 Transit Street, Providence, RI 02906: On or about 3/22/2023 and times prior, an employee did not receive training on the hazards, to include falls, associated with working from pump jack scaffolds. |
|
|