Search icon

MYNORS CONSTRUCTION LLC

Company Details

Name: MYNORS CONSTRUCTION LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Activ
Date of Organization in Rhode Island: 16 Apr 2019 (6 years ago)
Identification Number: 001695128
ZIP code: 02907
County: Providence County
Principal Address: 260 ELMWOOD AVE, PROVIDENCE, RI, 02907, USA
Purpose: RESIDENTIAL REMODELER

Industry & Business Activity

NAICS

236118 Residential Remodelers

This U.S. industry comprises establishments primarily responsible for the remodeling construction (including additions, alterations, reconstruction, maintenance, and repairs) of houses and other residential buildings, single-family and multifamily. Included in this industry are remodeling general contractors, for-sale remodelers, remodeling design-build firms, and remodeling project construction management firms. Learn more at the U.S. Census Bureau

Agent

Name Role Address
MYNOR ALINADO Agent 260 ELMWOOD AVE, PROVIDENCE, RI, 02907, USA

Filings

Number Name File Date
202450365720 Annual Report 2024-04-08
202339459940 Statement of Change of Registered/Resident Agent Office 2023-07-14
202339459760 Annual Report 2023-07-13
202337926660 Revocation Notice For Failure to File An Annual Report 2023-06-16
202218421990 Annual Report 2022-06-09
202106938980 Annual Report 2021-12-10
202106765630 Revocation Notice For Failure to File An Annual Report 2021-12-03
202103288150 Statement of Change of Registered/Resident Agent Office 2021-10-15
202195098570 Annual Report 2021-03-30
202194583680 Revocation Notice For Failure to File An Annual Report 2021-03-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347133084 0112300 2023-11-30 292 1/2 SIMMONSVILLE ROAD, JOHNSTON, RI, 02919
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-11-30
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2024-01-03
Current Penalty 2344.3
Initial Penalty 3349.0
Final Order 2024-01-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. (a) Worksite: On or about 11-30-2023, employees were not utilizing head protection while working below roofers, exposing them to struck-by hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-01-03
Current Penalty 3281.6
Initial Penalty 4688.0
Final Order 2024-01-16
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection measure under another provision of paragraph 1926.501(b). (a) Worksite: On or about 11-30-2023, employees were exposed to fall hazards during residential roofing from an approximate height of 15 feet above the lower level, without any means of fall protection.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-01-03
Current Penalty 2344.3
Initial Penalty 3349.0
Final Order 2024-01-16
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. (a) Worksite: On or about 11-30-2023, employees were accessing a residential roof using a 20-foot Werner extension ladder, where its side rails did not extend at least 3 feet above the upper landing surface being accessed, thus exposing employees to fall hazards.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261053 B10
Issuance Date 2024-01-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-01-16
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(10): The tops of a non-self-supporting ladder were not placed with the two rails supported equally. (a) Worksite: On or about 11-30-2023, employees were accessing a residential roof using a 20-foot Werner extension ladder with its two rails set unequally on the downward slope of a pitched roof, causing it to be unstable, thus exposing employees to fall hazards.
347040438 0112300 2023-10-18 1705 HARTFORD AVENUE, JOHNSTON, RI, 02919
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-10-18
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2024-01-11
Abatement Due Date 2024-02-28
Current Penalty 5156.0
Initial Penalty 5156.0
Final Order 2024-02-07
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) Worksite at 1705 Hartford Avenue Johnston, RI: On or about October 18, 2023, employees were exposed to fall hazards of approximately 11 feet 1 inch while performing roofing work on a 5/12 pitch roof without adequate fall protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-01-11
Abatement Due Date 2024-02-28
Current Penalty 5156.0
Initial Penalty 5156.0
Final Order 2024-02-07
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Worksite at 1705 Hartford Avenue Johnston, RI: On or about October 18, 2023, the employer did not provide adequate training for the employees who were performing roofing work and exposed to fall hazards.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-01-11
Abatement Due Date 2024-02-28
Current Penalty 5156.0
Initial Penalty 5156.0
Final Order 2024-02-07
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Worksite at 1705 Hartford Avenue Johnston, RI: On or about October 18, 2023, employees were not protected from falling while using a ladder that did not extend at least three feet above the upper landing surface on the roof.
Citation ID 02001A
Citaton Type Other
Standard Cited 19030019 C01
Issuance Date 2024-04-29
Abatement Due Date 2024-05-31
Current Penalty 388.0
Initial Penalty 388.0
Final Order 2024-05-28
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: (a) Establishment: As of April 29, 2024, the employer had not certified to OSHA that the abatement had been completed for Citation 1, Items 1, 2, and 3 from inspection number 1704043, issued on 1/11/2024, with a final order date of 2/7/2024.
Citation ID 02001B
Citaton Type Other
Standard Cited 19030019 D01
Issuance Date 2024-04-29
Abatement Due Date 2024-05-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-05-28
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. (a) Establishment: As of April 29, 2024, the employer had not provided the required abatement documentation to OSHA for Citation 1, Items 1, 2, and 3 from inspection number 1704043, issued on 1/11/2024, with a final order date of 2/7/2024.