Search icon

AMERICA PRO BUILDES INC

Company Details

Name: AMERICA PRO BUILDES INC
Jurisdiction: Rhode Island
Entity type: Foreign Corporation
Status: Activ
Date of Organization in Rhode Island: 20 Jul 2018 (7 years ago)
Identification Number: 001686503
Place of Formation: MASSACHUSETTS
Principal Address: 301 NEPTUNE STREET, FALL RIVER, MA, 02721, USA
Purpose: CONSTRUCTION
Historical names: America Pro Construction Inc.

Industry & Business Activity

NAICS

236118 Residential Remodelers

This U.S. industry comprises establishments primarily responsible for the remodeling construction (including additions, alterations, reconstruction, maintenance, and repairs) of houses and other residential buildings, single-family and multifamily. Included in this industry are remodeling general contractors, for-sale remodelers, remodeling design-build firms, and remodeling project construction management firms. Learn more at the U.S. Census Bureau

Agent

Name Role Address
PARASEARCH, INC. Agent 222 JEFFERSON BOULEVARD SUITE 200, WARWICK, RI, 02888, USA

PRESIDENT

Name Role Address
MAGNO SOUZA DE JESUS PRESIDENT 301 NEPTUNE STREET FALL RIVER, MA 02721 USA

TREASURER

Name Role Address
MAGNO SOUZA DE JESUS TREASURER 301 NEPTUNE ST FALL RIVER , MA 02721 USA

SECRETARY

Name Role Address
MAGNO SOUZA DE JESUS SECRETARY 301 NEPTUNE ST FALL RIVER, MA 02721 USA

DIRECTOR

Name Role Address
MAGNO SOUZA DE JESUS DIRECTOR 301 NEPTUNE ST FALL RIVER , MA 02721 USA

Events

Type Date Old Value New Value
Name Change 2024-10-16 America Pro Construction Inc. AMERICA PRO BUILDES INC

Filings

Number Name File Date
202460666860 Application for Amended Certificate of Authority 2024-10-16
202342869130 Annual Report 2023-11-21
202339454530 Annual Report 2023-07-13
202338185840 Revocation Notice For Failure to File An Annual Report 2023-06-19
202209680830 Annual Report 2022-02-08
202191699410 Annual Report 2021-02-16
202191699690 Annual Report 2021-02-16
202191699780 Statement of Change of Registered/Resident Agent 2021-02-16
202191699870 Annual Report 2021-02-16
202191699050 Reinstatement 2021-02-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346546013 0112300 2023-03-06 580 ADMIRAL STREET, PROVIDENCE, RI, 02908
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2023-06-23
Emphasis L: FALL

Related Activity

Type Complaint
Activity Nr 2006261
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2023-07-06
Abatement Due Date 2023-07-31
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-08-14
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. (a) Work Site: On or about 3/6/2023, employees were observed using ladders in near proximity to an electrical power line and these employees had not been trained in the recognition and avoidance of potential shock and fall hazards.
Citation ID 02001A
Citaton Type Other
Standard Cited 19030019 C01
Issuance Date 2023-09-08
Abatement Due Date 2023-10-12
Current Penalty 376.0
Initial Penalty 376.0
Final Order 2023-10-05
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: (a) Establishment: As of September 8, 2023, the employer had not certified to OSHA that the abatement had been completed for Citation 1, Item 1 from inspection number 1654601, issued on 7/6/2023, with a final order date of 8/14/2023.
Citation ID 02001B
Citaton Type Other
Standard Cited 19030019 D01
Issuance Date 2023-09-08
Abatement Due Date 2023-10-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-10-05
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. (a) Establishment: As of September 8, 2023, the employer had not provided the required abatement documentation to OSHA for Citation 1, Item 1 from inspection number 1654601, issued on 7/6/2023, with a final order date of 8/14/2023.
345915920 0112300 2022-04-22 30 NIPMUC TRAIL UNITS C/D, NORTH PROVIDENCE, RI, 02904
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2022-04-22
Case Closed 2022-05-02

Related Activity

Type Complaint
Activity Nr 1887190
Safety Yes
344925359 0112300 2020-09-14 153 BISHOP AVE., EAST PROVIDENCE, RI, 02914
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2020-09-14
Emphasis L: FALL
Case Closed 2022-06-30

Related Activity

Type Referral
Activity Nr 1659211
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2021-02-11
Abatement Due Date 2021-03-09
Current Penalty 2000.0
Initial Penalty 4096.0
Final Order 2021-03-10
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Jobsite, roof at entry on front side of two-story house: On or about September 14, 2020, two employees were exposed to a fall hazard of approximately 12-feet to the ground while performing siding work, standing and walking on the roof, and were not provided with, nor using, fall protection.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2021-02-11
Abatement Due Date 2021-03-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-03-10
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed. (a) Jobsite, Roof at entry front side of a two-story house: On or about September 14, 2020, two employees performing siding work were each working off of step ladders in the closed position which were set up on the entry roof diagonally, resting the top step on the next roof, exposing them to a fall hazard of approximately 12 feet.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2021-02-11
Abatement Due Date 2021-03-09
Current Penalty 2000.0
Initial Penalty 4096.0
Final Order 2021-03-10
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Jobsite, left side of a two-story house: On or about September 14, 2020, two employees were exposed to a fall hazard of approximate 11-feet while accessing a roof from an extension ladder, where the side rails of the ladder did not extend 3 feet above the roof landing surface.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2021-02-11
Abatement Due Date 2021-03-09
Current Penalty 0.0
Initial Penalty 4096.0
Final Order 2021-03-10
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: (a) Jobsite, two-story house: On or about September 14, 2020, the employer did not provide an adequate training program for the 2 employees who were using extension and step ladders to enable each employee to recognize the fall hazards of approximately 12 feet while accessing and performing siding work on a roof at the entry.
Citation ID 02001A
Citaton Type Other
Standard Cited 19030019 C01
Issuance Date 2021-04-27
Abatement Due Date 2021-06-01
Current Penalty 329.0
Initial Penalty 329.0
Final Order 2021-05-21
Nr Instances 4
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: (a) Establishment: As of April 27, 2021, the employer had not certified to OSHA that the abatement had been completed for Citation 1, Items 1a, 1b, 2, and 3 from inspection number 1492535, issued on 02/11/2021, with a final order date of 03/10/2021.
Citation ID 02001B
Citaton Type Other
Standard Cited 19030019 D01
Issuance Date 2021-04-27
Abatement Due Date 2021-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-05-21
Nr Instances 3
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(d)(1):The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: (a) Establishment: As of April 27, 2021, the employer had not provided the required abatement documentation to OSHA for Citation 1, Items 1a, 2, and 3 from inspection number 1492535, issued on 02/11/2021, with a final order date of 03/10/2021.

Date of last update: 27 Oct 2024

Sources: Rhode Island Department of State