Search icon

Seaport Masonry, Inc.

Company Details

Name: Seaport Masonry, Inc.
Jurisdiction: Rhode Island
Entity type: Foreign Corporation
Status: Activ
Date of Organization in Rhode Island: 29 Mar 2018 (7 years ago)
Identification Number: 001682948
Place of Formation: MASSACHUSETTS
Principal Address: 45 INDUSTRIAL ROAD, WRENTHAM, MA, 02093, USA
Purpose: MASONARY

Agent

Name Role Address
PARASEARCH, INC. Agent 222 JEFFERSON BOULEVARD SUITE 200, WARWICK, RI, 02888, USA

PRESIDENT

Name Role Address
DONALD GIBSON PRESIDENT 129 DEAN AVENUE FRANKLIN, MA 02038 USA

DIRECTOR

Name Role Address
JENNA GIBSON DIRECTOR 412 VILLAGE STREET MILLIS, MA 02054 USA

Filings

Number Name File Date
202457797010 Annual Report 2024-07-10
202457241360 Revocation Notice For Failure to File An Annual Report 2024-06-25
202339375790 Annual Report 2023-07-10
202338180700 Revocation Notice For Failure to File An Annual Report 2023-06-19
202209594290 Annual Report 2022-02-07
202193410590 Annual Report 2021-03-02
202034491740 Annual Report 2020-02-13
201917387130 Annual Report 2019-09-03
201907240780 Revocation Notice For Failure to File An Annual Report 2019-07-24
201984742940 Statement of Change of Registered/Resident Agent 2019-01-18

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346125057 0112300 2022-08-04 1221 POST ROAD, WARWICK, RI, 02888
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2022-08-04
Emphasis L: FALL, N: HEATNEP
Case Closed 2024-12-17

Related Activity

Type Complaint
Activity Nr 1929243
Safety Yes
Health Yes
Type Inspection
Activity Nr 1612502
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C
Issuance Date 2022-12-05
Abatement Due Date 2023-01-23
Current Penalty 2734.8
Initial Penalty 4558.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use. (a) At the worksite: On or about 8/4 2022, the employer allowed employees to use a gas powered saw to cut concrete block, and did not develop and implement a written respiratory protection program with site specific procedures and elements for required respirator use.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2022-12-05
Abatement Due Date 2023-01-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. (a) At the worksite: On or about 8/4 2022, employees were exposed to upper respiratory type illnesses from wearing 3M N95 filtering facepiece respirators without undergoing a medical evaluation to determine their ability to wear respiratory protection.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 F01
Issuance Date 2022-12-05
Abatement Due Date 2023-01-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT). (a) At the worksite: On or about 8/4 2022, the employer did not ensure that employees required to wear an N95 filtering facepiece respirator passed a qualitative (QLFT) or quantitative fit test (QNFT) before requiring the employee to wear the 3M, 8210 N95 mask.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100134 K01
Issuance Date 2022-12-05
Abatement Due Date 2023-01-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(1): The employer did not provide respirator training that would ensure each employee could demonstrate knowledge of items in section (i)-(vii). (a) At the worksite: On or about 8/4 2022, the employer did not provide respirator training to employees to ensure they could demonstrate knowledge of section 134(k)(1)(i)-(vii) in that, employees did not recognize the importance of wearing respiratory protection while cutting concrete blocks with a potential exposure to silica dust hazards.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 A06
Issuance Date 2022-12-05
Abatement Due Date 2022-12-29
Current Penalty 3828.6
Initial Penalty 6381.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(6): Scaffolds were not constructed in accordance with the design by a qualified person. (a) At the worksite: On or about 8/4/2022, the employer allowed employees to work from a scaffold that was not constructed in accordance with the design by a qualified person in that, portions of the scaffold had unguarded areas, which exposed employees to fall hazards of approximately 13' 6".
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2022-12-05
Abatement Due Date 2022-12-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii). (a) At the worksite: On or about 8/4/2022, the employer did not ensure that each platform on the scaffold system was fully planked or decked between the uprights and the guardrail supports, exposing employees to a fall hazard of approximately 13' 6".
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2022-12-05
Abatement Due Date 2022-12-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. (a) At the worksite: On or about 8/4/2022, the employer did not ensure that the scaffold system was inspected for visible defects by a competent person in that, there were multiple instances of missing cross-bar members, scaffold decks not fully planked between the uprights, scaffold components not adequately attached or affixed, which exposed employees to fall hazards of approximately 13' 6".
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2022-12-05
Abatement Due Date 2023-01-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees selected by, and under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. (a) At the worksite: On or about 8/4/2022, employees were exposed to fall hazards from working on a scaffold system that was not erected, moved or altered by trained experienced employees under the supervision/direction of a competent person qualified in scaffold erection.
Citation ID 01002E
Citaton Type Serious
Standard Cited 19260451 G01 V
Issuance Date 2022-12-05
Abatement Due Date 2022-12-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(v): Each employee on a walkway located within a scaffold was not protected by a guardrail system (with a minimum 200 pound top-rail capacity) installed within 9.5 inches (24.1 cm) of and along at least one side of the walkway. (a) At the worksite: On or about 8/4/2022, employees working from a scaffold were not protected by a guardrail system installed within 9.5 inches of and along one side of the walkway, exposing the employees to a fall hazard of approximately 13' 6".
Citation ID 01003
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2022-12-05
Abatement Due Date 2022-12-29
Current Penalty 3828.6
Initial Penalty 6381.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally. (a) At the worksite: On or about 8/4 2022, employees were exposed to fall hazards of approximately 13' 6" while performing work from the upper level of a tubular welded frame scaffold system that was not fully supported by securing vertical members together laterally with cross bracing.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2022-12-05
Abatement Due Date 2023-01-23
Current Penalty 2187.6
Initial Penalty 3646.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) At the worksite: On or about 8/4 2022, the employer allowed employees to work from a scaffold system without adequate training by a competent person to recognize the hazards associated with scaffolds, which exposed employees to fall hazards of approximately 13' 6".
Citation ID 01005A
Citaton Type Serious
Standard Cited 19261153 C01
Issuance Date 2022-12-05
Abatement Due Date 2022-12-29
Current Penalty 2734.8
Initial Penalty 4558.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1. (a) At the worksite: On or about 8/4 2022, the employer allowed employees to cut concrete block, which is identified in table 1, and did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, exposing the employees to the hazards of silica dust hazards.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19261153 E02
Issuance Date 2022-12-05
Abatement Due Date 2023-01-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-12-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1153(e)(2): Where respirator use is required by this section, the employer did not institute a respiratory protection program in accordance with 29 CFR 1910.134. (a) At the worksite: On or about 8/4 2022, the employer required the use of respirators and did not institute a respiratory protection program in accordance with the requirements of 1910.134, exposing employees to silica dust hazards.