Name: | Scott James Furniture & Design, Inc. |
Jurisdiction: | Rhode Island |
Entity type: | Domestic Profit Corporation |
Status: | Activ |
Date of Organization in Rhode Island: | 03 Mar 2017 (8 years ago) |
Identification Number: | 001671497 |
ZIP code: | 02878 |
County: | Newport County |
Principal Address: | 381 STATE AVENUE, TIVERTON, RI, 02878, USA |
Purpose: | FURNITURE DESIGN AND ASSEMBLY |
NAICS
337122 Nonupholstered Wood Household Furniture ManufacturingThis U.S. industry comprises establishments primarily engaged in manufacturing nonupholstered wood household-type furniture and freestanding cabinets (except television, stereo, and sewing machine cabinets). The furniture may be made on a stock or custom basis and may be assembled or unassembled (i.e., knockdown). Learn more at the U.S. Census Bureau
Name | Role | Address |
---|---|---|
CRISTINA M. OFFENBERG, ESQ. | Agent | 1100 AQUIDNECK AVENUE, MIDDLETOWN, RI, 02842, USA |
Name | Role | Address |
---|---|---|
SCOTT PACHECO | PRESIDENT | 381 STATE AVENUE TIVERTON, RI 02878 USA |
Name | Role | Address |
---|---|---|
SCOTT PACHECO | TREASURER | 381 STATE AVENUE TIVERTON, RI 02878 USA |
Name | Role | Address |
---|---|---|
SCOTT PACHECO | SECRETARY | 381 STATE AVENUE TIVERTON, RI 02878 USA |
Name | Role | Address |
---|---|---|
SCOTT PACHECO | VICE PRESIDENT | 381 STATE AVENUE TIVERTON, RI 02878 USA |
Number | Name | File Date |
---|---|---|
202447971990 | Annual Report | 2024-03-06 |
202333011900 | Annual Report | 2023-04-14 |
202211467940 | Annual Report | 2022-02-23 |
202192584580 | Annual Report | 2021-02-23 |
202034859630 | Annual Report | 2020-02-21 |
201987496480 | Annual Report | 2019-02-25 |
201859327520 | Annual Report | 2018-02-28 |
201737281740 | Articles of Incorporation | 2017-03-03 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345199269 | 0112300 | 2021-03-16 | 381 STATE AVENUE, TIVERTON, RI, 02878 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1746681 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 A03 II |
Issuance Date | 2021-07-20 |
Abatement Due Date | 2021-08-12 |
Current Penalty | 4204.9 |
Initial Penalty | 6007.0 |
Final Order | 2021-08-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: (a) Production area: On or about 3/15/2021, the employer did not ensure that the point of operation on the MAXYM Tenoner cutting machine was guarded, resulting in an employee suffering a serious hand injury from coming in contact with the cutting blade while operating the machine. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100132 D02 |
Issuance Date | 2021-07-20 |
Abatement Due Date | 2021-08-12 |
Current Penalty | 4204.9 |
Initial Penalty | 6007.0 |
Final Order | 2021-08-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: (a) Production area: On or about 3/16/2021, the employer did not verify, through a written certification, that a hazard assessment of the workplace was performed prior to employees operating the tenon cutting machine. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2018-04-25 |
Emphasis | L: EISAOF, L: EISAX50, N: AMPUTATE, N: DUSTEXPL, P: AMPUTATE |
Case Closed | 2018-06-26 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100022 A01 |
Issuance Date | 2018-05-01 |
Abatement Due Date | 2018-06-15 |
Current Penalty | 3141.0 |
Initial Penalty | 3141.0 |
Final Order | 2018-05-22 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition: (a) Worksite: On or about 4/25/2018, the woodworking shop area, where wood boards are machine sanded, cut and drilled, had explosive wood dust build-up on the floor, the walls, overhead pipes, duct work, light fixtures and other surrounding surfaces. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19100134 E01 |
Issuance Date | 2018-05-01 |
Abatement Due Date | 2018-06-15 |
Current Penalty | 39.0 |
Initial Penalty | 2513.0 |
Final Order | 2018-05-22 |
Nr Instances | 2 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Worksite: On or about 4/25/2018, the employer did not ensure that employees underwent a medical evaluation for the use of a half mask air purifying respirator and for the required use of N95 dust mask respirators. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19100134 F01 |
Issuance Date | 2018-05-01 |
Abatement Due Date | 2018-06-15 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-05-22 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting face-piece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) Worksite: On or about 4/25/2018, the employer did not ensure that employees wearing a half mask air purifying respirator while applying finishing coats to wood products were fit tested for the respirator being worn. |
Citation ID | 01002C |
Citaton Type | Serious |
Standard Cited | 19100134 K03 |
Issuance Date | 2018-05-01 |
Abatement Due Date | 2018-06-15 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-05-22 |
Nr Instances | 2 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: (a) Worksite: On or about 4/25/2018, the employer did not ensure that employees who are required to wear both a half mask air purifying respirator and N95 dust mask respirators, were trained in the use and care of the respirator prior to its actual use. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100147 C04 I |
Issuance Date | 2018-05-01 |
Abatement Due Date | 2018-06-15 |
Current Penalty | 0.0 |
Initial Penalty | 353.0 |
Final Order | 2018-05-22 |
Nr Instances | 3 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Worksite: On or about 4/25/2018, the employer did not ensure that machine specific Lockout/Tag-out procedures were developed to isolate both electric and pneumatic energy sources. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100178 Q07 |
Issuance Date | 2018-05-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-05-22 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: (a) Worksite: On or about 4/25/2018, the employer did not ensure that employees performed an inspection on each day the forklift was operated. |
Citation ID | 02003 |
Citaton Type | Other |
Standard Cited | 19101200 H01 |
Issuance Date | 2018-05-01 |
Abatement Due Date | 2018-06-15 |
Current Penalty | 0.0 |
Initial Penalty | 353.0 |
Final Order | 2018-05-22 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Worksite - Finishing Room: On or about 4/25/2018, the employer did not ensure that each employee working in the finishing room was trained in hazard communication. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9369197202 | 2020-04-28 | 0165 | PPP | 381 STATE AVENUE, TIVERTON, RI, 02878 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 26 Oct 2024
Sources: Rhode Island Department of State