Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-07-06
|
Emphasis |
L: FALL
|
Case Closed |
2023-10-17
|
Related Activity
Type |
Complaint |
Activity Nr |
1783303 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1540173 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 A06 |
Issuance Date |
2021-10-12 |
Abatement Due Date |
2021-11-04 |
Current Penalty |
2867.2 |
Initial Penalty |
4096.0 |
Final Order |
2021-10-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(a)(6): Scaffolds were not constructed in accordance with the design by a qualified person: (a) At the worksite: On or about 7/6/2021, employees were exposed to collapse and fall hazards from working on a scaffold system that was assembled using parts from a ladder jack scaffold and a pump jack scaffold, and held together with tie-down straps and plywood. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2021-10-12 |
Abatement Due Date |
2021-11-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) At the back corner of the house: On or about 7/6/2021, the employer did not ensure that a competent person inspected the scaffold system for visible defects, in that the scaffolding was assembled using two different scaffold types and was held together with plywood and tie down straps. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2021-10-12 |
Abatement Due Date |
2021-11-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: (a) At the back corner of the house: On or about 7/6/2021, the employer did not have the scaffolding system erected by a competent person qualified in scaffold erection, resulting in different scaffold types combined into one system. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19260452 J02 |
Issuance Date |
2021-10-12 |
Abatement Due Date |
2021-11-04 |
Current Penalty |
0.0 |
Initial Penalty |
4096.0 |
Final Order |
2021-10-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: (a) On the west side of the house: On or about 7/6/2021, the employer did not ensure that the pump jack scaffold poles were secured at the bottom. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260454 A |
Issuance Date |
2021-10-12 |
Abatement Due Date |
2021-11-29 |
Current Penalty |
2867.2 |
Initial Penalty |
4096.0 |
Final Order |
2021-10-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: (a) At the worksite: On or about 7/6/2021, the employer did not ensure that employees were trained by a qualified person to recognize the hazards associated with this type of scaffold system, and the procedures to minimize risk. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260454 B |
Issuance Date |
2021-10-12 |
Abatement Due Date |
2021-11-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: (a) At the worksite: On or about 7/6/2021, the employer did not have each employee involved in erecting, operating, repairing, maintaining, or inspecting the scaffolding system trained by a competent person to recognize the hazards associated with these work activities. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2021-10-12 |
Current Penalty |
2867.2 |
Initial Penalty |
4096.0 |
Final Order |
2021-10-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level: (a) At the back of the house: On or about 7/6/2021, employees were exposed to fall hazards from a scaffold system at a height of approximately 14 feet above the lower level, without adequate fall protection. |
|
|