Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-11-19
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2019-06-12
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 B05 II |
Issuance Date |
2019-01-03 |
Current Penalty |
2216.0 |
Initial Penalty |
3880.0 |
Final Order |
2019-01-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end: Worksite: The platform of the pump jack scaffold, which was greater than 10 feet in length, extended more than 18 inches over the support of the pump jack scaffold pole, and was not secured to prevent tipping or had guardrails which blocked employee access. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2019-01-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-01-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: Worksite: The fabricated frame and pump jack scaffolds in use on the jobsite were not inspected for visible defects by a competent person before each work shift, such as but not limited to the lack of fall protection, lack of bracing at the bottom pole of the pump jack scaffold, and the fabricated frame scaffold being used to support one end of the pump jack scaffold. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2019-01-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-01-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Worksite: Guardrails or equivalent means of fall protection was not used by employees working from a fabricated framed scaffold 18 feet above the ground. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19260452 J02 |
Issuance Date |
2019-01-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-01-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. Worksite: The pump jack scaffold pole of the scaffold in use on the jobsite was not secured to the structure with a brace or equivalent. |
|
|