Search icon

KM CONSTRUCTION AND LANDSCAPING, LLC

Company Details

Name: KM CONSTRUCTION AND LANDSCAPING, LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Activ
Date of Organization in Rhode Island: 28 Feb 2014 (11 years ago)
Identification Number: 000910526
ZIP code: 02920
County: Providence County
Principal Address: 24 BYRON STREET, CRANSTON, RI, 02920, USA
Mailing Address: 1165 ELMWOOD AVENUE PROVIDENCE RI 02907, PROVIDENCE, RI, 02907, USA
Purpose: RESIDENTIAL REMODELING AND REPAIRS
Historical names: KM CONSTRUCTION, LLC

Agent

Name Role Address
JOSE TAVERAS Agent 1165 ELMWOOD AVE, PROVIDENCE, RI, 02907, USA

Events

Type Date Old Value New Value
Name Change 2014-09-08 KM CONSTRUCTION, LLC KM CONSTRUCTION AND LANDSCAPING, LLC

Filings

Number Name File Date
202453791850 Annual Report 2024-05-02
202327361040 Annual Report 2023-02-04
202211224110 Annual Report 2022-02-20
202104771570 Statement of Change of Registered/Resident Agent 2021-11-05
202104770960 Annual Report 2021-11-05
202034115600 Annual Report 2020-02-11
202034116030 Annual Report 2020-02-11
202034116300 Annual Report 2020-02-11
202034115420 Reinstatement 2020-02-11
201906386650 Revocation Certificate For Failure to File the Annual Report for the Year 2019-07-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344529946 0112300 2019-12-26 17 CROMWELL ST., PROVIDENCE, RI, 02907
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2019-12-26
Emphasis L: FALL
Case Closed 2019-12-27

Related Activity

Type Complaint
Activity Nr 1529421
Safety Yes
340095744 0112300 2014-11-20 1800 MENDON ROAD, CUMBERLAND, RI, 02864
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2014-11-20
Emphasis L: FALL
Case Closed 2016-10-03

Related Activity

Type Referral
Activity Nr 923094
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2014-12-16
Abatement Due Date 2015-01-09
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2015-01-12
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: Jobsite, vehicle loading bay: An employee was working from a non-self-supporting ladder whereby the angle between the horizontal distances from the top support to the foot of the ladder was greater than approximately one-quarter of the working length of the ladder.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261053 B07
Issuance Date 2014-12-16
Abatement Due Date 2015-01-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-12
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(7): Ladder(s) that were unsecured or not provided with slip-resistant feet were used on slippery surfaces: Jobsite, vehicle loading bay: An employee was using the upper section of extension ladder to conduct work on the structure whereby the ladder section did not have slip-resistant feet attached to prevent accidental displacement.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2014-12-16
Abatement Due Date 2015-02-02
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2015-01-12
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: Establishment: The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways.
339868309 0112300 2014-07-24 1800 MENDON RD, CUMBERLAND, RI, 02864
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-07-24
Emphasis L: FALL, P: FALL
Case Closed 2019-09-30

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2014-08-13
Abatement Due Date 2014-08-28
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2014-09-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) Jobsite: A worker performing roofing work, at a height of approximately 15 feet from the ground, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system, for a jobsite located in Cumberland RI on or about 7-24-14.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-08-13
Abatement Due Date 2014-08-28
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2014-09-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Jobsite: The side rails of the aluminum ladder, which was being used to access the roof, did not extend at least 3 feet above the upper landing surface, for a jobsite located in Cumberland RI on or about 7-24-14.

Date of last update: 18 Oct 2024