340964121
|
0112300
|
2015-10-06
|
636 THAMES ST., NEWPORT, RI, 02840
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-10-06
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2016-03-11
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260025 A |
Issuance Date |
2016-02-17 |
Current Penalty |
0.0 |
Initial Penalty |
1200.0 |
Final Order |
2016-03-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures. Worksite: Construction debris was not kept clear of the working areas and entrances of the new building. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2016-02-17 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-03-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Worksite: Guardrails were not provided on the pump jack scaffold where the working platform was more than 10 feet. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-02-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-03-11 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Worksite: Open stairwells on the jobsite were not protected by guardrail systems. |
|
|
340964501
|
0112300
|
2015-10-06
|
636 THAMES STREET, NEWPORT, RI, 02840
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-10-06
|
Case Closed |
2016-03-11
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19101200 G08 |
Issuance Date |
2016-02-17 |
Abatement Due Date |
2016-03-04 |
Current Penalty |
0.0 |
Initial Penalty |
1200.0 |
Final Order |
2016-03-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s): Worksite: When employees were exposed to hazardous roofing cements and sealants while conducting construction activities, the employer did not ensure that Material Safety Data Sheets for these chemicals were maintained in the workplace and readily accessible during each work shift when the employees, and other workers are in their work areas(s). |
|
|