Name: | Biszko Contracting Corp. |
Jurisdiction: | Rhode Island |
Entity type: | Foreign Corporation |
Status: | Activ |
Date of Organization in Rhode Island: | 25 Sep 2012 (13 years ago) |
Identification Number: | 000793381 |
Place of Formation: | MASSACHUSETTS |
Principal Address: | 20 DEVELOPMENT STREET, FALL RIVER, MA, 02721, USA |
Purpose: | UNDERGROUND UTILITY CONSTRUCTION |
NAICS
237110 Water and Sewer Line and Related Structures ConstructionThis industry comprises establishments primarily engaged in the construction of water and sewer lines, mains, pumping stations, treatment plants, and storage tanks. The work performed may include new work, reconstruction, rehabilitation, and repairs. Specialty trade contractors are included in this industry if they are engaged in activities primarily related to water, sewer line, and related structures construction. All structures (including buildings) that are integral parts of water and sewer networks (e.g., storage tanks, pumping stations, water treatment plants, and sewage treatment plants) are included in this industry. Learn more at the U.S. Census Bureau
Name | Role | Address |
---|---|---|
ALAN C. BISZKO | Agent | 20 N. GEDSBY LANE, TIVERTON, RI, 02878, USA |
Name | Role | Address |
---|---|---|
ALAN C BISZKO | PRESIDENT | 20 N GADSBY LANE TIVERTON, RI 02878 USA |
Name | Role | Address |
---|---|---|
MICHAEL BISZKO JR | CLERK | 49 N COURT TIVERTON, RI 02878 USA |
Name | Role | Address |
---|---|---|
MICHAEL BISZKO III | DIRECTOR | 17 SANDPIPER DR WESTPORT, MA 02790 USA |
Number | Name | File Date |
---|---|---|
202447899050 | Annual Report | 2024-03-06 |
202329899910 | Annual Report | 2023-03-03 |
202212582110 | Annual Report | 2022-03-10 |
202188095010 | Annual Report | 2021-01-28 |
202035146270 | Annual Report | 2020-02-25 |
201986744050 | Annual Report | 2019-02-15 |
201855511310 | Annual Report | 2018-01-02 |
201610536510 | Annual Report | 2016-10-18 |
201589118230 | Annual Report | 2015-12-14 |
201555336600 | Annual Report | 2015-02-19 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
337696710 | 0112300 | 2012-12-06 | BLISS MINE ROAD, NEWPORT, RI, 02840 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 694192 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260651 J01 |
Issuance Date | 2013-05-06 |
Abatement Due Date | 2013-05-08 |
Current Penalty | 0.0 |
Initial Penalty | 1020.0 |
Contest Date | 2013-05-14 |
Final Order | 2013-08-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(j)(1): Adequate protection was not provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face: Jobsite: On or about 12/06/2012, adequate protection was not provided to protect employees from loose rock or soil whereby an employee was exposed to loose rocks in the sidewall of the trench. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2013-05-06 |
Abatement Due Date | 2013-05-08 |
Current Penalty | 0.0 |
Initial Penalty | 1020.0 |
Contest Date | 2013-05-14 |
Final Order | 2013-08-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). Jobsite: On or about 12/06/2012, an employee working in an excavation was not adequately protected from cave-ins in that the trench box was placed approximately 15 inches below the surface of the excavation. |
Inspection Type | Complaint |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1991-09-26 |
Emphasis | N: TRENCH |
Case Closed | 1992-10-13 |
Related Activity
Type | Complaint |
Activity Nr | 73758377 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260651 C02 |
Issuance Date | 1991-10-18 |
Abatement Due Date | 1991-10-24 |
Current Penalty | 750.0 |
Initial Penalty | 1500.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 03 |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260651 J02 |
Issuance Date | 1991-10-18 |
Abatement Due Date | 1991-10-24 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 03 |
Citation ID | 02001 |
Citaton Type | Repeat |
Standard Cited | 19260652 A01 |
Issuance Date | 1991-10-18 |
Abatement Due Date | 1991-10-24 |
Current Penalty | 1500.0 |
Initial Penalty | 3000.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 03 |