Search icon

FS NEWPORT MASONRY AND TILE LLC

Company Details

Name: FS NEWPORT MASONRY AND TILE LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Revoked Entity
Date of Organization in Rhode Island: 22 Apr 2011 (14 years ago)
Date of Dissolution: 30 Dec 2015 (9 years ago)
Date of Status Change: 30 Dec 2015 (9 years ago)
Identification Number: 000652134
ZIP code: 02840
County: Newport County
Principal Address: 174 BELLEVUE AVENUE SUITE 200A, NEWPORT, RI, 02840, USA
Purpose: MASONRY

Agent

Name Role Address
FRANCISCO SANTOS Agent 128A LAKE ERIE STREET, MIDDLETOWN, RI, 02842, USA

Manager

Name Role Address
FRANCISCO SANTOS Manager 72 WEST MAIN ROAD APT 3 MIDDLETOWN, RI 02842 USA

Filings

Number Name File Date
201589856150 Revocation Certificate For Failure to Maintain a Registered Office 2015-12-30
201581579840 Revocation Notice For Failure to Maintain a Registered Office 2015-10-05
201581253290 Registered Office Not Maintained 2015-09-25
201557872890 Annual Report 2015-03-20
201556349320 Revocation Notice For Failure to File An Annual Report 2015-03-04
201447124380 Statement of Change of Registered/Resident Agent 2014-10-03
201446911710 Miscellaneous Filing (No Fee) 2014-09-29
201446210570 Revocation Notice For Failure to Maintain a Registered Office 2014-09-18
201446199370 Registered Office Not Maintained 2014-09-02
201332129960 Annual Report 2013-12-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340788991 0112300 2015-07-21 PRAIRIE AVENUE, NEWPORT, RI, 02840
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-07-21
Emphasis L: FALL, P: FALL
Case Closed 2018-09-12

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2015-09-23
Current Penalty 2000.0
Initial Penalty 2800.0
Final Order 2015-10-13
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform): Worksite: The working platform on the fabricated framed scaffold was not fully planked between the uprights.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2015-09-23
Current Penalty 0.0
Initial Penalty 1600.0
Final Order 2015-10-13
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. Worksite: Fabricated framed scaffold did not bear on base plates and adequate mud sills.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2015-09-23
Current Penalty 0.0
Initial Penalty 1600.0
Final Order 2015-10-13
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: Worksite: Fabricated framed scaffold used by the employees was not inspected prior to use.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2015-09-23
Current Penalty 0.0
Initial Penalty 1200.0
Final Order 2015-10-13
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable: (2): The correct procedures for dealing with electrical hazards and for erecting, maintaining, and disassembling the fall protection systems and falling object protection systems being used: Worksite: Employees were not trained in the proper setup or use of scaffolds, in that scaffolds were not fully planked when used by workers; the scaffolds were not erected on stable footings so as to preclude movement and shifting while accessed by workers.

Date of last update: 15 Oct 2024