Name: | DIVERSIFIED GLOBAL TECHNOLOGIES, LLC |
Jurisdiction: | Rhode Island |
Entity type: | Foreign Limited Liability Company |
Status: | Cancelled |
Date of Organization in Rhode Island: | 29 Dec 2010 (14 years ago) |
Date of Dissolution: | 03 Sep 2020 (5 years ago) |
Date of Status Change: | 03 Sep 2020 (5 years ago) |
Identification Number: | 000567049 |
ZIP code: | 02895 |
County: | Providence County |
Place of Formation: | DELAWARE |
Principal Address: | 128 SINGLETON STREET, WOONSOCKET, RI, 02895, USA |
Purpose: | MANUFACTURER AND DISTRIBUTOR OF COSMETIC ACCESSORIES, SKIN CARE, BATH ACCESSORIES AND FOOTWEAR ACCESSORIES |
Fictitious names: |
Diversified Distribution (trading name, 2010-12-29 - 2019-11-27) |
NAICS
326150 Urethane and Other Foam Product (except Polystyrene) ManufacturingThis industry comprises establishments primarily engaged in manufacturing plastics foam products (except polystyrene). Learn more at the U.S. Census Bureau
Name | Role | Address |
---|---|---|
MICHAEL F. SWEENEY, ESQ. | Agent | 321 SOUTH MAIN STREET 4TH FLOOR, PROVIDENCE, RI, 02903, USA |
Name | Role | Address |
---|---|---|
JANICE K. AJOOTIAN | MANAGER | 3 MAPLEWOOD DRIVE LINCOLN, RI 02865 USA |
WAYNE M CELIA | MANAGER | 242 PURDUE CT PARAMUS, NJ 07652 USA |
Number | Name | File Date |
---|---|---|
202051874450 | Certificate of Cancellation | 2020-09-03 |
201928248770 | Statement of Abandonment of Use of Fictitious Business Name | 2019-11-27 |
201928248680 | Annual Report | 2019-11-27 |
201901624360 | Statement of Change of Registered/Resident Agent Office | 2019-07-03 |
201879853870 | Annual Report | 2018-10-22 |
201753752590 | Annual Report | 2017-11-21 |
201611865600 | Annual Report | 2016-11-08 |
201586584830 | Annual Report | 2015-10-30 |
201450304380 | Annual Report | 2014-11-21 |
201331601250 | Annual Report | 2013-12-04 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344110200 | 0112300 | 2019-06-26 | 128 SINGLETON STREET, WOONSOCKET, RI, 02895 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1468899 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100219 E01 I |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-10-03 |
Current Penalty | 2652.0 |
Initial Penalty | 5304.0 |
Final Order | 2019-10-03 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m): (a) Main building of operations: On or about 6/26/2019, the employer did not ensure that a guarding device was provided to fully enclose horizontal belts on a casting line. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100219 F03 |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-09-13 |
Current Penalty | 2652.0 |
Initial Penalty | 5304.0 |
Final Order | 2019-10-03 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: (a) Main building of operations: On or about 6/26/2019, the employer did not ensure to enclose two sprocket wheels and a chain. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100219 I02 |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-10-03 |
Current Penalty | 2652.0 |
Initial Penalty | 5304.0 |
Final Order | 2019-10-03 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.219(i)(2): Revolving surfaces of shaft coupling(s) were not covered by a safety sleeve: (a) Main building of operations: On or about 6/26/2019, the employer did not ensure to cover a revolving surface of shaft couplings. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100178 L06 |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-10-03 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-10-03 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l). a) Main building of operations: on or about 6/26/2019, the employer did not provide certificates for training and evaluation for each forklift operator. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2019-06-26 |
Emphasis | L: R1Noise, L: EISAOF, L: EISAX50 |
Case Closed | 2020-01-17 |
Related Activity
Type | Complaint |
Activity Nr | 1468899 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100134 C01 |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-12-31 |
Current Penalty | 1989.0 |
Initial Penalty | 3978.0 |
Final Order | 2019-10-03 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Facility: When employees in the Batch Area were required to wear half-mask elastomeric respirators for protection, the employer did not develop and implement a written respiratory protection program with worksite specific procedures. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100134 E01 |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-12-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-10-03 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Facility: When employees working in the Batch Area were required to wear half-mask elastomeric respirators, the employer did not ensure that affected employees received a medical evaluation to determine the employee's ability to use respiratory protection. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19100134 F01 |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-12-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-10-03 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test: (a) Facility: When employees were required to wear half-mask elastomeric respirators during foam-making operations, the employer did not ensure that the users received an appropriate qualitative or quantitative fit test. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19101200 E01 |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-10-25 |
Current Penalty | 1989.0 |
Initial Penalty | 3978.0 |
Final Order | 2019-10-03 |
Nr Instances | 1 |
Nr Exposed | 44 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Facility: When using foam-making chemicals to manufacture foam applicators, the employer did not develop and implement a written hazard communication program describing how the requirements of 29 CFR 1910.1200(f), (g), and (h) will be met. |
Date of last update: 14 Oct 2024