Search icon

WESTCHESTER PROPERTIES REAL ESTATE GROUP, LLC

Company Details

Name: WESTCHESTER PROPERTIES REAL ESTATE GROUP, LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Revoked Entity
Date of Organization in Rhode Island: 27 May 2010 (15 years ago)
Date of Dissolution: 03 Jun 2021 (4 years ago)
Date of Status Change: 03 Jun 2021 (4 years ago)
Identification Number: 000541214
ZIP code: 02903
County: Providence County
Principal Address: P.O. BOX 5799, PROVIDENCE, RI, 02903, USA
Mailing Address: 93 ALDEN STREET, WARWICK, RI, 02889, USA
Purpose: TO ENGAGE RESIDENTIAL OR COMMERCIAL REAL ESTATE SALES AND BROKERAGE

Agent

Name Role Address
LEPIZZERA AND LAPROCINA COUNSELLORS AT LAW LTD Agent 117 METRO CENTER BOULEVARD SUITE 2001, WARWICK, RI, 02886, USA

Filings

Number Name File Date
202197418600 Revocation Certificate For Failure to File the Annual Report for the Year 2021-06-03
202194501170 Revocation Notice For Failure to File An Annual Report 2021-03-16
201930671140 Annual Report 2019-12-26
201882350580 Annual Report 2018-12-07
201753126120 Annual Report 2017-11-08
201628299720 Annual Report 2016-11-30
201698769600 Statement of Change of Registered/Resident Agent 2016-05-10
201587955620 Annual Report 2015-11-18
201450273730 Annual Report 2014-11-20
201330930450 Annual Report 2013-11-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338921893 0112300 2013-02-27 223 POWER ST, PROVIDENCE, RI, 02906
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2013-04-19
Emphasis L: FALL, N: LEAD
Case Closed 2017-01-04

Related Activity

Type Complaint
Activity Nr 806024
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260062 D02 V
Issuance Date 2013-04-29
Abatement Due Date 2013-06-12
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-06-10
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.62(d)(2)(v): Prior to the performance of an employee exposure assessment as required by paragraph (d) of this section, the employer did not provide to employees performing the tasks described in paragraphs (d)(2)(i)-(iv) of this section interim protection, including appropriate respiratory protection in accordance with paragraph (f) of this section: Worksite: The employer did not provide employees, involved in the removal of window structures with paint containing lead, with interim protective measures prior to conducting employee exposure assessments.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2013-04-29
Abatement Due Date 2013-05-01
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-06-10
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around the opening: Worksite: On or about 2/27/13, the employer did not protect employees from falling approximately 8 feet to the lower level through an opening in the loft flooring for the stairwell.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260501 B14
Issuance Date 2013-04-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-06-10
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening was less than 39 inches (1.0 M) above the walking/working surface, was not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system: Worksite: On or about 2/27/13, the employer did not protect employees from falling through open second floor window wall openings higher than 10' above the outside ground surface.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260502 B02
Issuance Date 2013-04-29
Abatement Due Date 2013-05-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-06-10
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high: Worksite: On or about 2/27/13, the employer did not ensure that the guardrail system protecting employees from the second floor opening for the stairway was provided with midrails or equivalent structures between the top rail and the floor.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260502 B03
Issuance Date 2013-04-29
Abatement Due Date 2013-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-06-10
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge: Worksite: On or about 2/27/13, the employer did not ensure that the guardrail system protecting employees from the second floor opening for the stairway was capable of withstanding a force of at least 200 pounds.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2013-04-29
Abatement Due Date 2013-05-07
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-06-10
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: Worksite: On or about 2/27/13: a) The enclosed stairway leading from the first floor level to the second floor level was not provided with a handrail. b) The stairway leading from the second floor level to the loft floor level was not provided with a stairrail system .

Date of last update: 14 Oct 2024

Sources: Rhode Island Department of State