Search icon

GREEN-TECH ASSETS, LLC

Company Details

Name: GREEN-TECH ASSETS, LLC
Jurisdiction: Rhode Island
Entity type: Foreign Limited Liability Company
Status: Activ
Date of Organization in Rhode Island: 04 Feb 2009 (16 years ago)
Identification Number: 000503147
Place of Formation: DELAWARE
Principal Address: P.O. BOX 138, BELFORD, NJ, 07718, USA
Purpose: TECHNOLOGY DISPOSITION SERVICES

Agent

Name Role Address
THOMAS R. NOEL, ESQ. Agent 203 SOUTH MAIN STREET SUITE 2, PROVIDENCE, RI, 02903, USA

Manager

Name Role Address
CHARLES SAHYOUN Manager 4 WHITE HOUSE WAY MONROE TOWNSHIP, NJ 08831 USA

Filings

Number Name File Date
202451592800 Annual Report 2024-04-19
202334032120 Annual Report 2023-04-26
202222811460 Annual Report 2022-09-14
202218849640 Revocation Notice For Failure to File An Annual Report 2022-06-22
202105511940 Annual Report 2021-11-30
202185929840 Annual Report 2021-01-12
201925765900 Annual Report 2019-10-29
201879858550 Annual Report 2018-10-22
201752997370 Annual Report 2017-11-05
201627890450 Annual Report 2016-11-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341547479 0112300 2016-06-14 30 MEETING ST, CUMBERLAND, RI, 02864
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2016-10-28
Emphasis L: FORKLIFT
Case Closed 2018-05-29

Related Activity

Type Inspection
Activity Nr 1092488
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19100136 A
Issuance Date 2016-11-03
Current Penalty 3000.0
Initial Penalty 5701.0
Final Order 2016-11-22
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.136(a): The employer did not ensure that each affected employee used protective footwear when working in areas where there was a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet were exposed to electrical hazards: a) Warehouse areas, workstations and client locations: On or about 6-14-16 the employer did not ensure that employees working with pallets and boxes of recycled electronics were using appropriate protective foot wear. Green Tech Assets, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.136(a), which was contained in OSHA inspection number 1092488, citation number 1, item number 3 b and was affirmed as a final order on 3/29/16, with respect to a workplace located at 30 Meeting St, Cumberland, RI 02864.
Citation ID 01002
Citaton Type Repeat
Standard Cited 19100303 B02
Issuance Date 2016-11-03
Current Penalty 3000.0
Initial Penalty 4276.0
Final Order 2016-11-22
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Backroom/CDK Area: On or about 6-14-16 the employer had not ensured that electrical equipment was being used in accordance with instructions included on the equipment listing, specifically an electrical extension cord was observed providing power to a power strip. Green Tech Assets, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 1092488, citation number 1, item number 5 and was affirmed as a final order on 3/29/16, with respect to a workplace located at 30 Meeting St, Cumberland, RI 02864.
Citation ID 01003
Citaton Type Repeat
Standard Cited 19100303 G01
Issuance Date 2016-11-03
Current Penalty 3000.0
Initial Penalty 4276.0
Final Order 2016-11-22
Nr Instances 5
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Throughout the warehouse areas: The employer had not ensured that electrical panels had sufficient access and working space provided. Green Tech Assets, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(g)(1), which was contained in OSHA inspection number 1092488, citation number 1, item number 6 and was affirmed as a final order on 3/29/16, with respect to a workplace located at 30 Meeting St, Cumberland, RI 02864.
340924885 0112300 2015-09-14 30 MEETING ST, CUMBERLAND, RI, 02864
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2016-02-25
Emphasis L: FORKLIFT
Case Closed 2018-03-12

Related Activity

Type Complaint
Activity Nr 1017658
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100036 D01
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 10
FTA Inspection NR 1154747
FTA Issuance Date 2016-11-03
FTA Current Penalty 7000.0
FTA Final Order Date 2016-11-22
Citation text line 29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) Workplace: On or about 9-14-15 the employer did not ensure that exit route doors were able to open without the use of keys, tools or special knowledge, specifically: 1. Exit door on west side of the CDK/Backroom 2. Exit door on north side of rear warehouse. 3. Exit door on the west side of the rear warehouse adjacent to the vertical baler.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100037 A03
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Workplace: On or about 9-14-15 the employer did not ensure that exit routes were kept free and unobstructed, specifically: 1. Routes leading to the exit door on north side of rear warehouse, 2. Routes leading to the exit door on the west side of the rear warehouse adjacent to the vertical baler.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100038 B
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review: a) Workplace: On or about 9-14-15 the employer did not establish a written emergency action plan.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100157 C04
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(c)(4): The employer shall assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use: a) Receiving and shipping warehouses: On or about 9-14-16 the employer had not ensured that portable fire extinguishers were maintained in a fully charged and operable condition.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100157 E03
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) Receiving and shipping areas of front warehouse: On or about 9-14-16 the employer had not completed an annual maintenance check of fire extinguishers.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100132 D01
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): a) Throughout the workplace: On or about 9/14/15 the employer did not conduct a workplace hazard assessment where employees were routinely exposed to hazards including exposure of the feet to crushing injuries when handling boxes and pallets of recycled electronic office equipment. Abatement Note: Once the PPE Hazard Assessment is completed you shall: 1) Certify that the hazard assessment has been performed through a written certification in accordance with 1910.132 (d)(2), 2) Provide training to affected employees in proper use of required PPE (1910.132 (f)(1)) Guidance on conducting and documenting a PPE Hazard Assessment can be found on OSHA's website at: http://www.osha.gov/SLTC/personalprotectiveequipment/
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100136 A
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.136(a): The employer did not ensure that each affected employee used protective footwear when working in areas where there was a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet were exposed to electrical hazards: a) Warehouse areas, workstations and client locations: On or about 9-14-15 the employer did not ensure that employees working with pallets and boxes of recycled electronics were using appropriate protective foot wear.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Baler Area of Rear Warehouse: On or about 9-14-15 the employer had not ensured that the gate interlock was operational when the Selco Products Inc. V5 HD LR vertical baler was in use.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100303 B02
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Workplace: On or about 9-14-15 the employer had not ensured that electrical equipment was being used in accordance with instructions included on the equipment listing, specifically: a. Front Warehouse: Power strips were used to power other power strips at various work stations. b. Front Warehouse: Electrical extension cords were powering various power strips. c. Backroom/CDK Area : Electrical extension cords were providing power to power strips.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100303 G01
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2016-03-29
Nr Instances 5
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Throughout the warehouse areas: The employer had not ensured that electrical panels had sufficient access and working space provided.
Citation ID 01007
Citaton Type Serious
Standard Cited 19100305 G02 II
Issuance Date 2016-03-04
Abatement Due Date 2016-04-07
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a) Receiving Warehouse: On or about 9/14/15, the electrical cord for a floor fan had been spliced to another cord leaving exposed covered and bare conductors.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19100022 B01
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard: a) Warehouse Areas: On or about 9-14-15 the employer had not kept the passage ways clear and in good repair as noted by the following conditions observed: 1. Warehouse floors were not maintained in good repair, 2. The warehouse employee bathroom floor was not maintained free of standing water, 3. Walkway floors had extension cords crossing on them. Green Tech Assets, LLC was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 838363, citation number 1, item number 1 and was affirmed as a final order on 2/26/13, with respect to a workplace located at 30 Meeting St Cumberland, RI 02864.
Citation ID 03001
Citaton Type Other
Standard Cited 19100141 A03 I
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 11
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed: a) Employee Restroom in Warehouse: On or about 9-14-15 the employer did not maintain the employee restroom in a sanitary manner.
Citation ID 03002
Citaton Type Other
Standard Cited 19100141 A05
Issuance Date 2016-03-04
Abatement Due Date 2016-04-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 11
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(a)(5): A continuing and effective extermination program was not instituted where rodents, insects, or other vermin were detected: a) Break room kitchen: On or about 9-14-15 the employer did not maintain an effective rodent extermination program.
338383631 0112300 2013-01-22 30 MEETING ST, CUMBERLAND, RI, 02864
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-01-28
Emphasis L: FORKLIFT
Case Closed 2013-06-10

Related Activity

Type Complaint
Activity Nr 753491
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100022 B01
Issuance Date 2013-02-06
Abatement Due Date 2013-03-01
Current Penalty 600.0
Initial Penalty 1200.0
Final Order 2013-02-27
Nr Instances 3
Nr Exposed 6
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. (a) Warehouse - first and second floors: The wooden floors of the aisles and passageways were not kept in good repair, on or about 1-22-13.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100022 D01
Issuance Date 2013-02-06
Abatement Due Date 2013-03-01
Current Penalty 600.0
Initial Penalty 1200.0
Final Order 2013-02-27
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. (a) Warehouse - first and second floors: The floor load bearing capacity was not conspicuously posted , on or about 1-22-13.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100023 D01 II
Issuance Date 2013-02-06
Abatement Due Date 2013-03-01
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2013-02-27
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(d)(1)(ii): Stairway(s) less than 44 inches wide having one side open, did not have at least one stair railing on the open side: (a) Stairway area: The stairway measuring 37 3/4 inches wide leading from the first to the second floor did not have at least one stair railing on the open side, on or about 1-22-13.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2013-02-06
Abatement Due Date 2013-03-01
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2013-02-27
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) Warehouse: On or about 1-22-13, the employer permitted employees who had not completed the training and evaluation required by paragraph (l) to operate powered industrial trucks.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100178 L06
Issuance Date 2013-02-06
Abatement Due Date 2013-03-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-02-27
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) Warehouse: The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l), on or about 1-22-13.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100178 M05 I
Issuance Date 2013-02-06
Abatement Due Date 2013-02-22
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2013-02-27
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(m)(5)(i): When a powered industrial truck is left unattended, load engaging means were not fully lowered, controls were not netralized, power was not shut off, and brakes set. (a) Warehouse - first floor: The parking brake of the Nissan 35 propane powered industrial truck, s/n CPJ01A18PV, was not set while the truck was unattended, on or about 1-22-13.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100305 B02 I
Issuance Date 2013-02-06
Abatement Due Date 2013-02-22
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2013-02-27
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (A) Testing area: The 4 x 4 inch steel junction box located on the wall did not have a cover approved for the purpose, exposing the live wires inside, on or about 1-22-13.

Date of last update: 14 Oct 2024

Sources: Rhode Island Department of State