Search icon

New Providence Properties, LLC

Company Details

Name: New Providence Properties, LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Revoked Entity
Date of Organization in Rhode Island: 22 Aug 2008 (17 years ago)
Date of Dissolution: 14 May 2014 (11 years ago)
Date of Status Change: 14 May 2014 (11 years ago)
Identification Number: 000485538
ZIP code: 02919
County: Providence County
Principal Address: 22 BEACON STREET, JOHNSTON, RI, 02919, USA
Purpose: REAL ESTATE

Agent

Name Role Address
BETH ARUDA Agent 1116 PARK AVENUE, CRANSTON, RI, 02910, USA

MANAGER

Name Role Address
CHRISTOPHER RANONE MANAGER 22 BEACON STREET JOHNSTON, RI 02919 USA

Filings

Number Name File Date
201438980870 Revocation Certificate For Failure to File the Annual Report for the Year 2014-05-14
201433263130 Revocation Notice For Failure to File An Annual Report 2014-01-17
201315098250 Annual Report 2013-04-10
201308161260 Revocation Notice For Failure to File An Annual Report 2013-01-09
201292841360 Annual Report 2012-05-16
201292369170 Revocation Notice For Failure to File An Annual Report 2012-05-07
201067879990 Annual Report 2010-10-04
201060831300 Annual Report 2010-03-24
201060831580 Statement of Change of Registered/Resident Agent 2010-03-24
201060478730 Revocation Notice For Failure to File An Annual Report 2010-03-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339107856 0112300 2013-06-05 25 STELLA STREET, PROVIDENCE, RI, 02909
Inspection Type Planned
Scope Partial
Safety/Health Health
Close Conference 2013-06-05
Emphasis L: FALL, P: FALL
Case Closed 2018-09-06

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2013-07-23
Abatement Due Date 2013-07-28
Current Penalty 2520.0
Initial Penalty 2520.0
Final Order 2013-08-21
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: Worksite: Employees removing rigid roofing tiles in excess of six (6) feet above ground level were not protected against falling by the use of personal fall arrest systems, safety nets, or equivalent protection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-07-23
Abatement Due Date 2013-07-26
Current Penalty 1440.0
Initial Penalty 1440.0
Final Order 2013-08-21
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: Worksite: A portable ladder, used for access to the roof of the building, did not have the side rails extended to at least the required three (3) feet above the upper landing to facilitate roof access.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B06
Issuance Date 2013-07-23
Abatement Due Date 2013-07-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-21
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(6): Ladders were not used only on stable and level surfaces, nor secured to prevent accidental displacement: Worksite: A portable ladder, used as employee access to the roof, was not used on a stable and level surface.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261101 E01
Issuance Date 2013-07-23
Abatement Due Date 2013-07-30
Current Penalty 2160.0
Initial Penalty 2160.0
Final Order 2013-08-21
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(e)(1): All Class I, II and III asbestos work was not conducted within regulated areas: Worksite: Where employees were abrasively removing rigid, asbestos-containing roofing tiles, the employer did not establish a Class II regulated area.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261101 E06
Issuance Date 2013-07-23
Abatement Due Date 2013-07-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-21
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(e)(6): The employer did not ensure that all asbestos work performed within regulated areas is supervised by a competent person, as defined in paragraph (b) of this section: Worksite: When asbestos roofing tile was removed in an abrasive manner, the employer did not ensure that all work was supervised by a competent person.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261101 F02 I
Issuance Date 2013-07-23
Abatement Due Date 2013-08-05
Current Penalty 2160.0
Initial Penalty 2160.0
Final Order 2013-08-21
Nr Instances 6
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(f)(2)(i): Each employer who has a workplace or work operation covered by this standard shall ensure that a "competent person" conducts an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation or workplace: Worksite: When employees were abrasively removing asbestos-containing roofing tiles, the employer did not ensure that a "Competent Person" conducted an exposure assessment before or at the initiation of the work to ascertain expected employee exposures.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261101 G08 II A
Issuance Date 2013-07-23
Abatement Due Date 2013-07-30
Current Penalty 2160.0
Initial Penalty 2160.0
Final Order 2013-08-21
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(g)(8)(ii)(A): Roofing material was not removed in an intact state to the extent feasible: Worksite: When employees were removing asbestos-containing roofing tiles the employer did not exsure that it was removed intact to the extent feasible.
Citation ID 01006
Citaton Type Serious
Standard Cited 19261101 G08 II F
Issuance Date 2013-07-23
Abatement Due Date 2013-07-26
Current Penalty 2160.0
Initial Penalty 2160.0
Final Order 2013-08-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(g)(8)(ii)(F): Upon being lowered, unwrapped material was not transferred to a closed receptacle in such manner so as to preclude the dispersion of dust: Worksite: When employees removed asbestos-containing roofing shingles, the employer did not ensure they were transferred to a closed receptacle to preclude the dispersion of dust.
Citation ID 01007A
Citaton Type Serious
Standard Cited 19261101 K02 I
Issuance Date 2013-07-23
Abatement Due Date 2013-07-26
Current Penalty 2160.0
Initial Penalty 2160.0
Final Order 2013-08-21
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(k)(2)(i): Before work subject to this standard is begun, building and facility owners di not determine the presence, location, and quantity of ACM and/or PACM at the work site pursuant to paragraph (k)(1) of this section: Worksite: Prior to the abrasive removal of roofing shingles, the building owner did not determine the presence, location, and quantity of asbestos contained in the shingles.
Citation ID 01007B
Citaton Type Serious
Standard Cited 19261101 K02 II B
Issuance Date 2013-07-23
Abatement Due Date 2013-07-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-21
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(k)(2)(ii)(B): Building and/or facility owners did not notify the following persons of the presence, location and quantity of ACM or PACM, at the work sites in their buildings and facilities: Worksite: Employees of the house owner who worked in and/or adjacent to areas containing Asbestos-Containing Material (ACM) were not informed of the presence, location and quantity of the material.
Citation ID 01008
Citaton Type Serious
Standard Cited 19261101 K09 I
Issuance Date 2013-07-23
Abatement Due Date 2013-08-24
Current Penalty 2160.0
Initial Penalty 2160.0
Final Order 2013-08-21
Nr Instances 6
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(k)(9)(i): The employer did not train each employee who is likely to be exposed in excess of a PEL, and each employee who performed Class I through IV asbestos operations, in accordance with the requirements of this section: Worksite: When employees were abrasively removing asbestos-containing roof tiles, the employer did not ensure that each employees who performed this Class II removal was trained in accordance with the requirements of this section.

Date of last update: 09 May 2025