Search icon

ASPEN AEROGELS RHODE ISLAND, LLC

Company Details

Name: ASPEN AEROGELS RHODE ISLAND, LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Activ
Date of Organization in Rhode Island: 16 May 2008 (17 years ago)
Identification Number: 000396094
Principal Address: 30 FORBES ROAD BUILDING B, NORTHBOROUGH, MA, 01532, USA
Purpose: MANUFACTURING

Industry & Business Activity

NAICS

541330 Engineering Services

This industry comprises establishments primarily engaged in applying physical laws and principles of engineering in the design, development, and utilization of machines, materials, instruments, structures, processes, and systems. The assignments undertaken by these establishments may involve any of the following activities: provision of advice, preparation of feasibility studies, preparation of preliminary and final plans and designs, provision of technical services during the construction or installation phase, inspection and evaluation of engineering projects, and related services. Learn more at the U.S. Census Bureau

Agent

Name Role Address
CT CORPORATION SYSTEM Agent 450 VETERANS MEMORIAL PARKWAY SUITE 7A, EAST PROVIDENCE, RI, 02914, USA

Filings

Number Name File Date
202450888120 Annual Report 2024-04-12
202343005320 Statement of Change of Registered/Resident Agent 2023-11-29
202329042730 Annual Report 2023-02-22
202220386050 Annual Report 2022-06-27
202219756550 Revocation Notice For Failure to File An Annual Report 2022-06-22
202104821950 Annual Report 2021-11-02
202055878300 Annual Report 2020-09-17
201920852650 Annual Report 2019-09-18
201880082690 Annual Report 2018-10-24
201750098790 Annual Report 2017-09-18

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347436859 0112300 2024-04-24 3 DEXTER ROAD, EAST PROVIDENCE, RI, 02914
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2024-04-24
Case Closed 2024-05-22

Related Activity

Type Referral
Activity Nr 2154831
Health Yes
346615362 0112300 2023-04-04 3 DEXTER ROAD, EAST PROVIDENCE, RI, 02914
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2023-06-14
Emphasis N: AMPUTATE
Case Closed 2023-11-14

Related Activity

Type Inspection
Activity Nr 1661111
Health Yes
Type Referral
Activity Nr 2016284
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100212 A01
Issuance Date 2023-08-22
Abatement Due Date 2023-10-06
Current Penalty 8000.0
Initial Penalty 11162.0
Final Order 2023-09-19
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Finishing Line, Unwind station: On or about 3/31/2023, the employer did not ensure that employees were protected from pinch-points on the Unwind station clamp.
346611114 0112300 2023-04-04 3 DEXTER ROAD, EAST PROVIDENCE, RI, 02914
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2023-04-04
Emphasis N: DUSTEXPL
Case Closed 2024-12-26

Related Activity

Type Inspection
Activity Nr 1661536
Health Yes
Type Referral
Activity Nr 2015707
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100022 A01
Issuance Date 2023-08-22
Abatement Due Date 2023-12-19
Current Penalty 15625.0
Initial Penalty 15625.0
Contest Date 2023-09-18
Final Order 2024-01-22
Nr Instances 1
Nr Exposed 100
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. Facility at 3 Dexter Road EAST PROVIDENCE, RI in the finishing area: a. On or about April 4, 2023, the employer did not ensure all places of employment, including but not limited to the finishing area, were kept clean in that, the employer allowed combustible dust to accumulate on the floors, equipment, ovens, duct work, electrical conduits and boxes .
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100134 A02
Issuance Date 2023-08-22
Abatement Due Date 2023-12-19
Current Penalty 15625.0
Initial Penalty 15625.0
Contest Date 2023-09-18
Final Order 2024-01-22
Nr Instances 1
Nr Exposed 100
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(a)(2): A respirator was not provided by the employer to each employee when such equipment was necessary to protect the health of the employee. Facility at 3 Dexter Road EAST PROVIDENCE, RI in the finishing area: a. On or about April 4, 2023, the employer did not provide respirators to employees that worked in the finishing area, for job tasks including, but not limited to, water jet operators, for protection against exposures to Particulates Not Otherwise Regulated (PNOR) for total dust. At a minimum, a N95 NIOSH-certified filtering facepiece respirator is necessary to protect employees from Particulates Not Otherwise Regulated (PNOR) for total dust.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19101000 A02
Issuance Date 2023-08-22
Abatement Due Date 2024-12-27
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2023-09-18
Final Order 2024-01-22
Nr Instances 3
Nr Exposed 100
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Particulates Not Otherwise Regulated (PNOR) for total dust listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 15 mg/m3. Facility at 3 Dexter Road in EAST PROVIDENCE, RI: a. On or about April 4, 2023, an employee (EE B) working in the finishing area at oven 4 rewind was exposed to an 8-hour TWA of Particulates Not Otherwise Regulated, Total Dust, of 17 mg/m3, in excess of the 8-hour TWA permissible exposure limit of 15 mg/m3. b. On or about April 4, 2023, an employee (EE C) working in the finishing area as a coater was exposed to an 8-hour TWA of Particulates Not Otherwise Regulated, Total Dust, of 30 mg/m3, in excess of the 8-hour TWA permissible exposure limit of 15 mg/m3. c. On or about April 4, 2023, an employee (EE E) working in the water jet area was exposed to an 8-hour TWA of Particulates Not Otherwise Regulated, Total Dust, of 17 mg/m3, in excess of the 8-hour TWA permissible exposure limit of 15 mg/m3.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19101000 A02
Issuance Date 2023-08-22
Abatement Due Date 2024-12-27
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2023-09-18
Final Order 2024-01-22
Nr Instances 1
Nr Exposed 100
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Particulates Not Otherwise Regulated (PNOR) for respirable dust listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 5 mg/m3. Facility at 3 Dexter Road in EAST PROVIDENCE, RI: a. On or about April 4, 2023, an employee (EE C) working in the finishing area as a coater was exposed to an 8-hour TWA of Particulates Not Otherwise Regulated, Respirable Dust, of 7.1 mg/m3, in excess of the 8-hour TWA permissible exposure limit of 5 mg/m3.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19101000 E
Issuance Date 2023-08-22
Abatement Due Date 2023-10-06
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2023-09-18
Final Order 2024-01-22
Nr Instances 4
Nr Exposed 100
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d). Facility at 3 Dexter Road in EAST PROVIDENCE, RI: a. On or about April 4, 2023, an employee (EE B) working in the finishing area at oven 4 rewind was exposed to an 8-hour TWA of Particulates Not Otherwise Regulated, Total Dust, of 17 mg/m3, in excess of the 8-hour TWA permissible exposure limit of 15 mg/m3 without adequate administrative or engineering controls. b. On or about April 4, 2023, an employee (EE C) working in the finishing area as a coater was exposed to an 8-hour TWA of Particulates Not Otherwise Regulated, Total Dust, of 30 mg/m3, in excess of the 8-hour TWA permissible exposure limit of 15 mg/m3 without adequate administrative or engineering controls. c. On or about April 4, 2023, an employee (EE E) working in the water jet area was exposed to an 8-hour TWA of Particulates Not Otherwise Regulated, Total Dust, of 17 mg/m3, in excess of the 8-hour TWA permissible exposure limit of 15 mg/m3 without adequate administrative or engineering controls. d. On or about April 4, 2023, an employee (EE C) working in the finishing area as a coater was exposed to an 8-hour TWA of Particulates Not Otherwise Regulated, Respirable Dust, of 7.1 mg/m3, in excess of the 8-hour TWA permissible exposure limit of 5 mg/m3 without adequate administrative or engineering controls.
Citation ID 02001
Citaton Type Serious
Standard Cited 19100134 G01 I A
Issuance Date 2023-08-22
Abatement Due Date 2023-12-19
Current Penalty 15625.0
Initial Penalty 31250.0
Contest Date 2023-09-18
Final Order 2024-01-22
Nr Instances 1
Nr Exposed 100
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function. Facility at 3 Dexter Road EAST PROVIDENCE, RI in the finishing area: a. On or about April 4, 2023, employees that worked in the finishing area, for job tasks including but not limited to coater operators, had facial hair and wore tight fitting N95 filtering facepiece respirators for protection against exposures to Particulates Not Otherwise Regulated (PNOR) for total dust and respirable dust. Personal breathing zone sampling was conducted on the coater operator (EE C) and was found to be overexposed to PNOR for total dust and respirable dust while wearing an N95 with a full beard. Aspen Aerogels Rhode Island, LLC was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.134(g)(1)(i)(A), which was contained in OSHA inspection number 1401667, citation number 1, item number 1 and was affirmed as a final order on 11-21-2019, with respect to a workplace located at 3 Dexter Road in EAST PROVIDENCE, RI 02914.
Citation ID 03001
Citaton Type Other
Standard Cited 19040041 A01
Issuance Date 2023-08-22
Current Penalty 1000.0
Initial Penalty 2232.0
Contest Date 2023-09-18
Final Order 2024-01-22
Nr Instances 1
Nr Exposed 296
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.41(a)(1) If your establishment had 250 or more employees at any time during the previous calendar year, and this part requires your establishment to keep records, then you must electronically submit information from the three recordkeeping forms that you keep under this part (OSHA Form 300A Summary of Work-Related Injuries and Illnesses, OSHA Form 300 Log of Work-Related Injuries and Illnesses, and OSHA Form 301 Injury and Illness Incident Report) to OSHA or OSHA's designee. You must submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the forms. Facility at 3 Dexter Road, EAST PROVIDENCE, RI 02914: a.) On or about April 4, 2023, the employer failed during calendar year 2022, to electronically submit information from their OSHA Form 300A or equivalent by 03/02/2023. The establishment employed about 296 employees during calendar year 2022 and is classified with NAICS 325998 - All Other Miscellaneous Chemical Product and Preparation Manufacturing.
344016670 0112300 2019-05-16 3 DEXTER ROAD, EAST PROVIDENCE, RI, 02914
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2019-05-16
Emphasis L: EISAOF
Case Closed 2019-11-21

Related Activity

Type Referral
Activity Nr 1453575
Health Yes
Type Complaint
Activity Nr 1483178
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100134 G01 I A
Issuance Date 2019-11-08
Current Penalty 5303.9
Initial Penalty 7577.0
Final Order 2019-11-21
Nr Instances 1
Nr Exposed 100
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a) Slitting Operation: On or about 9/26/19 respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function.
341126084 0112300 2015-12-16 3 DEXTER ROAD, EAST PROVIDENCE, RI, 02914
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2015-12-16
Case Closed 2016-01-12

Related Activity

Type Complaint
Activity Nr 1046221
Health Yes
340852367 0112300 2015-08-17 3 DEXTER ROAD, EAST PROVIDENCE, RI, 02914
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2015-08-17
Emphasis N: AMPUTATE
Case Closed 2015-12-15

Related Activity

Type Referral
Activity Nr 1010221
Safety Yes
340771526 0112300 2015-07-09 3 DEXTER ROAD, EAST PROVIDENCE, RI, 02914
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2015-09-01
Case Closed 2015-09-01

Related Activity

Type Complaint
Activity Nr 998405
Health Yes
339532830 0112300 2013-12-27 3 DEXTER RD, EAST PROVIDENCE, RI, 02914
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2014-04-14
Emphasis N: CHEMNEP
Case Closed 2014-06-02

Related Activity

Type Referral
Activity Nr 866657
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100119 F01 I B
Issuance Date 2014-04-30
Abatement Due Date 2014-06-13
Current Penalty 5000.0
Initial Penalty 6930.0
Final Order 2014-05-22
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.119(f)(1)(i)(B): The employer did not develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and did not address normal operations: (a) Tank Farm: The employer did not develop and implement an adequate written procedure that provided clear instructions for safely conducting tanker truck loading operations for the ethanol loading process, such as but not limited to, procedures for selecting tankers for loading, verifying adequate tanker capacity, making line connections and equipment operation, on-going monitoring of the loading process, and emergency shut-down procedures, on or about 12-19-13.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100119 G01 I
Issuance Date 2014-04-30
Abatement Due Date 2014-06-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-22
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.119(g)(1)(i): The employer did not train each employee in the operating procedures as specified in paragraph (f) of 29 CFR 1910.119: (a) Tank Farm: The employer did not adequately train each employee involved in tanker truck loading operations for the ethanol loading process in areas such as, but not limited to, procedures for selecting tankers for loading, verifying adequate tanker capacity, and on-going monitoring of the loading process, on or about 12-19-13.
Citation ID 01002
Citaton Type Other
Standard Cited 19100120 Q06 II
Issuance Date 2014-04-30
Abatement Due Date 2014-06-13
Current Penalty 0.0
Initial Penalty 3960.0
Final Order 2014-05-22
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.120(q)(6)(ii): First responders at the operations level did not receive at least eight hours of training or did not have sufficient experience to objectively demonstrate competency in the areas required by 29 CFR 1910.120(q)(6)(ii)(A) through (q)(6)(ii)(F) and/or the employer did not so certify: (a) Tank Farm: Emergency response personnel responding to an Ethanol spill in the Tank Farm on 12-19-13 did not all receive at least eight hours of training or did not have sufficient experience to objectively demonstrate competency in the areas required by 29 CFR 1910.120(q)(6)(ii)(A) through (q)(6)(ii)(F) and/or the employer did not so certify.
Citation ID 02001
Citaton Type Other
Standard Cited 19100119 D03 I C
Issuance Date 2014-04-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-22
Nr Instances 1
Nr Exposed 12
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.119(d)(3)(i)(C): Information pertaining to the equipment in the process did not include the electrical classification: (a) Solvent Prep area: The electrical classification diagram of the Solvent Prep area did not contain any reference to reactor R-2311, on or about 12-27-13.
339197287 0112300 2013-07-17 3 DEXTER ROAD, EAST PROVIDENCE, RI, 02914
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2013-11-21
Case Closed 2013-11-21

Related Activity

Type Referral
Activity Nr 831614
Health Yes

Date of last update: 12 Oct 2024