342299757
|
0112300
|
2017-05-01
|
20 NEWMAN AVENUE, RUMFORD, RI, 02916
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-05-01
|
Emphasis |
N: SILICA, L: SILICA, P: SILICA
|
Case Closed |
2017-07-11
|
Related Activity
Type |
Inspection |
Activity Nr |
1229017 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1229114 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1229007 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 I |
Issuance Date |
2017-05-12 |
Abatement Due Date |
2017-06-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-06-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (Construction Reference 1926.103) (a) Worksite On or about 5/1/2017, the employer did not provide the information under Appendix D to employees who were provided with N95 Dust Mask Respirators on a voluntary basis while working with cement and brick fascia. |
|
|
340788926
|
0112300
|
2015-07-16
|
77 HIGHLAND ROAD, EAST PROVIDENCE, RI, 02914
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-07-16
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2015-10-19
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2015-08-20 |
Current Penalty |
1000.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-10-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Worksite: Guardrails were not provided on the fabricated framed scaffold where employee was exposed to a 10 feet 3 in fall. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260452 C02 |
Issuance Date |
2015-08-20 |
Current Penalty |
1000.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-10-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. Worksite: The fabricated framed scaffold the employee was working on did not have all cross bracing in place. |
|
|
339825895
|
0112300
|
2014-06-20
|
1 MEOLLER PLACE, PAWTUCKET, RI, 02860
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-06-20
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2014-09-30
|
Related Activity
Type |
Complaint |
Activity Nr |
895874 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2014-07-11 |
Abatement Due Date |
2014-08-26 |
Current Penalty |
0.0 |
Initial Penalty |
6300.0 |
Final Order |
2014-08-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury. a. Jobsite; On or about June 20, 2014, the employer did not train the employees to recognize and avoid unsafe conditions of improperly assembled scaffolding. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 C01 |
Issuance Date |
2014-07-11 |
Abatement Due Date |
2014-08-26 |
Current Penalty |
3500.0 |
Initial Penalty |
6300.0 |
Final Order |
2014-08-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a. Jobsite: On or about June 20, 2014, employees were found working on scaffolding that exceeded the base to height ratio without being restrained from tipping by guying, tying, bracing, or equivalent means. |
|
Citation ID |
03001A |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2014-07-11 |
Abatement Due Date |
2014-08-26 |
Current Penalty |
0.0 |
Initial Penalty |
6300.0 |
Final Order |
2014-08-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a. Jobsite: Employees were allowed to work from scaffolding that was not inspected for visible defects by a competent person before each work shift . |
|
Citation ID |
03001B |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2014-07-11 |
Abatement Due Date |
2014-08-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-08-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a. Jobsite: Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection |
|
|
310153663
|
0112300
|
2006-10-27
|
16-22 CHAPEL VIEW BOULEVARD, CRANSTON, RI, 02920
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2006-10-27
|
Emphasis |
S: COMMERCIAL CONSTR, L: FALL, L: EISA, S: FALL FROM HEIGHT
|
Case Closed |
2007-01-22
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2006-11-17 |
Abatement Due Date |
2006-11-30 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
|