Search icon

Fernandes Masonry, Inc.

Company Details

Name: Fernandes Masonry, Inc.
Jurisdiction: Rhode Island
Entity type: Foreign Corporation
Status: Revoked Entity
Date of Organization in Rhode Island: 26 Mar 2008 (17 years ago)
Date of Dissolution: 17 Sep 2024 (7 months ago)
Date of Status Change: 17 Sep 2024 (7 months ago)
Identification Number: 000321835
Place of Formation: MASSACHUSETTS
Principal Address: 1031 PHILLIPS ROAD, NEW BEDFORD, MA, 02745, USA
Purpose: PERFORMING MASONRY INSTALLATION, SUCH AS BLOCK, BRICK AND STONE

Industry & Business Activity

NAICS

238140 Masonry Contractors

This industry comprises establishments primarily engaged in masonry work, stone setting, bricklaying, and other stone work. The work performed may include new work, additions, alterations, maintenance, and repairs. Learn more at the U.S. Census Bureau

Agent

Name Role Address
HELDER M. MEDEIROS Agent RESTIVO MONACELLI LLP 36 EXCHANGE TERRACE, PROVIDENCE, RI, 02903, USA

PRESIDENT

Name Role Address
VICTOR M FERNANDES PRESIDENT 66 SLADES FARM LANE DARTMOUTH, MA 02748 USA

TREASURER

Name Role Address
JULIAO FERNANDES TREASURER 1432 MAIN STREET ACUSHNET, MA 02743 USA

CLERK

Name Role Address
DAVID FERNANDES CLERK 47 MEDEIROS LN N DARTMOUTH, MA 02747 USA

Filings

Number Name File Date
202459546760 Revocation Certificate For Failure to File the Annual Report for the Year 2024-09-17
202457178530 Revocation Notice For Failure to File An Annual Report 2024-06-25
202330669780 Annual Report 2023-03-13
202208321950 Annual Report 2022-01-20
202184046070 Annual Report 2021-01-04
202048157720 Annual Report 2020-08-12
201915975690 Annual Report 2019-08-28
201907080160 Revocation Notice For Failure to File An Annual Report 2019-07-24
201857301810 Annual Report 2018-02-02
201857300750 Statement of Change of Registered/Resident Agent 2018-02-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342299757 0112300 2017-05-01 20 NEWMAN AVENUE, RUMFORD, RI, 02916
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2017-05-01
Emphasis N: SILICA, L: SILICA, P: SILICA
Case Closed 2017-07-11

Related Activity

Type Inspection
Activity Nr 1229017
Safety Yes
Type Inspection
Activity Nr 1229114
Safety Yes
Type Inspection
Activity Nr 1229007
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100134 C02 I
Issuance Date 2017-05-12
Abatement Due Date 2017-06-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-06-08
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (Construction Reference 1926.103) (a) Worksite On or about 5/1/2017, the employer did not provide the information under Appendix D to employees who were provided with N95 Dust Mask Respirators on a voluntary basis while working with cement and brick fascia.
340788926 0112300 2015-07-16 77 HIGHLAND ROAD, EAST PROVIDENCE, RI, 02914
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-07-16
Emphasis L: FALL, P: FALL
Case Closed 2015-10-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2015-08-20
Current Penalty 1000.0
Initial Penalty 4900.0
Final Order 2015-10-15
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Worksite: Guardrails were not provided on the fabricated framed scaffold where employee was exposed to a 10 feet 3 in fall.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2015-08-20
Current Penalty 1000.0
Initial Penalty 3500.0
Final Order 2015-10-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. Worksite: The fabricated framed scaffold the employee was working on did not have all cross bracing in place.
339825895 0112300 2014-06-20 1 MEOLLER PLACE, PAWTUCKET, RI, 02860
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-06-20
Emphasis L: FALL, P: FALL
Case Closed 2014-09-30

Related Activity

Type Complaint
Activity Nr 895874
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2014-07-11
Abatement Due Date 2014-08-26
Current Penalty 0.0
Initial Penalty 6300.0
Final Order 2014-08-19
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury. a. Jobsite; On or about June 20, 2014, the employer did not train the employees to recognize and avoid unsafe conditions of improperly assembled scaffolding.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C01
Issuance Date 2014-07-11
Abatement Due Date 2014-08-26
Current Penalty 3500.0
Initial Penalty 6300.0
Final Order 2014-08-19
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a. Jobsite: On or about June 20, 2014, employees were found working on scaffolding that exceeded the base to height ratio without being restrained from tipping by guying, tying, bracing, or equivalent means.
Citation ID 03001A
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2014-07-11
Abatement Due Date 2014-08-26
Current Penalty 0.0
Initial Penalty 6300.0
Final Order 2014-08-19
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a. Jobsite: Employees were allowed to work from scaffolding that was not inspected for visible defects by a competent person before each work shift .
Citation ID 03001B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2014-07-11
Abatement Due Date 2014-08-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-19
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a. Jobsite: Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection
310153663 0112300 2006-10-27 16-22 CHAPEL VIEW BOULEVARD, CRANSTON, RI, 02920
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2006-10-27
Emphasis S: COMMERCIAL CONSTR, L: FALL, L: EISA, S: FALL FROM HEIGHT
Case Closed 2007-01-22

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2006-11-17
Abatement Due Date 2006-11-30
Current Penalty 1000.0
Initial Penalty 2000.0
Nr Instances 1
Nr Exposed 2
Gravity 10