Search icon

RENAISSANCE CORNICE, LLC

Company Details

Name: RENAISSANCE CORNICE, LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Activ
Date of Organization in Rhode Island: 25 Jan 2008 (17 years ago)
Identification Number: 000304833
ZIP code: 02920
County: Providence County
Principal Address: 114 HAZELTON STREET, CRANSTON, RI, 02920, USA
Purpose: SHEET METALWORK, ROOFING, GUTTERS

Agent

Name Role Address
JONATHAN L. UCRAN CPA LLC Agent 36 SMITH AVE, GREENVILLE, RI, 02828, USA

Filings

Number Name File Date
202449163140 Annual Report 2024-03-22
202340736380 Statement of Change of Registered/Resident Agent Office 2023-09-05
202326610590 Annual Report 2023-01-25
202208650780 Annual Report 2022-01-26
202100570960 Annual Report 2021-08-31
202056668630 Annual Report 2020-09-21
201929759400 Annual Report 2019-12-11
201929759680 Statement of Change of Registered/Resident Agent 2019-12-11
201929759770 Annual Report 2019-12-11
201929759860 Annual Report 2019-12-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339008682 0112300 2013-04-03 269 MELROSE STREET, PROVIDENCE, RI, 02907
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-04-03
Emphasis L: FALL
Case Closed 2017-08-16

Related Activity

Type Inspection
Activity Nr 898788
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2013-07-25
Abatement Due Date 2013-07-29
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2013-08-08
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Jobsite, rooftop southwest side of structure: On or about 04/03/2013, employees were performing construction activities in close proximity to the unguarded edges of the rooftop and exposed to a fall of approximately 15 feet whereby they were not protected by a guardrail system, net systems, or personal fall arrest systems.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2013-07-25
Abatement Due Date 2013-09-09
Current Penalty 0.0
Initial Penalty 1200.0
Final Order 2013-08-08
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Establishment: On, or about, 04/03/2013 the employer did not establish a training program for each employee who might be exposed to fall hazards.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2013-07-25
Abatement Due Date 2013-07-29
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2013-08-08
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). Jobsite: On or about 04/03/2013 an employee was working from a 15 foot straight ladder whereby the angle between the horizontal distance from the top support to the foot of the ladder was greater than approximately one-quarter of the working length of the ladder.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2013-07-25
Abatement Due Date 2013-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-08
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: Jobsite: On or about 04/03/2013 employees were using the top step of the Husky fiberglass folding ladder to access the roof bracket scaffold on the cornice roof.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2013-07-25
Abatement Due Date 2013-09-09
Current Penalty 0.0
Initial Penalty 1200.0
Final Order 2013-08-08
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: Establishment: On or about 11/15/2012 the employer did not provide a training program for each employee using ladders and stairways.
310154059 0112300 2006-12-15 41 RIDGE ROAD, NEWPORT, RI, 02841
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2006-12-15
Emphasis S: FALL FROM HEIGHT, L: FALL
Case Closed 2007-05-21

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2007-02-02
Abatement Due Date 2007-02-14
Current Penalty 375.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 2
Gravity 03

Date of last update: 11 Oct 2024