Search icon

DE WORKSHOP LLC

Company Details

Name: DE WORKSHOP LLC
Jurisdiction: Rhode Island
Entity type: Domestic Limited Liability Company
Status: Revoked Entity
Date of Organization in Rhode Island: 28 Dec 2007 (17 years ago)
Date of Dissolution: 30 Jul 2018 (7 years ago)
Date of Status Change: 30 Jul 2018 (7 years ago)
Identification Number: 000294067
ZIP code: 02906
County: Providence County
Principal Address: 114 LORIMER AVENUE, PROVIDENCE, RI, 02906, USA
Purpose: BUILD ANTIQUE STYLE TABLES AND REPAIR ANTIQUE FURNITURE
Historical names: The Lorimer Workshop LLC

Agent

Name Role Address
DAVID ELLISON Agent 114 LORIMER AVENUE, PROVIDENCE, RI, 02906, USA

Events

Type Date Old Value New Value
Name Change 2016-11-01 The Lorimer Workshop LLC DE WORKSHOP LLC

Filings

Number Name File Date
201873305410 Revocation Certificate For Failure to File the Annual Report for the Year 2018-07-30
201865612230 Revocation Notice For Failure to File An Annual Report 2018-05-15
201627892120 Annual Report 2016-11-23
201611594780 Articles of Amendment 2016-11-01
201579532660 Annual Report 2015-09-17
201438177810 Annual Report 2014-04-14
201328879880 Annual Report 2013-09-28
201296190590 Annual Report 2012-08-17
201181779910 Annual Report 2011-09-01
201066945830 Annual Report 2010-09-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341644193 0112300 2016-07-26 610 MANTON AVENUE, PROVIDENCE, RI, 02909
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2016-07-26
Emphasis N: DUSTEXPL, L: EISAOF
Case Closed 2017-05-16

Related Activity

Type Complaint
Activity Nr 1114563
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100094 C02
Issuance Date 2016-07-29
Abatement Due Date 2017-02-15
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2016-08-10
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.94(c)(2): Spray booth(s) or spray room(s) were not used to enclose or confine spray finishing operations: (a) Worksite: On or about 7/26/2016, the employer did not provide a spray booth or spray room for spray finishing operations.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2016-07-29
Abatement Due Date 2017-02-15
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-08-10
Nr Instances 2
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Worksite: On or about 7/26/2016, employees were required to wear half mask air purifying respirators and dust mask respirators without a written respiratory protection program outlining worksite specific procedures.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100134 C01 II
Issuance Date 2016-07-29
Abatement Due Date 2017-02-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-10
Nr Instances 2
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1)(ii): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was required to use the respirator in the workplace: (a) Worksite: On or about 7/26/2016, employees were required to wear respirators for spray coating and woodworking operations before being medically evaluated for their ability to use a respirator.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100134 C01 III
Issuance Date 2016-07-29
Abatement Due Date 2017-02-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-10
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1)(iii): The written program did not contain fit test procedures for tight-fitting respirators: (a) Worksite: On or before 7/26/2016, the employer did not ensure that fit tests occurred for those employees required to wear tight-fitting respirators.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19100134 C01 VIII
Issuance Date 2016-07-29
Abatement Due Date 2017-02-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-10
Nr Instances 2
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1)(viii): The written program did not contain provisions for training of employees in the proper use of respirators, including putting on and removing them, any limitations on their use, and their maintenance: (a) Worksite: On or about 7/26/2016, the employer did not provide respiratory protection program training to employees required to wear respirators.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100212 B
Issuance Date 2016-07-29
Abatement Due Date 2017-02-15
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2016-08-10
Nr Instances 5
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machines designed for fixed locations were not securely anchored to prevent walking or moving: (a) Worksite: On or about 7/26/2016, the employer did not ensure that stationary equipment such as pedestal drill presses were secured to prevent walking and tipping.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100213 C01
Issuance Date 2016-07-29
Abatement Due Date 2017-02-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-10
Nr Instances 2
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(1): Circular hand-fed rip saws were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: (a) Worksite: On or about 7/26/2016, the employer did not ensure that the table rip saw blades in the woodworking area were guarded.
Citation ID 02001
Citaton Type Other
Standard Cited 19100132 D01
Issuance Date 2016-07-29
Abatement Due Date 2017-02-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-10
Nr Instances 1
Nr Exposed 7
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: (a) Worksite: On or about 7/26/2016, the employer did not perform a hazard assessment in the workplace, with certification, before requiring employees to use personal protective equipment.
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2016-07-29
Abatement Due Date 2017-02-15
Current Penalty 200.0
Initial Penalty 400.0
Final Order 2016-08-10
Nr Instances 1
Nr Exposed 7
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Worksite: On or about 7/26/2016, the employer did not provide a written hazard communication program to employees.

Date of last update: 11 Oct 2024