Search icon

Estrela Bakery, Inc.

Company Details

Name: Estrela Bakery, Inc.
Jurisdiction: Rhode Island
Entity type: Domestic Profit Corporation
Status: Revoked Entity
Date of Organization in Rhode Island: 24 Jan 2006 (19 years ago)
Date of Dissolution: 11 Mar 2015 (10 years ago)
Date of Status Change: 11 Mar 2015 (10 years ago)
Identification Number: 000153534
ZIP code: 02914
County: Providence County
Principal Address: C/O JOSE ESTRELA 192 CENTRAL AVENUE, EAST PROVIDENCE, RI, 02914, USA
Purpose: BAKERY

Agent

Name Role Address
JOSE M. ESTRELA Agent 1106 SOUTH BROADWAY, EAST PROVIDENCE, RI, 02914, USA

PRESIDENT

Name Role Address
JOSE ESTRELA PRESIDENT 192 CENTRAL AVENUE EAST PROVIDENCE, RI 02914 USA

Filings

Number Name File Date
201556954100 Revocation Certificate For Failure to Maintain a Registered Office 2015-03-11
201552638400 Revocation Notice For Failure to Maintain a Registered Office 2015-01-02
201552616570 Registered Office Not Maintained 2014-12-18
201436630470 Annual Report 2014-03-03
201313382450 Annual Report 2013-03-02
201290526250 Annual Report 2012-03-01
201177023830 Annual Report 2011-03-29
201072670490 Annual Report 2010-12-08
201072670580 Annual Report 2010-12-08
201072670670 Annual Report 2010-12-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339432833 0112300 2013-10-18 1106 SOUTH BROADWAY, EAST PROVIDENCE, RI, 02914
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2013-10-21
Emphasis N: AMPUTATE
Case Closed 2014-09-17

Related Activity

Type Referral
Activity Nr 856267
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2014-04-01
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-04-24
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Dough and Baking Room: The employer had not established a lockout/tagout program when the employees were performing servicing, cleaning and maintenance of bakery equipment such as, but not limited to, dough sheeter, dough mixers and ovens.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100263 C03
Issuance Date 2014-04-01
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-04-24
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.263(c)(3): Sprocket(s) and V-belt drive(s) of bakery machinery located within reach from platform(s) or passageway(s) or located within 8 feet 6 inches from the floor were not completely enclosed: (a) Dough Processing Area: On or about 10/19/2013, the chains and sprockets of the pizza dough sheeter were not provided with an enclosure.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100263 G03
Issuance Date 2014-04-01
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-04-24
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.263(g)(3): Stopping device(s) were not within easy reach of the operator(s) feeding the moulder(s) and the area where dough is taken away from the moulder(s): (a) Dough Processing Area: On or about 10/18/2013, the Dough Sheeter was not provided with a stop pull cord at both the feed and take-away area.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100305 B01 I
Issuance Date 2014-04-01
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-04-24
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: (a) Dough Processing Area: On or about 10/18/2013, the opening through which conductors entered the junction box of the motor powering the Dough Sheeter equipment was not closed, in that the flexible conduit and conductors were hanging out of the opening. (b) Dough Processing Area: On or about 10/18/2013, the opening where the cord of the cord and plug connection at the on/off switch of the Dough Sheeter equipment entered the box was not closed, in that the cord and conductors were hanging out of the opening.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100305 B01 II
Issuance Date 2014-04-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-24
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Dough Processing Area: The junction box powering the motor of the Dough Sheeter was missing a knockout leaving an unused opening.