Search icon

VEOLIA WATER NORTH AMERICA OPERATING SERVICES, LLC

Company Details

Name: VEOLIA WATER NORTH AMERICA OPERATING SERVICES, LLC
Jurisdiction: Rhode Island
Entity type: Foreign Limited Liability Company
Status: Activ
Date of Organization in Rhode Island: 02 Feb 2006 (19 years ago)
Identification Number: 000153428
Place of Formation: DELAWARE
Principal Address: 53 STATE STREET 14TH FLOOR, BOSTON, MA, 02109, USA
Mailing Address: PO BOX 5095, HAVERHILL, MA, 01835, USA
Purpose: WATER AND WASTEWATER TREATMENT

Industry & Business Activity

NAICS

221310 Water Supply and Irrigation Systems

This industry comprises establishments primarily engaged in operating water treatment plants and/or operating water supply systems. The water supply system may include pumping stations, aqueducts, and/or distribution mains. The water may be used for drinking, irrigation, or other uses. Learn more at the U.S. Census Bureau

Agent

Name Role Address
CT CORPORATION SYSTEM Agent 450 VETERANS MEMORIAL PARKWAY SUITE 7A, EAST PROVIDENCE, RI, 02914, USA

MANAGER

Name Role Address
DENIS CHESSERON MANAGER 53 STATE STREET, 14TH FLOOR BOSTON, MA 02109 USA
DANIEL MAHONEY MANAGER 53 STATE STREET, 14TH FLOOR BOSTON, MA 02109 USA
BRIAN J CLARKE MANAGER 53 STATE STREET, 14TH FLOOR BOSTON, MA 02109 USA

Filings

Number Name File Date
202452808540 Annual Report 2024-04-26
202334574080 Annual Report 2023-04-28
202216397710 Annual Report 2022-04-29
202104303410 Annual Report 2021-10-29
202070129960 Annual Report 2020-10-30
201925832620 Annual Report 2019-10-29
201880545140 Annual Report 2018-10-31
201752715460 Annual Report 2017-11-01
201609053480 Annual Report 2016-09-20
201579695680 Annual Report 2015-09-18

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346701238 0112300 2023-05-15 140 PETTACONSETT AVENUE, CRANSTON, RI, 02920
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-05-15
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2023-08-28

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100138 A
Issuance Date 2023-07-06
Abatement Due Date 2023-08-21
Current Penalty 820.0
Initial Penalty 820.0
Final Order 2023-08-01
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees hands were exposed to hazardous conditions. (a) Worksite: On or about 5/15/2023, an employee actively engaged in maintenance of an air blower gauge was not utilizing appropriate hand protection, which exposed him to laceration hazards.
343556114 0112300 2018-10-24 140 PETTACONSETT AVENUE, CRANSTON, RI, 02920
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2018-10-24
Emphasis L: CRANE
Case Closed 2019-01-31

Related Activity

Type Inspection
Activity Nr 1356277
Safety Yes
338958705 0112300 2013-03-13 140 PETTACONSETT AVENUE, CRANSTON, RI, 02920
Inspection Type Planned
Scope Partial
Safety/Health Health
Close Conference 2013-08-30
Emphasis L: EISAOF, N: SSTARG11, P: SSTARG11
Case Closed 2013-10-31

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19100134 D01 III
Issuance Date 2013-09-09
Abatement Due Date 2013-12-09
Current Penalty 1000.0
Initial Penalty 3400.0
Final Order 2013-09-19
Nr Instances 1
Nr Exposed 42
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminants chemical state and physical form: Worksites including the Solids Handling Building: On or about 3/13/13 the employer had not provided reasonable estimates of employee exposures to respiratory hazards including, but not limited to respirable dust exposures when maintaining incineration and ash handling operations.
Citation ID 01001B
Citaton Type Other
Standard Cited 19100134 F02
Issuance Date 2013-09-09
Abatement Due Date 2013-10-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-19
Nr Instances 1
Nr Exposed 42
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested whenever a different respirator facepiece (size, style, model or make) was used: Worksite: Employees were provided with N-95 Particulate Respirators without being fit tested prior to use.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 G01 I A
Issuance Date 2013-09-09
Abatement Due Date 2013-10-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-19
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: Workplace: Several employees with facial hair did not remove facial hair prior to use of N-95 dust mask type respirators.
Citation ID 01002
Citaton Type Other
Standard Cited 19100151 C
Issuance Date 2013-09-09
Abatement Due Date 2013-10-23
Current Penalty 1000.0
Initial Penalty 3400.0
Final Order 2013-09-19
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: The Underground Utility Gallery between the Solids Handling Building and the Blower Building: On or about 4/2/13 the employer had not provided suitable facilities for quick drenching or flushing of the eyes and body when the lime slurry conveyance lines are serviced.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2013-09-09
Abatement Due Date 2013-09-17
Current Penalty 1500.0
Initial Penalty 2550.0
Final Order 2013-09-19
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. Maintenance Shop: The unused portion of the Dayton belt and disc sander was not adequately guarded exposing employees to the rotating parts.
Citation ID 01004A
Citaton Type Other
Standard Cited 19100304 G05
Issuance Date 2013-09-09
Abatement Due Date 2013-09-17
Current Penalty 1000.0
Initial Penalty 3400.0
Final Order 2013-09-19
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. Solids Handling Building, first floor near incinerator: The Dayton floor fan was not grounded in that its ground pin was missing.
Citation ID 01004B
Citaton Type Other
Standard Cited 19100305 G01 IV
Issuance Date 2013-09-09
Abatement Due Date 2013-09-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-19
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a): a. Maintenance Shop, Basement: Temporary wiring powering a sump pump was used in lieu of permanent wiring.
Citation ID 02001
Citaton Type Other
Standard Cited 19100037 B02
Issuance Date 2013-09-09
Abatement Due Date 2013-09-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-19
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": Control Room, Solids Handling Building: The exterior exit was not provided with an "EXIT" sign.
Citation ID 02002
Citaton Type Other
Standard Cited 19100095 D01
Issuance Date 2013-09-09
Abatement Due Date 2013-12-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-19
Nr Instances 1
Nr Exposed 42
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: Solids Handling Building: On or about 4/2/13 the employer had not monitored employee noise exposure for employees working adjacent to the sludge and ash processing equipment.
Citation ID 02003
Citaton Type Other
Standard Cited 19100120 Q01
Issuance Date 2013-09-09
Abatement Due Date 2013-12-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-19
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.120(q)(1): The employer did not develop and implement an emergency response plan to handle anticipated emergencies prior to commencement of emergency response operations: Dechlorination Building: On or about 3/13/13 the employers emergency action plan had not been updated to reflect the current practice of evacuation with no emergency response into the facility when alarms sound.
Citation ID 02004
Citaton Type Other
Standard Cited 19100147 C04 II
Issuance Date 2013-09-09
Abatement Due Date 2013-10-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-19
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section: a. Establishment: The employer's energy control procedure did not specifically state the techniques to be used to lock or tag out each type of machine.

Date of last update: 10 Oct 2024

Sources: Rhode Island Department of State