Name: | James Giguere Construction, Inc. |
Jurisdiction: | Rhode Island |
Entity type: | Domestic Profit Corporation |
Status: | Revoked Entity |
Date of Organization in Rhode Island: | 10 Jun 2004 (21 years ago) |
Date of Dissolution: | 12 Dec 2011 (13 years ago) |
Date of Status Change: | 12 Dec 2011 (13 years ago) |
Identification Number: | 000140796 |
ZIP code: | 02895 |
County: | Providence County |
Principal Address: | C/O JAMES GIGUERE 397 RATHBUN STREET, WOONSOCKET, RI, 02895, USA |
Purpose: | GENERAL CONSTRUCTION AND CONTRACTING |
Name | Role | Address |
---|---|---|
JAMES GIGUERE | Agent | 2060 BRONCOS HIGHWAY, GLENDALE, RI, 02826-, USA |
Name | Role | Address |
---|---|---|
JAMES GIGUERE | PRESIDENT | 2060 BRONCOS HIGHWAY GLENDALE, RI 02826- USA |
Name | Role | Address |
---|---|---|
CANDY JANE GIGUERE | VICE PRESIDENT | 2060 BRONCOS HWY GLENDALE, RI 02826 USA |
Number | Name | File Date |
---|---|---|
201186890430 | Revocation Certificate For Failure to File the Annual Report for the Year | 2011-12-12 |
201184004280 | Revocation Notice For Failure to File An Annual Report | 2011-10-11 |
201183909090 | Registered Office Not Maintained | 2011-09-22 |
201182493310 | Revocation Notice For Failure to File An Annual Report | 2011-09-13 |
201057445440 | Annual Report | 2010-01-27 |
200944712560 | Annual Report | 2009-03-31 |
200805110610 | Annual Report | 2008-01-03 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
338668049 | 0112300 | 2013-01-29 | 192 MIDDLE STREET, PAWTUCKET, RI, 02860 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 775791 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2013-03-14 |
Abatement Due Date | 2013-03-22 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-04-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. Jobsite: Employees working on the first floor and attic area, exposed to falls of more than 6 feet, were not provided with adequate fall protection systems. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2013-03-14 |
Abatement Due Date | 2013-03-22 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-04-09 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. Jobsite: A six foot ladder used to gain access to the attic area did not extend 3 feet above the landing. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19261053 B06 |
Issuance Date | 2013-03-14 |
Abatement Due Date | 2013-03-22 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-04-09 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(6): Ladders were used on surfaces which were not stable and level: a. Jobsite: A six foot ladder was not stable as it was placed on top of unsecured plywood in the attic area. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1987-09-30 |
Case Closed | 1987-11-09 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 Y04 III |
Issuance Date | 1987-10-14 |
Abatement Due Date | 1987-10-17 |
Current Penalty | 40.0 |
Initial Penalty | 40.0 |
Nr Instances | 2 |
Nr Exposed | 2 |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 Y05 |
Issuance Date | 1987-10-14 |
Abatement Due Date | 1987-10-17 |
Current Penalty | 40.0 |
Initial Penalty | 40.0 |
Nr Instances | 2 |
Nr Exposed | 2 |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 Y11 |
Issuance Date | 1987-10-14 |
Abatement Due Date | 1987-10-17 |
Current Penalty | 40.0 |
Initial Penalty | 40.0 |
Nr Instances | 2 |
Nr Exposed | 2 |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260450 A09 |
Issuance Date | 1987-10-14 |
Abatement Due Date | 1987-10-17 |
Nr Instances | 2 |
Nr Exposed | 2 |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19260450 A10 |
Issuance Date | 1987-10-14 |
Abatement Due Date | 1987-10-17 |
Nr Instances | 2 |
Nr Exposed | 2 |