Search icon

GIBSON HOMES INC.

Company Details

Name: GIBSON HOMES INC.
Jurisdiction: Rhode Island
Entity type: Domestic Profit Corporation
Status: Activ
Date of Organization in Rhode Island: 29 Apr 2003 (22 years ago)
Identification Number: 000131630
ZIP code: 02864
County: Providence County
Principal Address: 44 BIRCH ROAD, CUMBERLAND, RI, 02864, USA
Purpose: HOME CONSTRUCTION AND REMODEL

Industry & Business Activity

NAICS

236118 Residential Remodelers

This U.S. industry comprises establishments primarily responsible for the remodeling construction (including additions, alterations, reconstruction, maintenance, and repairs) of houses and other residential buildings, single-family and multifamily. Included in this industry are remodeling general contractors, for-sale remodelers, remodeling design-build firms, and remodeling project construction management firms. Learn more at the U.S. Census Bureau

Agent

Name Role Address
KEITH E. FAYAN, ESQ. Agent 640 GEO. WASH. HWY. BLDG. B STE. 103, LINCOLN, RI, 02865, USA

PRESIDENT

Name Role Address
SHAWN GIBSON PRESIDENT 44 BIRCH ROAD CUMBERLAND, RI 02864- USA

Filings

Number Name File Date
202447062490 Annual Report 2024-02-22
202331617050 Annual Report 2023-03-24
202326912270 Statement of Change of Registered/Resident Agent Office 2023-01-30
202213670050 Annual Report 2022-03-29
202197300590 Annual Report 2021-05-31
202196817170 Revocation Notice For Failure to File An Annual Report 2021-05-19
202036865710 Annual Report 2020-03-27
201987872860 Annual Report 2019-02-28
201857169500 Annual Report 2018-01-31
201735201830 Annual Report 2017-03-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346096332 0112300 2022-07-22 33 GOULD STREET, CUMBERLAND, RI, 02864
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2022-07-22
Emphasis L: FALL
Case Closed 2023-04-10

Related Activity

Type Referral
Activity Nr 1922931
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2022-12-02
Abatement Due Date 2023-01-20
Current Penalty 4351.0
Initial Penalty 4351.0
Contest Date 2023-01-17
Final Order 2023-04-05
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1):Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Worksite: On or about July 22, 2022, an employee was not protected from falling while working from a scaffold that was greater than 10 feet above a lower level.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 F15
Issuance Date 2022-12-02
Abatement Due Date 2023-01-20
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2023-01-17
Final Order 2023-04-05
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(15):Ladders were used on scaffolds to increase the working level height of employees: without satisfying the criteria of subparagraphs (i) - (iv) of this paragraph. a) Worksite: On or about July 22, 2022, a telescoping ladder was set up on the roof bracket scaffold with the legs anchored against the scaffold plank while lying flat on the 18-pitch roof.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2022-12-02
Current Penalty 0.0
Initial Penalty 4351.0
Contest Date 2023-01-17
Final Order 2023-04-05
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite: On or about July 22, 2022, employees were not protected from falling while working on a roof approximately 20 feet above the ground.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2022-12-02
Abatement Due Date 2022-12-28
Current Penalty 3108.0
Initial Penalty 3108.0
Contest Date 2023-01-17
Final Order 2023-04-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Worksite: On or about July 22, 2022, employees were not protected from falling while using a portable A frame step ladder, in the closed position, that did not extend at least three feet above the upper landing surface.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2022-12-02
Abatement Due Date 2022-12-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2023-01-17
Final Order 2023-04-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed: a) Worksite: On or about July 22, 2022, an employee was exposed to fall hazards while ascending and descending an A frame ladder step ladder, in the closed position, from a lower roof to access an upper roof. b) On or about July 22, 2022, an employee was exposed to fall hazards from using an unsecured telescoping ladder which was lying flat against the roofs surface to gain access to an upper-level area and for bracing feet while performing siding work.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19261053 B06
Issuance Date 2022-12-02
Abatement Due Date 2022-12-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2023-01-17
Final Order 2023-04-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: a) Worksite: On or about July 22, 2022, an employee was using a portable A Frame ladder positioned on a downward sloped roof that was not secured to prevent accidental displacement.
Citation ID 01003D
Citaton Type Serious
Standard Cited 19261053 B20
Issuance Date 2022-12-02
Abatement Due Date 2022-12-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2023-01-17
Final Order 2023-04-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(20): Employees were not facing the ladder when ascending or descending the ladder: a) Worksite: On or about July 22, 2022, an employee was exposed to fall hazards while descending a step ladder sideways.
Citation ID 01003E
Citaton Type Serious
Standard Cited 19261053 B21
Issuance Date 2022-12-02
Abatement Due Date 2022-12-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2023-01-17
Final Order 2023-04-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(21): Each employee was not grasping the ladder with at least one hand when progressing up and/or down the ladder: a) Worksite: On or about July 22, 2022, an employee was exposed to falling while descending an A framed ladder without at least one hand on the ladder.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2022-12-02
Abatement Due Date 2023-01-20
Current Penalty 0.0
Initial Penalty 349.0
Contest Date 2023-01-17
Final Order 2023-04-05
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) Worksite: On or about July 22, 2022, the employer did not create a written certification record verifying that employees received adequate fall protection training.

Date of last update: 10 Apr 2025

Sources: Rhode Island Department of State