347703977
|
0112300
|
2024-08-22
|
31 DELAINE STREET, PROVIDENCE, RI, 02909
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2024-08-22
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2024-08-26
|
|
343237947
|
0112300
|
2018-06-19
|
31 DELAINE ST., PROVIDENCE, RI, 02909
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-06-19
|
Case Closed |
2024-03-26
|
Related Activity
Type |
Referral |
Activity Nr |
1349887 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I |
Issuance Date |
2018-08-15 |
Abatement Due Date |
2019-09-27 |
Current Penalty |
3000.0 |
Initial Penalty |
9959.0 |
Contest Date |
2018-09-10 |
Final Order |
2019-06-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) In the drop area: On or about 6/19/2018, the employer did not provide adequate training to ensure the purpose and function of the energy control program was understood by all employees. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100147 C04 I |
Issuance Date |
2018-08-15 |
Abatement Due Date |
2019-09-27 |
Current Penalty |
4000.0 |
Initial Penalty |
18108.0 |
Contest Date |
2018-09-10 |
Final Order |
2019-06-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) In the drop area: On or about 6/19/2018, procedures were not developed and utilized to control hazardous energy while employees were engaged in servicing the drop hammer machine, in that the machine was in operation while servicing took place. Tercat Tool and Die Co. II, Inc. was previously cited for a violation of this occupational and health standard which was contained in OSHA inspection 949242 citation number 1, item 1 and was affirmed as a final order on 2/4/2014, with respect to the workplace located at 131 Delaine St. Providence, RI 02909. |
|
|
342229614
|
0112300
|
2017-03-30
|
31 DELAINE ST, PROVIDENCE, RI, 02909
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-06-02
|
Emphasis |
L: EISAOF, L: EISAX30, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2017-08-28
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2017-06-30 |
Current Penalty |
3549.0 |
Initial Penalty |
5070.0 |
Final Order |
2017-08-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by ingoing nip points and rotating parts: (a) Single Stroke Mechanical Power Press Area: The unused run and the ingoing nip point of the sanding belt on the vertical belt sanding machine was not provided with a guard to prevent accidental contact. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100217 C03 VIII C |
Issuance Date |
2017-06-30 |
Abatement Due Date |
2017-08-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-08-28 |
Nr Instances |
4 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(c)(3)(viii)(c): The safety distance (D(m)) between each two hand trip device and the point of operation was not greater than the distance determined by the following formula: D(m) = 63 inches/second X T(m); where: D(m) = minimum safety distance (inches); 63 inches/second=hand speed constant; and T(m) = the maximum time the press takes for the die closure after it has been tripped (seconds). (a) Single Stroke Press Department: The Press Rite, HAVIR Manufacturing, mechanical power press had two hand trip levers which were 16 and 15 inches away from the point of operation, where the safety distance was less than that of the above formula, which was determined to be 20 inches. (b) Single Stroke Press Department: Mechanical power press number 2 had two hand trip levers which were 5 and 6 inches away from the point of operation, where the safety distance was less than that of the above formula, which was determined to be 11.8 inches. (c) Single Stroke Press Department: The Standard Machinery Co. No. 3T, mechanical power press number 3, had two hand trip levers which were 5 and 5.5 inches away from the point of operation, where the safety distance was less than that of the above formula, which was determined to be 8.9 inches. (d) Single Stroke Press Department: The Standard Machinery Co. No. 3T, mechanical power press Number 4, had two hand trip levers which were 5 and 6 inches away from the point of operation, where the safety distance was less than that of the above formula, which was determined to be 8.9 inches. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040004 A |
Issuance Date |
2017-06-30 |
Abatement Due Date |
2017-07-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-08-28 |
Nr Instances |
1 |
Nr Exposed |
30 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent: (a) Establishment: On or about 03/30/2017, the employer did not record a recordable finger injury on the OSHA Form 300 or equivalent for calendar year 2017. |
|
|
339492423
|
0112300
|
2013-11-20
|
31 DELAINE ST, PROVIDENCE, RI, 02909
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-01-07
|
Emphasis |
L: EISAOF, L: EISAX30, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2014-05-15
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2014-01-16 |
Abatement Due Date |
2014-02-10 |
Current Penalty |
1120.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-02-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Facility: Energy control procedures, such as but not limited to the placing of locks and tags on equipment being serviced, were not being utilized by facility maintenance personnel while servicing machinery and equipment covered by this section, on or about 11-20-13. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100217 C01 I |
Issuance Date |
2014-01-16 |
Abatement Due Date |
2014-02-10 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-02-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es): (a) Press area: Mechanical Power Press #13 was not guarded by any point of operation guards or properly applied point of operation devices, on or about 11-20-13. (b) Press area: Mechanical Power Press #71 was not guarded by any point of operation guards or properly applied point of operation devices, on or about 11-20-13. |
|
|