Search icon

Coletta Contracting Company, Inc.

Company Details

Name: Coletta Contracting Company, Inc.
Jurisdiction: Rhode Island
Entity type: Domestic Profit Corporation
Status: Activ
Date of Organization in Rhode Island: 28 Dec 2000 (24 years ago)
Identification Number: 000116025
ZIP code: 02885
County: Bristol County
Principal Address: 44 HOLLISTER ROAD, SEEKONK, MA, 02885, USA
Purpose: GENERAL CONTRACTING, SUB-CONTRACTING, GENERAL CONSTRUCTION

Industry & Business Activity

NAICS

236220 Commercial and Institutional Building Construction

This industry comprises establishments primarily responsible for the construction (including new work, additions, alterations, maintenance, and repairs) of commercial and institutional buildings and related structures, such as stadiums, grain elevators, and indoor swimming facilities. This industry includes establishments responsible for the on-site assembly of modular or prefabricated commercial and institutional buildings. Included in this industry are commercial and institutional building general contractors, commercial and institutional building for-sale builders, commercial and institutional building design-build firms, and commercial and institutional building project construction management firms. Learn more at the U.S. Census Bureau

PRESIDENT

Name Role Address
ROBERT J COLETTA PRESIDENT 85 CHRISTOPHER STREET PROVIDNEC, RI 02904 USA

Agent

Name Role Address
JUSTIN J COLETTA Agent 65 TRUAMN AVE, WARREN, RI, 02885, USA

TREASURER

Name Role Address
ROBERT J COLETTA TREASURER 85 CHRISTPHER STREET PROVIDENCE, RI 02904 USA

SECRETARY

Name Role Address
JUSTIN J. COLETTA SECRETARY 65 TRUMAN AVENUE WARREN, RI 02885 USA

VICE PRESIDENT

Name Role Address
JUSTIN J. COLETTA VICE PRESIDENT 65 TRUMAN AVENUE WARREN, RI 02885 USA

Filings

Number Name File Date
202454871830 Annual Report 2024-05-24
202335710540 Annual Report 2023-05-16
202215488400 Annual Report 2022-04-15
202195037380 Annual Report 2021-03-29
202035485810 Annual Report 2020-02-27
201989398980 Annual Report 2019-03-27
201860404290 Annual Report 2018-03-16
201737541420 Annual Report 2017-03-06
201694905480 Annual Report 2016-03-22
201555934950 Annual Report 2015-02-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347513327 0112300 2024-05-30 470 METACOM AVENUE, BRISTOL, RI, 02809
Inspection Type Planned
Scope NoInspection
Safety/Health Safety
Close Conference 2024-05-30
Emphasis N: CTARGET, P: CTARGET
Case Closed 2024-06-03
347072696 0112300 2023-11-01 600 MOUNT PLEASANT AVENUE, PROVIDENCE, RI, 02908
Inspection Type Planned
Scope Partial
Safety/Health Health
Close Conference 2023-11-01
Emphasis N: CTARGET, P: CTARGET
Case Closed 2023-11-13
342329851 0112300 2017-05-16 26 SHIP STREET, PROVIDENCE, RI, 02903
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2017-05-16
Emphasis L: FALL, L: EISAX30, L: EISAOF
Case Closed 2017-06-22

Related Activity

Type Inspection
Activity Nr 1232952
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2017-05-30
Current Penalty 1616.0
Initial Penalty 2309.0
Final Order 2017-06-13
Nr Instances 1
Nr Exposed 9
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Worksite - Roof Hatch: On or about 5/16/2017, employees were not protected from falling while using a ladder that did not extend at least three feet above the upper landing surface.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2017-05-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-06-13
Nr Instances 1
Nr Exposed 9
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) Worksite - Roof Hatch: On or about 5/16/2017, the two sections of a twenty-four foot extension ladder were split apart, and a single section was used to gain access to the roof level.

Date of last update: 10 Apr 2025