OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340405752 0112300 2015-02-11 1151 POINT JUDITH ROAD, NARRAGANSETT, RI, 02882
Inspection Type Planned
Scope NoInspection
Safety/Health Safety
Close Conference 2015-02-11
Emphasis L: FALL, P: FALL
Case Closed 2015-03-05
337830020 0112300 2012-12-13 ROMANO VINEYARD DR, NORTH KINGSTOWN, RI, 02852
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-12-13
Emphasis L: FALL
Case Closed 2013-08-20

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2012-12-27
Abatement Due Date 2013-01-14
Current Penalty 1000.0
Initial Penalty 1760.0
Final Order 2013-01-24
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) Jobsite: The relocatable power tap powering jobsite equipment was not installed in accordance with instructions from the manufacturer and included in the listing and labeling, UL XBYS, in that it was being used at a construction site, which is prohibited under the listing instruction, for a jobsite located in North Kingstown RI on or about 12-13-12.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260416 E01
Issuance Date 2012-12-27
Abatement Due Date 2013-01-14
Current Penalty 0.0
Initial Penalty 1760.0
Final Order 2013-01-24
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Jobsite: A cord with frayed outer insulation was in use powering an electric radio, for a jobsite located in North Kingstown RI on or about 12-13-12.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2012-12-27
Abatement Due Date 2013-01-14
Current Penalty 2000.0
Initial Penalty 3080.0
Final Order 2013-01-24
Nr Instances 2
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: (a) Jobsite: Employees performing roof sheathing, at a height of approximately 11 feet from the ground, were not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems, for a jobsite located in North Kingstown RI on or about 12-13-12.
314916024 0112300 2011-01-26 180 BOSTON NECK ROAD, NARRAGANSETT, RI, 02882
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2011-01-26
Emphasis S: RESIDENTIAL CONSTR, L: FALL, S: FALL FROM HEIGHT
Case Closed 2011-06-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2011-02-09
Abatement Due Date 2011-02-14
Current Penalty 1890.0
Initial Penalty 3780.0
Nr Instances 1
Nr Exposed 1
Gravity 10

Date of last update: 09 Apr 2025