Search icon

S.A. Davol Co., Inc.

Company Details

Name: S.A. Davol Co., Inc.
Jurisdiction: Rhode Island
Entity type: Domestic Profit Corporation
Status: Activ
Date of Organization in Rhode Island: 22 Apr 1994 (31 years ago)
Identification Number: 000076601
ZIP code: 02878
County: Newport County
Principal Address: 453 STONE CHURCH RD, TIVERTON, RI, 02878, USA
Purpose: CONSTRUCT, BUILD, REFURBISH & REPAIR RESIDENTIAL/COMMERCIAL REAL ESTATE

Industry & Business Activity

NAICS

561790 Other Services to Buildings and Dwellings

This industry comprises establishments primarily engaged in providing services to buildings and dwellings (except exterminating and pest control; janitorial; landscaping care and maintenance; and carpet and upholstery cleaning). Learn more at the U.S. Census Bureau

Agent

Name Role Address
STEVEN A. DAVOL Agent 453 STONE CHURCH ROAD, TIVERTON, RI, 02878, USA

PRESIDENT

Name Role Address
STEVEN A DAVOL PRESIDENT 453 STONE CHURCH ROAD TIVERTON, RI 02878 USA

VICE PRESIDENT

Name Role Address
NANCY K. DAVOL VICE PRESIDENT 453 STONE CHURCH ROAD TIVERTON, RI 02878 USA

Filings

Number Name File Date
202445614240 Annual Report 2024-02-05
202331130450 Annual Report 2023-03-20
202209740570 Annual Report 2022-02-08
202184195660 Annual Report 2021-01-05
201930353910 Annual Report 2019-12-18
201983948910 Annual Report 2019-01-08
201755173320 Annual Report 2017-12-19
201729985900 Annual Report 2017-01-11
201602179600 Annual Report 2016-07-18
201601398390 Revocation Notice For Failure to File An Annual Report 2016-07-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341559664 0112300 2016-06-17 36 OCHRE POINT AVENUE, NEWPORT, RI, 02840
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2016-06-17
Emphasis L: FALL
Case Closed 2016-10-17

Related Activity

Type Referral
Activity Nr 1103416
Safety Yes
Type Inspection
Activity Nr 1171909
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2016-07-25
Abatement Due Date 2016-08-03
Current Penalty 2000.0
Initial Penalty 2800.0
Final Order 2016-08-10
Nr Instances 11
Nr Exposed 5
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: (a) Worksite - Roof: On or about 6/17/2016, employees were not protected from falling approximately thirteen feet to the lower level while working in close proximity to unguarded skylights.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260502 H02
Issuance Date 2016-07-25
Abatement Due Date 2016-08-03
Current Penalty 2000.0
Initial Penalty 2800.0
Final Order 2016-08-10
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(h)(2): Mechanical equipment was used and stored in an area where a safety monitoring system was used to protect employees who were involved in roofing operations: (a) Worksite - Roof: On or about 6/17/2016, employees used and stored mechanical equipment to strip and cut material from a multi-story building with a low sloped roof, where a safety monitor system was used to protect these employees from fall hazards.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260502 I03
Issuance Date 2016-07-25
Abatement Due Date 2016-08-03
Current Penalty 2000.0
Initial Penalty 2800.0
Final Order 2016-08-10
Nr Instances 4
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: (a) Worksite - Roof: On or about 6/17/2016, employees were exposed to the hazard of falling into roof holes which were not protected by a secured cover.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260502 I04
Issuance Date 2016-07-25
Abatement Due Date 2016-08-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-10
Nr Instances 4
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: (a) Worksite - Roof: On or about 6/17/2016, the employer did not ensure that roof hole covers were either color coded or marked as "Hole or "Cover" to warn employees of the hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260502 H01 I
Issuance Date 2016-07-25
Abatement Due Date 2016-08-03
Current Penalty 0.0
Initial Penalty 400.0
Final Order 2016-08-10
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(h)(1)(i): The safety monitor was not competent to recognize fall hazards: (a) Worksite - Roof: On or about 6/17/2016, the employer did not ensure that the assigned safety monitor had the necessary training and understanding to competently perform the duties of the job.

Date of last update: 08 Apr 2025