Search icon

NEW PENN MOTOR EXPRESS, INC.

Company Details

Name: NEW PENN MOTOR EXPRESS, INC.
Jurisdiction: Rhode Island
Entity type: Foreign Corporation
Status: Conversion
Date of Organization in Rhode Island: 06 Mar 1992 (33 years ago)
Date of Dissolution: 15 Aug 2016 (9 years ago)
Date of Status Change: 15 Aug 2016 (9 years ago)
Identification Number: 000067367
Place of Formation: PENNSYLVANIA
Principal Address: 10990 ROE AVENUE ATTN: TAX DEPARTMENT, OVERLAND PARK, KS, 66211-1213, USA
Purpose: COMMON CARRIER OF GENERAL FREIGHT.
Fictitious names: NPME, Inc. (trading name, 1992-03-06 - )

Agent

Name Role Address
CT CORPORATION SYSTEM Agent 450 VETERANS MEMORIAL PARKWAY SUITE 7A, EAST PROVIDENCE, RI, 02914, USA

PRESIDENT

Name Role Address
DONALD D. FOUST PRESIDENT 10990 ROE AVENUE, ATTN: TAX DEPARTMENT OVERLAND PARK, KS 66211 USA

Events

Type Date Old Value New Value
Conversion 2016-08-15 NEW PENN MOTOR EXPRESS, INC. NEW PENN MOTOR EXPRESS LLC on 08-15-2016

Filings

Number Name File Date
201691617890 Annual Report 2016-02-01
201556079290 Annual Report 2015-03-02
201436133520 Annual Report 2014-02-24
201323894130 Statement of Change of Registered/Resident Agent Office 2013-06-17
201311623780 Annual Report 2013-02-14
201311988230 Statement of Change of Registered/Resident Agent Office 2013-02-12
201289561750 Annual Report 2012-02-13
201178675560 Statement of Change of Registered/Resident Agent Office 2011-05-02
201174635450 Annual Report 2011-02-08
201059825790 Annual Report 2010-03-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341291979 0112300 2016-03-02 2110 PLAINFIELD PIKE, CRANSTON, RI, 02910
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-03-02
Emphasis L: EISAOF, L: FORKLIFT, N: SSTARG14, P: SSTARG14
Case Closed 2016-04-05

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100184 C01
Issuance Date 2016-03-07
Current Penalty 1683.0
Initial Penalty 3366.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.184(c)(1): Slings that were damaged or defective were used: (a) Worksite - Warehouse: On or about 3/2/2016, the employer did not ensure that a damaged nine foot long one inch wide web sling used to hoist and pull freight was taken out of service.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100334 A02 I
Issuance Date 2016-03-07
Current Penalty 2475.0
Initial Penalty 4950.0
Final Order 2016-03-29
Nr Instances 4
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): (a) Worksite - Outdoor tractor parking area: On or about 3/2/2016, the employer did not ensure that power extension cords were properly inspected before use.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100334 A02 II
Issuance Date 2016-03-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-29
Nr Instances 4
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: (a) Worksite - Outdoor tractor parking area: On or about 3/2/2016, the employer did not ensure that damaged power extension cords used to plug in engine block heaters were taken out of service.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19100305 J02 VI
Issuance Date 2016-03-07
Abatement Due Date 2016-04-20
Current Penalty 0.0
Initial Penalty 4950.0
Final Order 2016-03-29
Nr Instances 4
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(j)(2)(vi): A receptacle installed in a wet location where the product intended to be plugged into it was not to be attended while in use (for example, sprinkler system controllers, landscape lighting, and holiday lights) did not have an enclosure that was weatherproof with the attachment plug cap inserted or removed: (a) Worksite - Outdoor tractor parking area: On or about 3/2/2016, the employer did not ensure that outdoor electrical outlets used to plug in engine block heaters had their weather protecting covers in the closed position.
314921248 0112300 2012-03-06 2110 PLAINFIELD PIKE, CRANSTON, RI, 02910
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-03-29
Emphasis S: POWERED IND VEHICLE, N: SSTARG11, L: FORKLIFT
Case Closed 2012-06-05

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19100178 A04
Issuance Date 2012-04-09
Abatement Due Date 2012-06-01
Current Penalty 1000.0
Initial Penalty 5500.0
Nr Instances 1
Nr Exposed 15
Gravity 05
Citation ID 01001B
Citaton Type Other
Standard Cited 19100178 A06
Issuance Date 2012-04-09
Abatement Due Date 2012-06-01
Nr Instances 2
Nr Exposed 15
Gravity 05
Citation ID 01002
Citaton Type Other
Standard Cited 19100178 M05 I
Issuance Date 2012-04-09
Abatement Due Date 2012-04-26
Current Penalty 1000.0
Initial Penalty 5500.0
Nr Instances 3
Nr Exposed 15
Gravity 05
312346463 0112300 2010-06-29 2110 PLAINFIELD PIKE, CRANSTON, RI, 02920
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2010-07-01
Emphasis S: POWERED IND VEHICLE, S: FALL FROM HEIGHT, L: FALL, L: FORKLIFT
Case Closed 2010-12-03

Related Activity

Type Complaint
Activity Nr 207700279
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2010-11-04
Abatement Due Date 2010-11-30
Current Penalty 2975.0
Initial Penalty 2975.0
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 05
Hazard CRUSHING
Citation ID 01002
Citaton Type Serious
Standard Cited 19100022 B02
Issuance Date 2010-11-04
Abatement Due Date 2010-11-30
Initial Penalty 1700.0
Nr Instances 1
Nr Exposed 15
Related Event Code (REC) Complaint
Gravity 05
Citation ID 01003
Citaton Type Serious
Standard Cited 19100138 A
Issuance Date 2010-11-04
Abatement Due Date 2010-11-30
Initial Penalty 2125.0
Nr Instances 1
Nr Exposed 10
Gravity 05
Citation ID 01004
Citaton Type Other
Standard Cited 19100178 Q07
Issuance Date 2010-11-04
Abatement Due Date 2010-11-30
Initial Penalty 2975.0
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 05
100777168 0112300 1988-12-07 280 HARBORSIDE PARK BLVD., CRANSTON, RI, 02910
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 1988-12-07
Case Closed 1989-03-10

Related Activity

Type Complaint
Activity Nr 72141849
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19040002 A
Issuance Date 1989-01-26
Abatement Due Date 1989-02-01
Nr Instances 1
Nr Exposed 45
Gravity 00
Citation ID 01002A
Citaton Type Other
Standard Cited 19040005 B
Issuance Date 1989-01-26
Abatement Due Date 1989-02-01
Nr Instances 1
Nr Exposed 45
Gravity 00
Citation ID 01002B
Citaton Type Other
Standard Cited 19040005 C
Issuance Date 1989-01-26
Abatement Due Date 1989-02-01
Nr Instances 1
Nr Exposed 45
Gravity 00
Citation ID 01003
Citaton Type Other
Standard Cited 19100305 G01 III
Issuance Date 1989-01-26
Abatement Due Date 1989-02-01
Nr Instances 1
Nr Exposed 32
Gravity 02

Date of last update: 08 Apr 2025