Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-03-13
|
Emphasis |
L: FALL, L: RESCON
|
Case Closed |
2015-06-04
|
Related Activity
Type |
Referral |
Activity Nr |
811086 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 I |
Issuance Date |
2013-04-30 |
Abatement Due Date |
2013-05-02 |
Current Penalty |
1400.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-05-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. Jobsite, southwest side of structure: On or about 03/13/2013, employees were working from a Carpenters Bracket Scaffold whereby the bracket scaffold was not fully planked. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2013-04-30 |
Abatement Due Date |
2013-05-02 |
Current Penalty |
1400.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-05-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: Jobsite, southwest side of structure: On or about 03/13/2013, the employer did not ensure that the Carpenters Bracket Scaffold was inspected for visible defects before each work shift. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260451 F04 |
Issuance Date |
2013-04-30 |
Abatement Due Date |
2013-05-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-05-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired. Jobsite, southwest side of structure: On or about 03/13/2013, employees were working from a Carpenters Bracket Scaffold whereby the planking had numerous defects affecting the strength of the plank. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2013-04-30 |
Abatement Due Date |
2013-05-02 |
Current Penalty |
1400.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-05-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. Jobsite, southeast corner of structure: On or about 03/13/2013, an employee was performing construction activities from a Carpenters Bracket Scaffold greater than 10 feet from the floor of the bulkhead and was not protected by a guardrail system, net system, or personal fall protection. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260503 B01 |
Issuance Date |
2013-04-30 |
Abatement Due Date |
2013-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-05-14 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. Establishment: On or about 03/13/2013, where employees are exposed to fall hazards the employer did not verify compliance with the training requirements of this section by preparing a written certification record for each employee affected. |
|
|