Search icon

Homestead Baking Co.

Company Details

Name: Homestead Baking Co.
Jurisdiction: Rhode Island
Entity type: Domestic Profit Corporation
Status: Activ
Date of Organization in Rhode Island: 24 May 1920 (105 years ago)
Identification Number: 000017496
ZIP code: 02916
County: Providence County
Principal Address: 145 N BROADWAY, RUMFORD, RI, 02916, USA
Purpose: WHOLESALE BAKERY
NAICS: 311812 - Commercial Bakeries
Fictitious names: MRS. KAVANAGH'S ENGLISH MUFFINS (trading name, 2008-10-22 - )
Historical names: Hellenic Baking Company

Agent

Name Role Address
WILLIAM P. VICAN, JR. Agent 145 NORTH BROADWAY, RUMFORD, RI, 02916, USA

PRESIDENT

Name Role Address
PETER VICAN PRESIDENT 95 HAMILTON DR. EAST GREENWICH, RI 02818 USA

VICE PRESIDENT

Name Role Address
THEODORE PASCALIDES VICE PRESIDENT 40 ARNOLD AVE JAMESTOWN, RI 02835 USA

DIRECTOR

Name Role Address
PETER VICAN DIRECTOR 95 HAMILTON DR. EAST GREENWICH, RI 02818 USA
THEODORE PASCALIDES DIRECTOR 40 ARNOLD AVE JAMESTOWN, RI 02835 USA

Events

Type Date Old Value New Value
Name Change 1949-12-05 Hellenic Baking Company Homestead Baking Co.

Filings

Number Name File Date
202444545950 Annual Report 2024-01-23
202326934740 Annual Report 2023-01-31
202208804930 Annual Report 2022-01-28
202187434450 Annual Report 2021-01-20
202033316710 Annual Report 2020-01-29
201912494130 Annual Report 2019-08-15
201906959340 Revocation Notice For Failure to File An Annual Report 2019-07-24
201857894510 Annual Report 2018-02-08
201737191580 Annual Report 2017-03-02
201589082630 Annual Report 2015-12-12

USAspending Awards. Contracts

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
PO AWARD V650X80002 2007-11-06 2007-11-30 2007-11-30
Unique Award Key CONT_AWD_V650X80002_3600_-NONE-_-NONE-
Awarding Agency Department of Veterans Affairs
Link View Page

Description

Title ROLL, GRINDER, FRESH, 6", 15 OZ PG
Product and Service Codes 8920: BAKERY AND CEREAL PRODUCTS

Recipient Details

Recipient HOMESTEAD BAKING CO.
UEI XCMKQ5EK44M5
Legacy DUNS 001200542
Recipient Address 145 N BROADWAY, RUMFORD, 029162801, UNITED STATES
PO AWARD V650X80001 2007-10-03 2007-10-31 2007-10-31
Unique Award Key CONT_AWD_V650X80001_3600_-NONE-_-NONE-
Awarding Agency Department of Veterans Affairs
Link View Page

Description

Title ROLL, GRINDER, FRESH, 6", 15 OZ PG
Product and Service Codes 8920: BAKERY AND CEREAL PRODUCTS

Recipient Details

Recipient HOMESTEAD BAKING CO.
UEI XCMKQ5EK44M5
Legacy DUNS 001200542
Recipient Address 145 N BROADWAY, RUMFORD, 029162801, UNITED STATES

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347433989 0112300 2024-04-24 145 NORTH BROADWAY, RUMFORD, RI, 02916
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2024-04-24
Emphasis P: AMPUTATE, N: AMPUTATE, L: FORKLIFT, L: EISAOF
Case Closed 2024-07-26

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100219 C02 I
Issuance Date 2024-06-27
Current Penalty 6388.8
Initial Penalty 10648.0
Final Order 2024-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting. a) Pan Feed Conveyor: On or about 4/24/2024, employees were exposed to the rotating shaft associated with an unguarded pan conveyor system.
344307061 0112300 2019-09-13 145 N BROADWAY, RUMFORD, RI, 02916
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-09-13
Emphasis L: EISAOF, L: FORKLIFT, L: R1Noise, N: AMPUTATE, P: AMPUTATE
Case Closed 2019-12-16

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100219 C04 I
Issuance Date 2019-11-26
Abatement Due Date 2019-12-20
Current Penalty 2652.0
Initial Penalty 5304.0
Final Order 2019-12-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft. a) Main building of operations: on or about 9/13/2019, the employer did not ensure to cover a projecting shaft ends on the end-product manufacturing line.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100219 F03
Issuance Date 2019-11-26
Abatement Due Date 2019-12-20
Current Penalty 0.0
Initial Penalty 5304.0
Final Order 2019-12-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed. a) Main building of operations: on or about 9/13/2019, the employer did not ensure to enclose two sprocket wheels and two chains on the English muffin shaker.
343162004 0112300 2018-05-16 145 NORTH BROADWAY, EAST PROVIDENCE, RI, 02916
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-05-16
Emphasis N: AMPUTATE
Case Closed 2018-06-26

Related Activity

Type Referral
Activity Nr 1337960
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2018-06-08
Current Penalty 4979.0
Initial Penalty 7114.0
Final Order 2018-06-20
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Worksite: On or about 5/12/2018, the employer did not ensure that the Panomat machine was guarded to prevent employee exposures from an ingoing nip point where rollers process dough balls.
342039120 0112300 2017-01-20 145 N BROADWAY, RUMFORD, RI, 02916
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-01-20
Emphasis N: AMPUTATE
Case Closed 2017-04-21

Related Activity

Type Referral
Activity Nr 1174448
Safety Yes
339678773 0112300 2014-04-14 145 N BROADWAY, RUMFORD, RI, 02916
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-04-22
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2014-05-27

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100178 M05 I
Issuance Date 2014-05-02
Abatement Due Date 2014-05-27
Current Penalty 0.0
Initial Penalty 2310.0
Final Order 2014-05-22
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(m)(5)(i): When a powered industrial truck was left unattended, load engaging means were not fully lowered, controls were not neutralized, power was not shut off, and brakes were not set: (a) Facility: The parking brake of the Komatsu propane powered industrial truck was not set while the truck was unattended, on or about 4-14-14.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2014-05-02
Abatement Due Date 2014-05-27
Current Penalty 1540.0
Initial Penalty 3080.0
Final Order 2014-05-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: (a) 2nd cellar machine shop: The unused portion of the rotating blade of the Kalamazoo horizontal band saw was not guarded by an adequate guard or guarding device, on or about 4-14-14.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100212 B
Issuance Date 2014-05-02
Abatement Due Date 2014-05-27
Current Penalty 1155.0
Initial Penalty 2310.0
Final Order 2014-05-22
Nr Instances 2
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) 2nd cellar machine shop: The 12 speed drill press used in the machine shop was not securely anchored to prevent walking or moving, on or about 4-14-14. (b) 2nd cellar machine shop: The Delta 6 inch pedestal grinder used in the machine shop was not securely anchored to prevent walking or moving, on or about 4-14-14.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2014-05-02
Abatement Due Date 2014-05-27
Current Penalty 1155.0
Initial Penalty 2310.0
Final Order 2014-05-22
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch: (a) 2nd cellar machine shop: The distance between the abrasive wheel periphery and the adjustable tongue at the top of the Delta 6 inch Pedistal Grinder was five-eighths inch, and thus exceeded one-fourth inch, on or about 4-14-14.
Citation ID 02001
Citaton Type Other
Standard Cited 19100305 G02 III
Issuance Date 2014-05-02
Abatement Due Date 2014-05-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-22
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) 2nd cellar machine shop: The power cord on the Kalamazoo horizontal band saw was not provided with an adequate tension relief device at the point the cord entered the junction box on the saw, on or about 4-14-14.