Search icon

PRECISION TURNED COMPONENTS CORP.

Company Details

Name: PRECISION TURNED COMPONENTS CORP.
Jurisdiction: Rhode Island
Entity type: Domestic Profit Corporation
Status: Activ
Date of Organization in Rhode Island: 31 Oct 1980 (44 years ago)
Identification Number: 000015833
ZIP code: 02917
County: Providence County
Principal Address: 331 FARNUM PIKE, SMITHFIELD, RI, 02917, USA
Purpose: MANUFACTURER OF MICROWAVE CONNECTOR PARTS
Fictitious names: SYLVESTRE SCREW MACHINE CO., INC. (trading name, 1988-03-07 - )
Historical names: SYLVESTRE SCREW MACHINE CO., INC.

Industry & Business Activity

NAICS

332721 Precision Turned Product Manufacturing

This U.S. industry comprises establishments known as precision turned manufacturers primarily engaged in machining precision products of all materials on a job or order basis. Generally precision turned product jobs are large volume using machines, such as automatic screw machines, rotary transfer machines, computer numerically controlled (CNC) lathes, or turning centers. Learn more at the U.S. Census Bureau

Commercial and government entity program

CAGE number Status Type Established CAGE Update Date CAGE Expiration SAM Expiration
1ZF78 Active U.S./Canada Manufacturer 2002-07-19 2024-04-02 2029-04-02 2025-04-01

Contact Information

POC SCOT JONES
Phone +1 401-232-3377
Fax +1 401-232-3253
Address 331 FARNUM PIKE, SMITHFIELD, RI, 02917 1205, UNITED STATES

Ownership of Offeror Information

Highest Level Owner Information not Available
Immediate Level Owner
Vendor Certified 2024-04-02
CAGE number 73957
Company Name GROOV-PIN CORPORATION
CAGE Last Updated 2024-06-10
List of Offerors (0) Information not Available

PRESIDENT

Name Role Address
SCOT A JONES PRESIDENT 331 FARNUM PIKE SMITHFIELD, RI 02917- USA

Agent

Name Role Address
SCOT A. JONES Agent 331 FARNUM PIKE, SMITHFIELD, RI, 02917, USA

Events

Type Date Old Value New Value
Name Change 1988-07-07 SYLVESTRE SCREW MACHINE CO., INC. PRECISION TURNED COMPONENTS CORP.

Filings

Number Name File Date
202445278460 Annual Report 2024-02-01
202327201210 Annual Report 2023-02-01
202221201910 Annual Report 2022-07-13
202219988500 Revocation Notice For Failure to File An Annual Report 2022-06-27
202197866870 Annual Report 2021-06-07
202196730730 Revocation Notice For Failure to File An Annual Report 2021-05-19
202032509780 Annual Report 2020-01-16
201987213780 Annual Report 2019-02-21
201860063550 Annual Report 2018-03-12
201729726800 Annual Report 2017-01-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347070195 0112300 2023-10-31 331 FARNUM PIKE, SMITHFIELD, RI, 02917
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2023-10-31

Related Activity

Type Inspection
Activity Nr 1704714
Safety Yes
Type Referral
Activity Nr 2095622
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2024-03-22
Abatement Due Date 2024-07-01
Current Penalty 5646.0
Initial Penalty 11292.0
Final Order 2024-04-30
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Back Finishing Area of the Establishment: On or about October 31, 2023, an employee was engaged in cleaning and degreasing metal parts using Safety-Kleen Premium Solvent while wearing a 3M Half-Face Organic Vapor respirator when the employer had not developed nor implemented a written respiratory protection program.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 D01 III
Issuance Date 2024-03-22
Abatement Due Date 2024-07-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-04-30
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(iii):The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (a) Back Finishing Area of the Establishment: On or about October 31, 2023 the employer did not identify and evaluate employee exposure while they are performing cleaning and degreasing of metal parts using Safety-Kleen Premium Solvent.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2024-03-22
Abatement Due Date 2024-07-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-04-30
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Back Finishing Area of the Establishment: On or about October 31, 2023 an employee was performing cleaning and degreasing metal parts work using Safety-Kleen Premium Solvent while wearing a 3M Half-Face Organic Vapor respirator and the employer had not provided a medical evaluation.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100134 F01
Issuance Date 2024-03-22
Abatement Due Date 2024-07-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-04-30
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) Back Finishing Area of the Establishment: On or about October 31, 2023, the employer did not conduct fit testing for an employee wearing a 3M Half-Face Organic Vapor respirator when engaged in cleaning and degreasing metal parts using Safety-Kleen Premium Solvent.
347047144 0112300 2023-10-20 331 FARNUM PIKE, SMITHFIELD, RI, 02917
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-10-20
Emphasis N: AMPUTATE, P: AMPUTATE

Related Activity

Type Inspection
Activity Nr 1707019
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C06 II
Issuance Date 2024-03-22
Abatement Due Date 2024-07-31
Current Penalty 2823.0
Initial Penalty 11292.0
Final Order 2024-04-30
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection: a) Facility On or about 10/20/23, the employer did not conduct an adequate periodic inspection certifications of energy control procedures containing the required documentation on the identification of machine or equipment such as but not limited to, the Davenport D16, Multi-Spindle M4, Gildemeister Machine GM16, Escomatic E3 and Miyano MTV-C310, #2. Energy sources include pneumatic, electrical and hydraulic. To also include the inspection date, employees included, and the person performing the inspection of the employees perform energy control procedures:
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2024-03-22
Abatement Due Date 2025-03-03
Current Penalty 7904.0
Initial Penalty 11292.0
Final Order 2024-04-30
Nr Instances 11
Nr Exposed 9
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Davenport Department: On or about 10/20/23, the employer did not ensure that employees were protected by adequate machine guarding methods in that Machine D11 was operating with the two door guards in the opened position and the rotating pusher tubes were unguarded. b) Davenport Department: On or about 10/20/23, the employer did not ensure that employees were protected by adequate machine guarding methods in that Machine D13 was operating with one of the door guards in the opened position and the rotating pusher tubes were unguarded. c) Davenport Department: On or about 10/20/23, the employer did not ensure that employees were protected by adequate machine guarding methods in that the Davenport Model B, Machine D16, was operating with the door guard in the opened position. d) Multi-Spindle Department: On or about 10/20/23, the employer did not ensure that employees were protected by adequate machine guarding methods in that Machine M4 was operating with two door guards in the opened position and the rotating pusher tubes were unguarded. e) Gildemeister Department: On or about 10/20/23, the employer did not ensure that employees were protected by adequate machine guarding methods in that machine GM16 was operating with one door guard open. The machine was cut so that a part chute could be installed, but the addition of the chute prevented the door guard from closing completely. f) Escomatic Department: On or about 10/20/23, the employer did not ensure that employees were protected by adequate machine guarding methods in that the Escomatic E3 had exposed moving parts, such as the spinning wire stringer, rotating shafts, and wire guides, exposing employees performing quality control checks to these various moving parts. g) Escomatic Department: On or about 10/20/23, the employer did not ensure that employees were protected by adequate machine guarding methods in that the Escomatic E8 had exposed moving parts, such as the spinning wire stringer, rotating shafts, and wire guides, exposing employees performing quality control checks to these various moving parts. h) Escomatic Department: On or about 10/20/23, the employer did not ensure that employees were protected by adequate machine guarding methods in that the Escomatic E9 had exposed moving parts, such as the spinning wire stringer, rotating shafts, and wire guides. i) Escomatic Department: On or about 10/20/23, the employer did not ensure that employees were protected by adequate machine guarding methods in that the Escomatic E10 had exposed moving parts, such as the spinning wire stringer, rotating shafts, and wire guides. j) Miyano Department: On or about 10/20/2023, the employer did not ensure that employees were protected by adequate machine guarding methods in that the Walker-Turner drill press was not equipped with a chuck guard and protection from flying chips and sparks. k) Miyano Department: On or about 10/20/2023, the employer did not ensure that employees were protected by adequate machine guarding methods in that the Miyano MTV-C310, #2, was not equipped with door guard interlocks.
300099702 0112300 1999-02-08 331 FARNUM PIKE, SMITHFIELD, RI, 02917
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 1999-02-11
Emphasis L: XEISA, S: AMPUTATIONS
Case Closed 1999-03-30

Related Activity

Type Referral
Activity Nr 200094175
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 1999-02-24
Abatement Due Date 1999-03-31
Current Penalty 437.5
Initial Penalty 875.0
Nr Instances 1
Nr Exposed 20
Gravity 03
Citation ID 02001
Citaton Type Other
Standard Cited 19100095 D01
Issuance Date 1999-02-24
Abatement Due Date 1999-04-28
Nr Instances 1
Nr Exposed 10
Gravity 01

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
9590638503 2021-03-12 0165 PPS 331 Farnum Pike, Smithfield, RI, 02917-1205
Loan Status Date 2021-12-16
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 516825
Loan Approval Amount (current) 516825
Undisbursed Amount 0
Franchise Name -
Lender Location ID 9551
Servicing Lender Name Bank of America, National Association
Servicing Lender Address 100 N Tryon St, Ste 170, CHARLOTTE, NC, 28202-4024
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Smithfield, PROVIDENCE, RI, 02917-1205
Project Congressional District RI-01
Number of Employees 40
NAICS code 332721
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 9551
Originating Lender Name Bank of America, National Association
Originating Lender Address CHARLOTTE, NC
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 520110.02
Forgiveness Paid Date 2021-11-03
5822397705 2020-05-01 0165 PPP 331 FARNUM PIKE, SMITHFIELD, RI, 02917-1205
Loan Status Date 2021-04-16
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 516825
Loan Approval Amount (current) 516825
Undisbursed Amount 0
Franchise Name -
Lender Location ID 9551
Servicing Lender Name Bank of America, National Association
Servicing Lender Address 100 N Tryon St, Ste 170, CHARLOTTE, NC, 28202-4024
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description New Business or 2 years or less
Project Address SMITHFIELD, PROVIDENCE, RI, 02917-1205
Project Congressional District RI-01
Number of Employees 47
NAICS code 332721
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 9551
Originating Lender Name Bank of America, National Association
Originating Lender Address CHARLOTTE, NC
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 521455.19
Forgiveness Paid Date 2021-03-25

U.S. Small Business Administration Profile

Status User ID Name of Firm Trade Name UEI Address
Active P0277893 PRECISION TURNED COMPONENTS CORP - WGJEXJS4AFU9 331 FARNUM PIKE, SMITHFIELD, RI, 02917-1205
Capabilities Statement Link -
Phone Number 401-232-3377
Fax Number 401-232-3253
E-mail Address sjones@groov-pin.com
WWW Page http://www.groov-pin.com
E-Commerce Website -
Contact Person SCOT JONES
County Code (3 digit) 007
Congressional District 01
Metropolitan Statistical Area 6480
CAGE Code 1ZF78
Year Established 1980
Accepts Government Credit Card Yes
Legal Structure Corporation
Ownership and Self-Certifications Self-Certified Small Disadvantaged Business
Business Development Servicing Office RHODE ISLAND DISTRICT OFFICE (SBA office code 0165)
Capabilities Narrative (none given)
Special Equipment/Materials (none given)
Business Type Percentages (none given)
Keywords (none given)
Quality Assurance Standards (none given)
Electronic Data Interchange capable -

SBA Federal Certifications

HUBZone Certified No
Women Owned Certified No
Women Owned Pending No
Economically Disadvantaged Women Owned Certified No
Economically Disadvantaged Women Owned Pending No
Veteran-Owned Small Business Certified No
Veteran-Owned Small Business Joint Venture No
Service-Disabled Veteran-Owned Small Business Certified No
Service-Disabled Veteran-Owned Small Business Joint Venture No

Bonding Levels

Description Construction Bonding Level (per contract)
Level $0
Description Construction Bonding Level (aggregate)
Level $0
Description Service Bonding Level (per contract)
Level $0
Description Service Bonding Level (aggregate)
Level $0

NAICS Codes with Size Determinations by NAICS

Primary Yes
Code 332721
NAICS Code's Description Precision Turned Product Manufacturing
Buy Green Yes
Code 332722
NAICS Code's Description Bolt, Nut, Screw, Rivet and Washer Manufacturing
Buy Green Yes

Export Profile (Trade Mission Online)

Exporter Firm hasn't answered this question yet
Export Business Activities (none given)
Exporting to (none given)
Desired Export Business Relationships (none given)
Description of Export Objective(s) (none given)

Date of last update: 06 Apr 2025

Sources: Rhode Island Department of State