347390940
|
0112300
|
2024-04-04
|
303 ALLENS AVENUE, PROVIDENCE, RI, 02905
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-04-04
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2024-08-30
|
Related Activity
Type |
Complaint |
Activity Nr |
2147281 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1739162 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1653516 |
Safety |
Yes |
|
|
347391625
|
0112300
|
2024-04-04
|
303 ALLENS AVENUE, PROVIDENCE, RI, 02905
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2024-04-04
|
Case Closed |
2024-08-26
|
Related Activity
Type |
Complaint |
Activity Nr |
2147281 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1654821 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1739094 |
Safety |
Yes |
|
|
346548217
|
0112300
|
2023-03-08
|
303 ALLENS AVENUE, PROVIDENCE, RI, 02905
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2023-03-08
|
Emphasis |
L: R1Noise
|
Related Activity
Type |
Referral |
Activity Nr |
2007147 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1653516 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100107 B05 I |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
5578.2 |
Initial Penalty |
9297.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(5)(i): The average air speed over the open face of the paint spray booth was less than 100 linear feet per minute. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the cross-section air velocity of the paint booth was measured and calculated to be 48.3 linear feet per minute, exposing employees to a flammable vapor hazard while spray painting in the booth with paints including, but not limited to, modified acrylic alkyd enamel and Red Insulating Varnish. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100107 B09 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not ensure that a clear space of 3 feet or more on all sides was kept free from storage or combustible construction to allow access for cleaning. A flammable storage locker was inches from the right exterior side of the paint booth and a plywood box was stored along the right interior side of the booth which prevented cleaning of the floor and filters. There was also a plastic kids pool on top of the paint booth. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100107 F03 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(f)(3): Sprinklers protecting spraying areas were not kept as free from deposits as practical by cleaning daily if necessary. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not ensure that sprinklers protecting spraying areas were kept as free from deposits as practical. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100107 G02 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not keep the walls, ceiling and floor of the paint booth free from the accumulation of deposits of combustible residues. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100134 C02 II |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
3187.8 |
Initial Penalty |
5313.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not establish and implement an adequate written respiratory protection program to ensure that employees are medically able to voluntarily use elastomeric and filtering facepiece respirators while performing tasks, including but not limited to, spray painting with hazardous chemicals. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100134 C03 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(3): The employer did not designate a program administrator who was qualified by appropriate training or experience to administer or oversee the respiratory protection program and to conduct the required evaluations of program effectiveness. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not designate a qualified program administrator to administer or oversee the respiratory protection program for employees that use elastomeric respirators and filtering facepieces (N95) in the workplace. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not provide a medical evaluation to determine the employee's ability to use an elastomeric respirator while performing tasks, including but not limited to, spray painting using hazardous chemicals. |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19100134 D01 III |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not provide a medical evaluation to determine the employee's ability to use an elastomeric respirator while performing tasks, including but not limited to, spray painting with hazardous chemicals. |
|
Citation ID |
01002E |
Citaton Type |
Serious |
Standard Cited |
19100134 K06 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not present the basic advisory information in Appendix D of 29 CFR 1910.134, to employees who wear elastomeric and N95 respirators voluntarily. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 I |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
4781.4 |
Initial Penalty |
7969.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not maintain a complete list of current hazardous chemicals used at the facility, including but not limited to, Aerochem Red Insulating Varnish, an extremely flammable aerosol and Safety-Kleen Premium Solvent, a combustible liquid that causes skin irritation. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 G01 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-09-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): The employer did not have a safety data sheet in the workplace for each hazardous chemical for which they use. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not have current safety data sheets for all hazardous chemicals in the workplace, including but not limited to, Aerochem Red Insulating Varnish, an extremely flammable aerosol and Safety-Kleen Premium Solvent, a combustible liquid that causes skin irritation. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not provide all employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment for chemicals including, but not limited to, Aerochem Red Insulating Varnish, an extremely flammable aerosol and Safety-Kleen Premium Solvent, a combustible liquid that causes skin irritation. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040041 A02 |
Issuance Date |
2023-06-12 |
Current Penalty |
796.8 |
Initial Penalty |
1328.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
73 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.41(a)(2): For establishments with 20 or more employees but fewer than 250 employees at any time during the previous calendar year in designated industries and required to keep records by this part, the employer failed to electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form. (a) Walco Electric Company located at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer failed to electronically submit information from their OSHA Form 300A or equivalent by 03/02/2023. The establishment employed 73 employees and is classified with NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance, during calendar year 2023. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100022 A01 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
447.6 |
Initial Penalty |
746.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
25 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not ensure that all places of employment, including but not limited to, the work area around the sand blasting cabinet, are kept in a clean, orderly, and sanitary condition, in that there was excessive dust and debris around the floor of the blast cabinet that was not contained or captured by the dust collection system. A sample was taken and analyzed by SLTC (sample number 416742) and found to have lead at 0.0071%. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100132 D02 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-09-07 |
Current Penalty |
447.6 |
Initial Penalty |
746.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
25 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment. (a) Facility at 303 Allens Avenue in Providence, RI: On or about March 8, 2023, the employer did not verify that the required workplace Personal Protective Equipment hazard assessment has been performed through a written certification. |
|
|
346535164
|
0112300
|
2023-03-01
|
303 ALLENS AVENUE, PROVIDENCE, RI, 02905
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-03-01
|
Emphasis |
L: FORKLIFT, L: FALL, L: R1Noise, N: LEAD, N: AMPUTATE
|
Related Activity
Type |
Inspection |
Activity Nr |
1654821 |
Health |
Yes |
|
Type |
Referral |
Activity Nr |
2007147 |
Health |
Yes |
|
Type |
Complaint |
Activity Nr |
2011401 |
Safety |
Yes |
Health |
Yes |
|
Type |
Complaint |
Activity Nr |
2006316 |
Safety |
Yes |
Health |
Yes |
|
Type |
Referral |
Activity Nr |
2004883 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100028 B01 I |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
3187.8 |
Initial Penalty |
5313.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): a) Motor Shop: On or about 3/28/2023, and times prior, the employer permitted employees to work on a motor, at heights greater then 7 feet, without any means of fall protection. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100178 L04 II E |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
5578.2 |
Initial Penalty |
9297.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Inspection NR |
1739094 |
FTA Issuance Date |
2024-06-06 |
FTA Current Penalty |
5758.8 |
FTA Final Order Date |
2024-06-21 |
Citation text line |
29 CFR 1910.178(l)(4)(ii)(E): Refresher training was not provided to forklift operators after a condition changed that affected safe operation of the truck. a) Worksite: On or about 3/1/2023, and times prior, the employer failed to ensure forklift operators were retrained when forklift attachment use impacted safe operations. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100178 Q01 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
2 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel. a) Worksite: On or about 3/1/2023, the Toyota forklift, Model 7FGCU32, serial #65245, had not been taken out of service where three tires showed significant damage, to include cracks, splits, and missing chunks of the tire. b) Worksite: On or about 3/1/2023, the Toyota forklift, Model 7FGCU32, serial #65245, was not repaired when the load back rest broke away from the forklift carriage. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100178 Q07 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Inspection NR |
1739094 |
FTA Issuance Date |
2024-06-06 |
FTA Current Penalty |
4114.2 |
FTA Final Order Date |
2024-06-21 |
Citation text line |
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: a) Worksite: On or about 2/25/2023, and other times, the employer did not ensure powered industrial trucks were inspected prior to each Saturday shift. b) Worksite: On or about 3/1/2023, and other times, the employer did not ensure powered industrial trucks were inspected prior to use by each weekday shift. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100179 J02 III |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
4781.4 |
Initial Penalty |
7969.0 |
Final Order |
2023-07-07 |
Nr Instances |
2 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed. a) Winding Room: On or about 3/8/2023, the employer had not ensured that monthly inspections of hooks, with certification records, were conducted. b) Railroad Department: On or about 3/8/2023, the employer had not ensured that monthly inspections of hooks, with certification records, were conducted. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100179 J02 IV |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
2 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed. a) Winding Room: On or about 3/8/2023, the employer had not ensured that monthly inspections of hoist chains, with certification records, were conducted. b) Railroad Department: On or about 3/8/2023, the employer had not ensured that monthly inspections of hoist chains, with certification records, were conducted. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 I |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
3187.8 |
Initial Penalty |
5313.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i). a) Production/Storage Area: On or about 3/1/2023, the employer failed to guard exposed electrical wires, suspended from the ceiling and hanging next to a forklift. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2023-06-12 |
Current Penalty |
0.0 |
Initial Penalty |
6641.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye. a) Worksite: On or about 2/25/2023, the employer had not reported to OSHA, within 24 hours, that an employee sustained a partial finger amputation. The incident occurred on or about 2/25/2023 and OSHA was not notified until 2/28/2023. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100030 A01 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
447.6 |
Initial Penalty |
746.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.30(a)(1): The employer did not provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart before any employee is exposed to a fall hazard. And/or the employer did not ensure employees are trained in the requirements of this paragraph on or before May 17, 2017. a) Worksite: On or about 3/28/2023, the employer did not ensure that employees exposed to fall hazards were trained in fall protection. |
|
Citation ID |
02003A |
Citaton Type |
Other |
Standard Cited |
19100157 E02 |
Issuance Date |
2023-06-12 |
Current Penalty |
447.6 |
Initial Penalty |
746.0 |
Final Order |
2023-07-07 |
Nr Instances |
2 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly. a) Worksite: On or about 3/8/2023, the employer did not ensure monthly maintenance checks were being conducted on the portable fire extinguishers in the facility. |
|
Citation ID |
02003B |
Citaton Type |
Other |
Standard Cited |
19100157 G02 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
12 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter. a) Worksite: On or about 3/8/2023, the employer did not provide initial training to new employees about the use of fire extinguishers to fight incipient fires. b) Worksite: On or about 3/8/2023, the employer did not provide annual re-training to employees about the use of fire extinguishers to fight incipient fires. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100160 B07 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
447.6 |
Initial Penalty |
746.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Inspection NR |
1739094 |
FTA Issuance Date |
2024-06-06 |
FTA Current Penalty |
357.0 |
FTA Final Order Date |
2024-06-21 |
Citation text line |
29 CFR 1910.160(b)(7): The weight and pressure of refillable containers of fixed extinguishing systems were not checked at least semi-annually. a) Paint booth: On or about 3/8/2023, the employer failed to ensure that the fire suppression system on the paint booth was inspected semi-annually. |
|
Citation ID |
02005A |
Citaton Type |
Other |
Standard Cited |
19100178 A05 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
447.6 |
Initial Penalty |
746.0 |
Final Order |
2023-07-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered. a) Railroad Department: On or about 2/25/23, the employer did not ensure that a powered industrial truck with fork extenders was marked on the data plate to include the attachment modifications. |
|
Citation ID |
02005B |
Citaton Type |
Other |
Standard Cited |
19100178 A06 |
Issuance Date |
2023-06-12 |
Abatement Due Date |
2023-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-07-07 |
Nr Instances |
2 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition. a) Worksite: On or about 3/1/2023, the employer did not ensure the powered industrial truck data plate and labels were maintained on PIT #1. b) Worksite: On or about 3/1/2023, the employer did not ensure the powered industrial truck data plate and labels were maintained on PIT #2. |
|
|
300099520
|
0112300
|
1999-01-22
|
303 ALLENS AVE, PROVIDENCE, RI, 02905
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
1999-01-22
|
Emphasis |
L: XEISA
|
Case Closed |
1999-05-26
|
Related Activity
Type |
Referral |
Activity Nr |
200094118 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100304 F05 V |
Issuance Date |
1999-01-28 |
Abatement Due Date |
1999-02-02 |
Current Penalty |
1137.5 |
Initial Penalty |
2275.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
05 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100334 A02 I |
Issuance Date |
1999-01-28 |
Abatement Due Date |
1999-02-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
05 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C04 II |
Issuance Date |
1999-01-28 |
Abatement Due Date |
1999-05-03 |
Nr Instances |
1 |
Nr Exposed |
50 |
Gravity |
01 |
|
|
300093176
|
0112300
|
1997-05-05
|
303 ALLENS AVE, PROVIDENCE, RI, 02905
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1997-08-19
|
Emphasis |
L: NPHIHAZ
|
Case Closed |
1997-09-11
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100106 D03 II |
Issuance Date |
1997-08-19 |
Abatement Due Date |
1997-08-25 |
Current Penalty |
412.5 |
Initial Penalty |
825.0 |
Nr Instances |
3 |
Nr Exposed |
5 |
Gravity |
01 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100107 E02 |
Issuance Date |
1997-08-19 |
Abatement Due Date |
1997-08-25 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
1997-08-19 |
Abatement Due Date |
1997-08-25 |
Current Penalty |
550.0 |
Initial Penalty |
1100.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
1997-08-19 |
Abatement Due Date |
1997-08-25 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100219 E01 I |
Issuance Date |
1997-08-19 |
Abatement Due Date |
1997-08-25 |
Current Penalty |
550.0 |
Initial Penalty |
1100.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 A01 |
Issuance Date |
1997-08-19 |
Abatement Due Date |
1997-08-25 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
00 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100157 C01 |
Issuance Date |
1997-08-19 |
Abatement Due Date |
1997-08-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
00 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100178 P01 |
Issuance Date |
1997-08-19 |
Abatement Due Date |
1997-08-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100212 B |
Issuance Date |
1997-08-19 |
Abatement Due Date |
1997-08-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
00 |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19100303 B02 |
Issuance Date |
1997-08-19 |
Abatement Due Date |
1997-08-25 |
Nr Instances |
1 |
Gravity |
01 |
|
|