Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2014-02-13
|
Emphasis |
L: EISAOF, P: R1NOISE, L: R1NOISE
|
Case Closed |
2014-05-19
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100036 D01 |
Issuance Date |
2014-04-11 |
Abatement Due Date |
2014-04-21 |
Current Penalty |
1500.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-05-06 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) Exit door adjacent to Barrel Department on north side of building: On or about 2-4-14 the exit route door was secured with a latch that required special knowledge to open. |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 I |
Issuance Date |
2014-04-11 |
Abatement Due Date |
2014-05-27 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-05-06 |
Nr Instances |
1 |
Nr Exposed |
7 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet: (a) Workplace: On or about 2/4/14 the employer did not maintain a listing of the hazardous chemicals known to be present in the workplace. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19101200 F05 |
Issuance Date |
2014-04-11 |
Abatement Due Date |
2014-05-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-06 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: (a) Rack Department: On or about 2/4/14 electroplating baths, including nickel and gold plating baths, were not adequately labeled, tagged or marked with the identity and appropriate hazard warnings. b) Barrel Department: On or about 2/4/14 electroplating baths, including nickel plating baths, and the waste tank were not adequately labeled, tagged or marked with the identity and appropriate hazard warnings. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 H03 IV |
Issuance Date |
2014-04-11 |
Abatement Due Date |
2014-05-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-06 |
Nr Instances |
1 |
Nr Exposed |
7 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; and the safety data sheet, including the order of information and how employees could obtain and use the appropriate hazard information: (a) Workplace: On or about 2/4/14 the employer had not trained employees on the new hazardous material label elements and the new safety data sheet format. |
|
|