347750127
|
0112300
|
2024-09-12
|
245 CAROLINA AVENUE, PROVIDENCE, RI, 02905
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2024-09-12
|
Emphasis |
L: R1Noise, P: R1Noise
|
Case Closed |
2024-09-12
|
|
347533622
|
0112300
|
2024-06-04
|
245 CAROLINA AVENUE, PROVIDENCE, RI, 02905
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2024-06-04
|
Emphasis |
N: CHROME6
|
Related Activity
Type |
Complaint |
Activity Nr |
2167854 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100134 D01 III |
Issuance Date |
2024-11-21 |
Abatement Due Date |
2025-02-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (a) Dipping Operations: On or about June 4, 2024, the employer did not identify and evaluate the respiratory hazard(s) in the workplace, including a reasonable estimate of employee exposures to respiratory hazards from dipping chemicals including acid mists and metals including hexavalent chromium. ABATEMENT NOTE: In accordance with 29 CFR 1910.134(d)(1)(iii), the employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. When conditions in the workplace change, including changes to the ventilation system the employer shall re-evaluate employee exposures. Guidance on evaluating respirable hazards in the workplace is available in OSHA Small Entity Compliance Guide for the Respiratory Protection Standard. This document is available on the internet at the following website address: Small Entity Compliance Guide for the Respiratory Protection Standard (osha.gov) https://www.osha.gov/sites/default/files/publications/3384small-entity-for-respiratory-protection-standard-rev.pdf |
|
|
342163037
|
0112300
|
2017-03-09
|
245 CAROLINA AVE, PROVIDENCE, RI, 02905
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-05-10
|
Emphasis |
L: EISAOF, N: CHROME6, P: CHROME6
|
Case Closed |
2018-04-24
|
Related Activity
Type |
Inspection |
Activity Nr |
1219136 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100132 A |
Issuance Date |
2017-05-12 |
Abatement Due Date |
2017-06-15 |
Current Penalty |
1738.0 |
Initial Penalty |
2897.0 |
Final Order |
2017-06-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(a): Protective equipment was not maintained in a sanitary and reliable condition: (a) Anodizing Room: On or about 3-9-17, protective equipment, such as safety glasses and rubber gloves, was not maintained in a sanitary condition. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100132 D02 |
Issuance Date |
2017-05-12 |
Abatement Due Date |
2017-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-06-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment had been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2): (a) Workplace: On or about 3/9/17 the employer had not certified that the required workplace hazard assessment for personal protective equipment needs had been performed. Abatement Note: Once the PPE Hazard Assessment is completed you shall: 1) Certify that the hazard assessment has been performed through a written certification in accordance with 1910.132 (d) (2), 2) Provide training to affected employees in proper use of required PPE (1910.132 (f) (1)), and Guidance on conducting and documenting a PPE Hazard Assessment can be found on OSHA's website at: http://www.osha.gov/SLTC/personalprotectiveequipment/ |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2017-05-12 |
Abatement Due Date |
2017-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-06-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: (a) Anodizing Room: On or about 3-9-17 the employer did not provide appropriate eye and face protection (face shields and chemical goggles) for employees working with corrosive chemicals. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100138 A |
Issuance Date |
2017-05-12 |
Abatement Due Date |
2017-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-06-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees hands were exposed to hazardous condition(s): (a) Racking and Shipping Department: On or about 3-9-17 the employer did not require that employees handling contaminated racking wear chemically resistant gloves. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2017-05-12 |
Abatement Due Date |
2017-06-15 |
Current Penalty |
1738.0 |
Initial Penalty |
2897.0 |
Final Order |
2017-06-06 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Workplace: On or about 3-9-17 the employer did not have a written hazard communication program. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19101200 F06 |
Issuance Date |
2017-05-12 |
Abatement Due Date |
2017-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-06-06 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: (a) Anodizing Room: On or about 3/9/17 the employer did not ensure that secondary containers including anodizing and chromate coating containers were labeled with the required information. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2017-05-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-06-06 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required safety data sheets for each hazardous chemical in the workplace: (a) Anodizing Room: On or about 3-9-17 the employer did not have available the required safety data sheets for several hazardous chemicals including the SC0592 desmuttering material from Henkel Surface Technologies. |
|
|
101140655
|
0112300
|
1986-08-06
|
245 CAROLINA AVENUE, PROVIDENCE, RI, 02905
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
1986-08-13
|
Case Closed |
1986-12-30
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100132 A |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-10-21 |
Current Penalty |
160.0 |
Initial Penalty |
160.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-10-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-10-21 |
Nr Instances |
5 |
Nr Exposed |
3 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-12-02 |
Current Penalty |
150.0 |
Initial Penalty |
150.0 |
Nr Instances |
8 |
Nr Exposed |
3 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 I |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-12-02 |
Nr Instances |
8 |
Nr Exposed |
3 |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19101200 F04 I |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-12-02 |
Nr Instances |
8 |
Nr Exposed |
3 |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19101200 F04 II |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-12-02 |
Nr Instances |
8 |
Nr Exposed |
3 |
|
Citation ID |
01002E |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-12-02 |
Nr Instances |
8 |
Nr Exposed |
3 |
|
Citation ID |
01002F |
Citaton Type |
Serious |
Standard Cited |
19101200 H02 II |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-12-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
|
Citation ID |
01002G |
Citaton Type |
Serious |
Standard Cited |
19101200 H02 III |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-12-08 |
Nr Instances |
5 |
Nr Exposed |
3 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19030002 A01 |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-10-08 |
Nr Instances |
1 |
Nr Exposed |
24 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19040002 A |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-10-09 |
Nr Instances |
1 |
Nr Exposed |
24 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100094 D09 VIII |
Issuance Date |
1986-10-02 |
Abatement Due Date |
1986-10-09 |
Nr Instances |
2 |
Nr Exposed |
3 |
|
|